Baby-Guard: An IoT-based Neonatal Monitoring System Integrated with Smart Textiles

被引:8
作者
Cay, Gozde [1 ]
Solanki, Dhaval [1 ]
Ravichandran, Vignesh [1 ]
Hoffman, Laurie [2 ]
Laptook, Abbot [2 ]
Padbury, James [2 ]
Salisbury, Amy L. [2 ,3 ]
Mankodiya, Kunal [1 ]
机构
[1] Univ Rhode Isl, Dept Elect Comp & Biomed Engn, Kingston, RI 02881 USA
[2] Women & Infants Hosp Rhode Isl, Pediat, Providence, RI USA
[3] Virginia Commonwealth Univ, Sch Nursing, Richmond, VA USA
来源
2021 IEEE INTERNATIONAL CONFERENCE ON SMART COMPUTING (SMARTCOMP 2021) | 2021年
关键词
Internet of Things; IoT; NICU; Neonatal Care; Health Monitoring; Respiration Monitoring; Smart Textiles; MEDICAL ADHESIVES; SAFETY;
D O I
10.1109/SMARTCOMP52413.2021.00038
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
A rising number of preterm babies demands innovative solutions to monitor them in the Neonatal Intensive Care Unit (NICU) continuously. NICU monitors various kinds of vital signs. Among them, there is a strong demand for an accurate and sophisticated technology to monitor respiration rate (RR) and detect critical events such as apnea. Existing solutions for RR monitoring either rely on the indirect measurements from thoracic impedance or other invasive techniques posing discomfort and risk of infections to babies. Also, multiple wire loops lying around babies hinder the delivery of parental and clinical care. Motivated by this need, we have designed an Internet-of-Things (IoT) based smart textile chest belt called "Baby-Guard" to monitor RR and detect apnea. The Baby-Guard is a neonatal wearable system consisting of a sensor belt, a wearable embedded system, and an edge computing device. The sensor belt consists of textile-based pressure sensors and an Inertial Measurement Unit (IMU). The wearable system consists of a microcontroller equipped with wireless connectivity and power management. The edge computing device (ECD) connects with the wearable system through an MQTT networking architecture. ECD hosts signal processing and computing services to extract RR and detect apnea. We conducted simulation experiments using a high-fidelity, programmable NICU baby mannequin. We found an average error of 0.89 BrPM in breathing rate and similar to 97 percent accuracy in apnea detection. Computation and communication latencies were found to be similar to 66 and 22 ms, respectively. The Baby-Guard showed potential to be a wireless infant monitoring system in the NICU settings.
引用
收藏
页码:129 / 136
页数:8
相关论文
共 27 条
[1]  
Ahouandjinou ASRM, 2016, 2016 INTERNATIONAL CONFERENCE ON BIO-ENGINEERING FOR SMART TECHNOLOGIES (BIOSMART)
[2]  
[Anonymous], 2017, MESSAGE Q TELEMETRY
[3]  
August D.L., 2017, Journal of Neonatal Nursing, V24, P173, DOI [10.1016/j.jnn.2017.08.003, DOI 10.1016/J.JNN.2017.08.003]
[4]  
Bastwadkar Meghana, 2020, ICMHI 2020: Proceedings of the 4th International Conference on Medical and Health Informatics, P30, DOI 10.1145/3418094.3418130
[5]  
eclipse, PAHO MQTT
[6]  
Fahmi F., 2020, IOP C SERIES MAT SCI, V1003
[7]   Design of A Wearable Fiber Optic Respiration Sensor for Application in NICU Incubators [J].
Hariyanti ;
Devara, Kresna ;
Aisyah, Fitriyanti Nur ;
Nadia, Ketut Vanda Aryanthera Wisnu ;
Purnamaningsih, Retno Wigajatri .
3RD BIOMEDICAL ENGINEERING'S RECENT PROGRESS IN BIOMATERIALS, DRUGS DEVELOPMENT, AND MEDICAL DEVICES, 2019, 2092
[8]   IoT-BBMS: Internet of Things-Based Baby Monitoring System for Smart Cradle [J].
Jabbar, Waheb A. ;
Shang, Hiew Kuet ;
Hamid, Saidatul N. I. S. ;
Almohammedi, Akram A. ;
Ramli, Roshahliza M. ;
Ali, Mohammed A. H. .
IEEE ACCESS, 2019, 7 :93791-93805
[9]   Alarm Safety and Alarm Fatigue [J].
Johnson, Kendall R. ;
Hagadorn, James I. ;
Sink, David W. .
CLINICS IN PERINATOLOGY, 2017, 44 (03) :713-+
[10]   Assessment of Signal Processing Methods for Measuring the Respiratory Rate in the Neonatal Intensive Care Unit [J].
Jorge, Joao ;
Villarroel, Mauricio ;
Chaichulee, Sitthichok ;
Green, Gabrielle ;
McCormick, Kenny ;
Tarassenko, Lionel .
IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2019, 23 (06) :2335-2346