Nanorod-based flow estimation using a high-frame-rate photoacoustic imaging system

被引:28
|
作者
Liao, Chao-Kang [1 ]
Huang, Sheng-Wen [1 ]
Wei, Chen-Wei [1 ]
Li, Pai-Chi [1 ]
机构
[1] Natl Taiwan Univ, Dept Elect Engn, Grad Inst Biomed Elect & Bioinformat, Taipei 106, Taiwan
关键词
flow rate; high-frame-rate imaging; photoacoustic imaging; nanoparticles; nanorods;
D O I
10.1117/1.2812704
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A quantitative flow measurement method that utilizes a sequence of photoacoustic images is described. The method is based on the use of gold nanorods as a contrast agent for photoacoustic imaging. The peak optical absorption wavelength of a gold nanorod depends on its aspect ratio, which can be altered by laser irradiation (we establish a wash-in flow estimation method of this process). The concentration of nanorods with a particular aspect ratio inside a region of interest is affected by both laser-induced shape changes and replenishment of nanorods at a rate determined by the flow velocity. In this study, the concentration is monitored using a custom-designed, high-frame-rate photoacoustic imaging system. This imaging system consists of fiber bundles for wide area laser irradiation, a laser ultrasonic transducer array, and an ultrasound front-end subsystem that allows acoustic data to be acquired simultaneously from 64 transducer elements. Currently, the frame rate of this system is limited by the pulse-repetition frequency of the laser (i.e., 15 Hz). With this system, experimental results from a chicken breast tissue show that flow velocities from 0.125 to 2 mm/s can be measured with an average error of 31.3%. (C) 2007 Society of Photo-Optical Instrumentation Engineers.
引用
收藏
页数:9
相关论文
共 49 条
  • [1] Tracking in High-Frame-Rate Imaging
    Wu, Shih-Ying
    Wang, Shun-Li
    Li, Pai-Chi
    ULTRASONIC IMAGING, 2010, 32 (01) : 1 - 15
  • [2] Speckle Noise Reduction for High-Frame-Rate Imaging
    Lu, Jian-yu
    2017 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2017,
  • [3] A high frame rate photoacoustic imaging system and its applications to perfusion measurements
    Liao, Chao-Kang
    Huang, Sheng-Wen
    Wei, Chen-Wei
    Li, Pai-Chi
    PHOTONS PLUS ULTRASOUND: IMAGING AND SENSING 2006, 2006, 6086
  • [4] High-Frame-Rate 3-D Vector Flow Imaging in the Frequency Domain
    Rossi, Stefano
    Ramalli, Alessandro
    Fool, Fabian
    Tortoli, Piero
    APPLIED SCIENCES-BASEL, 2020, 10 (15):
  • [5] High-frame-rate volume imaging using sparse-random-aperture compounding
    Bernal, Miguel
    Cunitz, Bryan
    Rohrbach, Daniel
    Daigle, Ron
    PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (17)
  • [6] High-Frame-Rate Coherence Imaging of the Heart with Ultrasound Diverging Waves
    Matrone, Giulia
    Spairani, Edoardo
    Matrone, Benedetta
    Ramalli, Alessandro
    PROCEEDINGS OF THE 2020 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2020,
  • [7] Improving quality of high-frame-rate imaging with coherent and incoherent processing
    Liu, Jian-yu
    2018 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2018,
  • [8] Label-free high frame rate imaging of circulating blood clots using a dual modal ultrasound and photoacoustic system
    Das, Dhiman
    Sivasubramanian, Kathyayini
    Rajendran, Praveenbalaji
    Pramanik, Manojit
    JOURNAL OF BIOPHOTONICS, 2021, 14 (03)
  • [9] In vitro blood flow mean velocity estimation using a fast photoacoustic imaging system
    Liao, C. -K.
    Wei, W. -C.
    Huang, S. -W.
    Li, P-C
    2007 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1-6, 2007, : 852 - 855
  • [10] High-frame-rate imaging of biological samples with optoacoustic micro-tomography
    Dean-Ben, X. Luis
    Lopez-Schier, Hernan
    Razansky, Daniel
    PHOTONS PLUS ULTRASOUND: IMAGING AND SENSING 2018, 2018, 10494