Holographic pixel super-resolution in portable lensless on-chip microscopy using a fiber-optic array

被引:236
作者
Bishara, Waheb [1 ]
Sikora, Uzair [1 ]
Mudanyali, Onur [1 ]
Su, Ting-Wei [1 ]
Yaglidere, Oguzhan [1 ]
Luckhart, Shirley [2 ]
Ozcan, Aydogan [1 ,3 ]
机构
[1] Univ Calif Los Angeles, Dept Elect Engn, Los Angeles, CA 90095 USA
[2] Univ Calif Davis, Dept Med Microbiol & Immunol, Davis, CA 95616 USA
[3] Univ Calif Los Angeles, CNSI, Los Angeles, CA 90095 USA
基金
美国国家科学基金会;
关键词
UNDERSAMPLED IMAGES; REGISTRATION;
D O I
10.1039/c0lc00684j
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We report a portable lensless on-chip microscope that can achieve < 1 mu m resolution over a wide field-of-view of similar to 24 mm(2) without the use of any mechanical scanning. This compact on-chip microscope weighs similar to 95 g and is based on partially coherent digital in-line holography. Multiple fiber-optic waveguides are butt-coupled to light emitting diodes, which are controlled by a low-cost micro-controller to sequentially illuminate the sample. The resulting lensfree holograms are then captured by a digital sensor-array and are rapidly processed using a pixel super-resolution algorithm to generate much higher resolution holographic images (both phase and amplitude) of the objects. This wide-field and high-resolution on-chip microscope, being compact and light-weight, would be important for global health problems such as diagnosis of infectious diseases in remote locations. Toward this end, we validate the performance of this field-portable microscope by imaging human malaria parasites (Plasmodium falciparum) in thin blood smears. Our results constitute the first-time that a lensfree on-chip microscope has successfully imaged malaria parasites.
引用
收藏
页码:1276 / 1279
页数:4
相关论文
共 12 条
[1]   Holographic opto-fluidic microscopy [J].
Bishara, Waheb ;
Zhu, Hongying ;
Ozcan, Aydogan .
OPTICS EXPRESS, 2010, 18 (26) :27499-27510
[2]   Lensfree on-chip microscopy over a wide field-of-view using pixel super-resolution [J].
Bishara, Waheb ;
Su, Ting-Wei ;
Coskun, Ahmet F. ;
Ozcan, Aydogan .
OPTICS EXPRESS, 2010, 18 (11) :11181-11191
[3]   Mobile Phone Based Clinical Microscopy for Global Health Applications [J].
Breslauer, David N. ;
Maamari, Robi N. ;
Switz, Neil A. ;
Lam, Wilbur A. ;
Fletcher, Daniel A. .
PLOS ONE, 2009, 4 (07)
[4]   Ultrasonic particle-concentration for sheathless focusing of particles for analysis in a flow cytometer [J].
Goddard, G ;
Martin, JC ;
Graves, SW ;
Kaduchak, G .
CYTOMETRY PART A, 2006, 69A (02) :66-74
[5]   Joint MAP registration and high-resolution image estimation using a sequence of undersampled images [J].
Hardie, RC ;
Barnard, KJ ;
Armstrong, EE .
IEEE TRANSACTIONS ON IMAGE PROCESSING, 1997, 6 (12) :1621-1633
[6]   Portable, Battery-Operated, Low-Cost, Bright Field and Fluorescence Microscope [J].
Miller, Andrew R. ;
Davis, Gregory L. ;
Oden, Z. Maria ;
Razavi, Mohamad Reza ;
Fateh, Abolfazl ;
Ghazanfari, Morteza ;
Abdolrahimi, Farid ;
Poorazar, Shahin ;
Sakhaie, Fatemeh ;
Olsen, Randall J. ;
Bahrmand, Ahmad Reza ;
Pierce, Mark C. ;
Graviss, Edward A. ;
Richards-Kortum, Rebecca .
PLOS ONE, 2010, 5 (08)
[7]   Compact, light-weight and cost-effective microscope based on lensless incoherent holography for telemedicine applications [J].
Mudanyali, Onur ;
Tseng, Derek ;
Oh, Chulwoo ;
Isikman, Serhan O. ;
Sencan, Ikbal ;
Bishara, Waheb ;
Oztoprak, Cetin ;
Seo, Sungkyu ;
Khademhosseini, Bahar ;
Ozcan, Aydogan .
LAB ON A CHIP, 2010, 10 (11) :1417-1428
[8]  
OH C, 2010, C LAS EL OPT APPL OS
[9]   On-chip differential interference contrast microscopy using lensless digital holography [J].
Oh, Chulwoo ;
Isikman, Serhan O. ;
Khademhosseinieh, Bahar ;
Ozcan, Aydogan .
OPTICS EXPRESS, 2010, 18 (05) :4717-4726
[10]  
Park SC, 2003, IEEE SIGNAL PROC MAG, V20, P21, DOI 10.1109/MSP.2003.1203207