Pulse wave velocity measurement along the ulnar artery in the wrist region using a high frequency ultrasonic array

被引:2
|
作者
Benchemoul, Maxime [1 ,2 ]
Mateo, Tony [1 ]
Savery, David [1 ]
Gehin, Claudine [2 ]
Massot, Bertrand [2 ]
Ferin, Guillaume [1 ]
Vince, Philippe [1 ]
Flesch, Martin [1 ]
机构
[1] Vetmon SA, Act Probe Dept, F-37000 Tours, France
[2] Univ Lyon, INSA Lyon, ECL, CNRS,UCBL,CPE Lyon,INL,UMR5270, F-69621 Villeurbanne, France
来源
2021 43RD ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE & BIOLOGY SOCIETY (EMBC) | 2021年
关键词
Pulse wave velocity; intima-media thickness; cardiovascular diseases; arm artery disease; ultrasounds; ulnar artery; wall detection; non-invasive; ultra-fast imaging; ATHEROSCLEROSIS; VALIDATION;
D O I
10.1109/EMBC46164.2021.9629889
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A pulse wave velocity (PWV) measurement method performed above a small blood vessel using an ultrasonic probe is studied and reported in this paper. These experimentations are carried out using a high-frequency probe (14-22 MHz), allowing a high level of resolution compatible with the vessel dimensions, combined with an open research ultrasound scanner. High frame-rate (HFR) imaging (10 000 frames per second) is used for a precise PWV estimation. The measurements are performed in-vivo on a healthy volunteer. The probe is placed above the ulnar artery on the wrist in order to make longitudinal scans. In addition to conventional duplex ultrasound evaluation, the measurement of the PWV using this method at this location could strengthen the detection and diagnosis of cardiovascular diseases (CVDs), in particular for arm artery diseases (AADs). Moreover, these experimentations are also carried out within the scope of a demonstration for a potential miniaturized and wearable device (i.e., a probe with fewer elements, typically less than 32, and its associated electronics). The study has shown results coherent with expected PWV and also promising complementary results such as intima-media thickness (IMT) with spatiotemporal resolution on the order of 6.2 mu m and 0.1 ms.
引用
收藏
页码:4123 / 4127
页数:5
相关论文
共 50 条
  • [41] MEASUREMENT OF INTERNAL DIAMETER CHANGES AND PULSE WAVE VELOCITY IN FETAL DESCENDING AORTA USING THE ULTRASONIC PHASED-TRACKING METHOD IN NORMAL AND GROWTH-RESTRICTED FETUSES
    Miyashita, Susumu
    Murotsuki, Jun
    Muromoto, Jin
    Ozawa, Katsusuke
    Yaegashi, Nobuo
    Hasegawa, Hideyuki
    Kanai, Hiroshi
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2015, 41 (05): : 1311 - 1319
  • [42] Regional assessment of carotid artery pulse wave velocity using compressed sensing accelerated high temporal resolution 2D CINE phase contrast cardiovascular magnetic resonance
    Peper, Eva S.
    Strijkers, Gustav J.
    Gazzola, Katja
    Potters, Wouter V.
    Motaal, Abdallah G.
    Luirink, Ilse K.
    Hutten, Barbara A.
    Wiegman, Albert
    van Ooij, Pim
    van den Born, Bert-Jan H.
    Nederveen, Aart J.
    Coolen, Bram F.
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2018, 20
  • [43] Validity and reproducibility of arterial pulse wave velocity measurement using new device with oscillometric technique: A pilot study
    Madireddy Umamaheshwar Rao Naidu
    Budda Muralidhar Reddy
    Sridhar Yashmaina
    Amar Narayana Patnaik
    Pingali Usha Rani
    BioMedical Engineering OnLine, 4
  • [44] Validity and reproducibility of arterial pulse wave velocity measurement using new device with oscillometric technique: A pilot study
    Naidu, Madireddy Umamaheshwar Rao
    Reddy, Budda Muralidhar
    Yashmaina, Sridhar
    Patnaik, Amar Narayana
    Rani, Pingali Usha
    BIOMEDICAL ENGINEERING ONLINE, 2005, 4 (1)
  • [45] Signal Separation Using a Mathematical Model of Physiological Signals for the Measurement of Heart Pulse Wave Propagation With Array Radar
    Sakamoto, Takuya
    IEEE ACCESS, 2020, 8 (08): : 175921 - 175931
  • [46] High line-density pulse wave imaging for local pulse wave velocity estimation using motion matching: A feasibility study on vessel phantoms
    Li, Fubing
    He, Qiong
    Huang, Chengwu
    Luo, Jianwen
    2015 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2015,
  • [47] Visualization of Pulse-Wave Velocity on Arterial Wall of Mice Through High-Frequency Ultrafast Doppler Imaging
    Huang, Yu-Hsiang
    Huang, Hsin
    Chuang, Yi-Hsiang
    Mo, Fan-E
    Huang, Chih-Chung
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2023, 70 (12) : 3366 - 3372
  • [48] Modified high-resolution wavenumber analysis for detection of pulse wave velocity using coefficient of variation of arterial wall acceleration waveforms
    Nagaoka, Ryo
    Hasegawa, Hideyuki
    JOURNAL OF MEDICAL ULTRASONICS, 2020, 47 (02) : 167 - 177
  • [49] Measuring aortic pulse wave velocity using high-field cardiovascular magnetic resonance: comparison of techniques
    El-Sayed H Ibrahim
    Kevin R Johnson
    Alan B Miller
    Jean M Shaffer
    Richard D White
    Journal of Cardiovascular Magnetic Resonance, 12
  • [50] Comparison of Non-Invasive Methods for Measurement of Local Pulse Wave Velocity Using FSI-Simulations and In Vivo Data
    Swillens, Abigail
    Taelman, Liesbeth
    Degroote, Joris
    Vierendeels, Jan
    Segers, Patrick
    ANNALS OF BIOMEDICAL ENGINEERING, 2013, 41 (07) : 1567 - 1578