Effect of two different soft liners and thicknesses mediating stress transfer for immediately loaded 2-implant supported mandibular overdentures: A finite element analysis study

被引:13
|
作者
Radi, Iman Abd-Elwahab [1 ]
Elmahrouky, Nesrin [2 ]
机构
[1] Cairo Univ, Fac Oral & Dent Med, Prosthodont, Cairo, Egypt
[2] Al Azhar Univ, Fac Med Dent, Removable Prosthodont, Cairo, Egypt
关键词
LINING MATERIALS; COMPLETE DENTURE; IMPLANT; RESIN; BONE; STRENGTH;
D O I
10.1016/j.prosdent.2016.01.031
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. The use of soft liners as female receptacles for ball attachments retaining immediately loaded implant overdenture has been recommended to enhance osseointegration and provide a shock absorbing effect. However, which liner and which thickness is still unclear. Purpose. The purpose of this finite element analysis (FEA) study was to evaluate the effect of a 2 and 4-mm thickness of thermoplastic resin (TRL) and silicone-based liners (SBL) on the displacement and stresses transmitted to immediately loaded implants retaining a mandibular overdenture. Material and methods. Four 3-dimensional (3D) FEA models of a mandibular implant overdenture retained by 2 ball attachments (2 models for each lining material with 2- or 4-mm liner thicknesses) were developed. Implants were placed in the canine regions and surrounded by a 1-mm cylinder of immature bone simulating immediate loading. A vertical and an oblique load of 150 N were applied in the right premolar molar regions. Stresses and displacement were set as output variables. Results. Replacing the TRL by the SBL was associated with a decrease in stresses by 73% and in displacement by at least 46%. Increasing the thickness of any liner decreases stresses by 45% during vertical loading and by 25% during oblique loading and decreases displacement by 61.5% during vertical loading and by an average of 32.5% during oblique loading. None of the liners exceeded the experimental risk limits for micromotion at the bone-implant interface (50 mu m). Conclusion. In immediately loaded mandibular implant overdentures, both SBL and TRL decrease the micromotion of implants and the stresses at the bond-implant interface. However, SBL is more effective. The thickness of both liners seems to play a major role in decreasing the stresses and displacement of periimplant tissues.
引用
收藏
页码:356 / 361
页数:6
相关论文
共 16 条
  • [1] RESEARCH AND EDUCATION Different implant diameters and their effect on stress distribution pattern in 2-implant mandibular overdentures: A 3D finite element analysis study
    Patil, Pravinkumar G.
    Seow, Liang Lin
    Uddanwadikar, Rashmi
    Pau, Allan
    Ukey, Piyush D.
    JOURNAL OF PROSTHETIC DENTISTRY, 2024, 131 (04) : 675 - 682
  • [2] The effect of implant number and position on the stress behavior of mandibular implant retained overdentures: A three-dimensional finite element analysis
    Topkaya, Tolga
    Solmaz, Murat Yavuz
    JOURNAL OF BIOMECHANICS, 2015, 48 (10) : 2102 - 2109
  • [3] Evaluation of Stress Distribution on Mandibular Implant-Supported Overdentures With Different Bone Heights and Attachment Types: A 3D Finite Element Analysis
    Unsal, Gokce Soganci
    Erbasar, Guzin Neda Hasanoglu
    Aykent, Filiz
    Ozyilmaz, Ozgun Yusuf
    Ozdogan, Mahmut Sertac
    JOURNAL OF ORAL IMPLANTOLOGY, 2019, 45 (05) : 363 - 370
  • [4] Effect of Different Framework Materials in Implant-Supported Fixed Mandibular Prostheses: A Finite Element Analysis
    Sirandoni, Diego
    Leal, Eduardo
    Weber, Benjamin
    Noritomi, Pedro Yoshito
    Fuentes, Ramon
    Borie, Eduardo
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2019, 34 (06) : E107 - E114
  • [5] Influence of different polymeric materials of implant and attachment on stress distribution in implant-supported overdentures: a three-dimensional finite element study
    Elsayed, Sherif
    Ahmed, Yousra
    El-Anwar, Mohamed I.
    Elddamony, Enas
    Ashraf, Reem
    BMC ORAL HEALTH, 2025, 25 (01):
  • [6] Influence of Implant Positions and Occlusal Forces on Peri-Implant Bone Stress in Mandibular Two-Implant Overdentures: A 3-Dimensional Finite Element Analysis
    Alvarez-Arenal, Angel
    Gonzalez-Gonzalez, Ignacio
    deLlanos-Lanchares, Hector
    Brizuela-Velasco, Aritza
    Martin-Fernandez, Elena
    Ellacuria-Echebarria, Joseba
    JOURNAL OF ORAL IMPLANTOLOGY, 2017, 43 (06) : 419 - 428
  • [7] Implant-Retained Mandibular Bar-Supported Overlay Dentures: A Finite Element Stress Analysis of Four Different Bar Heights
    Rismanchian, Mansoor
    Dakhilian, Mansour
    Bajoghli, Farshad
    Ghasemi, Ehsan
    Sadr-Eshkevari, Pooyan
    JOURNAL OF ORAL IMPLANTOLOGY, 2012, 38 (02) : 133 - 139
  • [8] The effect of different abutment and restorative crown materials on stress distribution in single-unit implant-supported restorations: A 3D finite element stress analysis
    Gokcimen, Gulsum
    Durkan, Rukiye
    Gokay, Gonca
    Oyar, Perihan
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2024, 33 (05): : 497 - 505
  • [9] The Effect of Implant Length and Diameter on Stress Distribution of Tooth-Implant and Implant Supported Fixed Prostheses: An In Vitro Finite Element Analysis Study
    Naguib, Ghada H.
    Hashem, Abou Bakr H.
    Natto, Zuhair S.
    Abougazia, Ahmed O.
    Mously, Hisham A.
    Hamed, Mohamed T.
    JOURNAL OF ORAL IMPLANTOLOGY, 2023, 49 (01) : 46 - 54
  • [10] Evaluation of Stress Distribution of Mini Dental Implant-Supported Overdentures in Complete Cleft Palate Models: A Three-Dimensional Finite Element Analysis Study
    Soganci, Gokce
    Yazicioglu, Huseyin
    CLEFT PALATE-CRANIOFACIAL JOURNAL, 2016, 53 (01) : 73 - 83