Optical pH sensing using spectral analysis

被引:16
作者
Fritzsche, M. [1 ]
Barreiro, C. G. [1 ]
Hitzmann, B. [1 ]
Scheper, T. [1 ]
机构
[1] Leibniz Univ Hannover, Inst Tech Chem, D-30167 Hannover, Germany
关键词
pH sensing; chemometrics; ratiometric sensors; fluorescence; aminofluorescein; temperature dependence;
D O I
10.1016/j.snb.2007.05.041
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Spectral analysis by chemometric methods is applied to optical pH sensing with aminofluorescein as fluorescent indicator. This method is superior to the ratiometric dual-wavelength detection when the pH value influences the spectrum in a complex way. In the case of aminofluorescein the range of measurement is extended compared to the ratiometric method. The pH value can be calculated from the fluorescence spectra of the indicator independently of the absolute intensity and of the temperature of the sample. At high indicator concentrations the fluorescence spectra are strongly influenced by inner filter effects and the error of the pH prediction is significantly smaller than in a dilute solution. The reduction of the fluorescence spectra to a few data points shows that the chemometric pH determination does not require high-resolution spectral sensors. (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:133 / 137
页数:5
相关论文
共 9 条
[1]   Low-cost noninvasive optical CO2 sensing system for fermentation and cell culture [J].
Ge, XD ;
Kostov, Y ;
Rao, G .
BIOTECHNOLOGY AND BIOENGINEERING, 2005, 89 (03) :329-334
[2]   Some recent advances in fluorescence spectroscopy [J].
Miller, JN .
ANALYTICAL LETTERS, 2006, 39 (05) :851-862
[3]   FIBEROPTIC SENSORS FOR PH AND CARBON-DIOXIDE USING A SELF-REFERENCING DYE [J].
PARKER, JW ;
LAKSIN, O ;
YU, C ;
LAU, ML ;
KLIMA, S ;
FISHER, R ;
SCOTT, I ;
ATWATER, BW .
ANALYTICAL CHEMISTRY, 1993, 65 (17) :2329-2334
[4]  
Szmacinski H, 1994, TOPICS FLUORESCENCE, V4, P295
[5]   Noninvasive measurement of dissolved oxygen in shake flasks [J].
Tolosa, L ;
Kostov, Y ;
Harms, P ;
Rao, G .
BIOTECHNOLOGY AND BIOENGINEERING, 2002, 80 (05) :594-597
[6]   Fluorescent pH sensors with negligible sensitivity to ionic strength [J].
Weidgans, BM ;
Krause, C ;
Klimant, I ;
Wolfbeis, OS .
ANALYST, 2004, 129 (07) :645-650
[7]   Materials for fluorescence-based optical chemical sensors [J].
Wolfbeis, OS .
JOURNAL OF MATERIALS CHEMISTRY, 2005, 15 (27-28) :2657-2669
[8]  
Wolfbeis OS, 2004, ANAL CHEM, V76, P3269, DOI [10.1021/ac040049d, 10.1021/a1000013k]
[9]   POLYVINYL-ALCOHOL) AS A SUBSTRATE FOR INDICATOR IMMOBILIZATION FOR FIBER-OPTIC CHEMICAL SENSORS [J].
ZHUJUN, Z ;
ZHANG, Y ;
WANGBAI, M ;
RUSSELL, R ;
SHAKHSHER, ZM ;
GRANT, CL ;
SEITZ, WR ;
SUNDBERG, DC .
ANALYTICAL CHEMISTRY, 1989, 61 (03) :202-205