Real-time D transesophageal echocardiography for the assessment of secundum atrial septal defects in children Three dimensional transesophageal echocardiography for assessment of atrial septa! defects

被引:0
作者
Kosger, Pelin [1 ]
Sulu, Ayse [1 ]
Akin, Tugcem [2 ]
Kiztanir, Hikmet [1 ]
Ucar, Birsen [1 ]
机构
[1] Eskisehir Osmangazi Univ, Fac Med, Dept Pediat Cardiol, Eskisehir, Turkey
[2] Eskisehir State Hosp, Pediat Cardiol Clin, Eskisehir, Turkey
来源
ANNALS OF CLINICAL AND ANALYTICAL MEDICINE | 2021年 / 12卷
关键词
ASD; Echocardiography; 3D TEE; Percutaneous closure; CONGENITAL HEART-DISEASE; TRANSCATHETER CLOSURE; DEVICE CLOSURE; OCCLUDER DEVICE; FEASIBILITY; EFFICACY; IMPACT;
D O I
10.4328/ACAM.20533
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aim: The need for more than one cross-section in the imaging of the atrial septum with two-dimensional (2D) echocardiography creates a limitation in determining the morphology of atrial septal defects (ASD) and negatively affects the success of the percutaneous closure procedure. In this study, measurements of ASDs and surrounding rims obtained by 3D transesophageal echocardiography (TEE) were compared with 2D TEE and angiographic balloon sizing measurements. Material and Methods: The study included 24 pediatric patients with the diagnosis of ASD who were scheduled for transcatheter defect closure. All patients underwent catheter-angiography following a detailed 2D TEE examination. Results: The data of 17 patients with optimal 3D TEE images were analyzed offline in the Q-lab. The diameter of the defects and surrounding rims, which were measured with two- and three-dimensional TEE were similar (p> 0.05). There was a strong correlation between the two measurement techniques in terms of defect diameter (r = 0.896, p <0.001). While the diameter of the defect measured by the sizing balloon was greater than that measured by 2D TEE, it was similar to that measured by 3D TEE (p <0.001, p = 0.14, respectively). There was also a strong correlation between the defect diameter measured by 3D TEE and balloon sizing diameter (r = 0.844. p <0.001). Discussion: The "en face" visualization of the atrial septum with 3D TEE provides adequate identification of the defect morphology and adjacent structures. Furthermore, reliable determination of the defect size by 3D imaging may lead to appropriate device selection without the requirement for invasive measurement techniques such as balloon sizing.
引用
收藏
页码:S301 / S305
页数:5
相关论文
共 50 条
  • [31] Clinical Value of Stereoscopic Three-dimensional Echocardiography in Assessment of Atrial Septal Defects: Feasibility and Efficiency
    王静
    王新房
    谢明星
    贺林
    吕清
    王蕾
    Current Medical Science, 2009, (06) : 791 - 794
  • [32] Three-dimensional echocardiographic assessment of atrial septal defects
    German, Charles
    Nanda, Navin C.
    ANNALS OF CARDIAC ANAESTHESIA, 2015, 18 (01) : 69 - 73
  • [33] Real-Time Three-Dimensional Transesophageal Echocardiography of the Left Atrial Appendage: Initial Experience in the Clinical Setting
    Shah, Sanjiv J.
    Bardo, Dianna M. E.
    Sugeng, Lissa
    Weinert, Lynn
    Lodato, Joseph A.
    Knight, Bradley P.
    Lopez, John J.
    Lang, Roberto M.
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2008, 21 (12) : 1362 - 1368
  • [34] Optimization of ASD Assessment using Real Time Three-Dimensional Transesophageal Echocardiography
    Skolnick, Adam
    Vavas, Eleni
    Kronzon, Itzhak
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2009, 26 (02): : 233 - 235
  • [35] Utility of intraoperative transesophageal echocardiography in the assessment of residual cardiac defects
    Rosenfeld, HM
    Gentles, TL
    Wernovsky, G
    Laussen, PC
    Jonas, RA
    Mayer, JE
    Colan, SD
    Sanders, SP
    van der Velde, ME
    PEDIATRIC CARDIOLOGY, 1998, 19 (04) : 346 - 351
  • [36] Experience with use of multiplane transesophageal echocardiography to guide closure of atrial septal defects using the Amplatzer device
    Figueroa, MI
    Balaguru, D
    McClure, C
    Kline, CH
    Radtke, NAK
    Shirali, GS
    PEDIATRIC CARDIOLOGY, 2002, 23 (04) : 430 - 436
  • [37] Percutaneous Closure of an Atrial Septal Defect Guided by Live Three-Dimensional Transesophageal Echocardiography
    Bhan, Amit
    Kapetanakis, Stamatis
    Pearson, Peter
    Dworakowski, Rafal
    Monaghan, M. J.
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2009, 22 (06) : 753.e1 - 753.e3
  • [38] Three-Dimensional Echocardiography Guided Closure of Complex Multiple Atrial Septal Defects
    Kijima, Yasufumi
    Akagi, Teiji
    Nakagawa, Koji
    Takaya, Yoichi
    Oe, Hiroki
    Ito, Hiroshi
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2014, 31 (10): : E304 - E306
  • [39] Three-Dimensional Transesophageal Echocardiography of Atrial Septal Defect: A Qualitative and Quantitative Anatomic Study
    Roberson, David A.
    Cui, Wei
    Patel, Dhaval
    Tsang, Wendy
    Sugeng, Lissa
    Weinert, Lynn
    Bharati, Saroja
    Lang, Roberto M.
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2011, 24 (06) : 600 - 610
  • [40] Assessment of atrial septal defects in adults comparing cardiovascular magnetic resonance with transoesophageal echocardiography
    Teo, Karen Sl
    Disney, Patrick J.
    Dundon, Benjamin K.
    Worthley, Matthew I.
    Brown, Michael A.
    Sanders, Prashanthan
    Worthley, Stephen G.
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2010, 12