Improving the reproducibility, accuracy, and stability of an electrochemical biosensor platform for point-of-care use

被引:92
作者
Chen, Lung-Chieh [1 ,2 ]
Wang, Erick [1 ]
Tai, Chun-San [1 ,2 ]
Chiu, Yuan-Chen [1 ,2 ]
Li, Chang-Wei [1 ,3 ]
Lin, Yan-Ren [4 ,5 ,6 ]
Lee, Tsung-Han [1 ,4 ]
Huang, Ching-Wen [1 ,8 ,9 ]
Chen, Jung-Chih [1 ,7 ]
Chen, Wen Liang [1 ]
机构
[1] Natl Chiao Tung Univ, Dept Biol Sci & Technol, Hsinchu 30010, Taiwan
[2] Natl Chiao Tung Univ, Inst Mol Med & Bioengn, Hsinchu, Taiwan
[3] AllBio Life Inc, Taichung, Taiwan
[4] Changhua Christian Hosp, Dept Emergency Med, Changhua, Taiwan
[5] Kaohsiung Med Univ, Sch Med, Kaohsiung, Taiwan
[6] Chung Shan Med Univ, Sch Med, Taichung, Taiwan
[7] Natl Chiao Tung Univ, Inst Biomed Engn, Hsinchu 30010, Taiwan
[8] Taipei Med Univ, Shuang Ho Hosp, Dept Emergency, New Taipei, Taiwan
[9] Taipei Med Univ, Coll Med, Sch Med, Dept Surg,Div Thorac Surg, Taipei, Taiwan
关键词
Semiconductor manufacturing technology; Biotin-streptavidin system; Label-free electrochemical platform; Point-of-care testing (POCT); LABEL-FREE; PROTEIN; TECHNOLOGY; ELECTRODE; SAMS;
D O I
10.1016/j.bios.2020.112111
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Electrochemical biosensors possess numerous desirable qualities for target detection, such as portability and ease of use, and are often considered for point-of-care (POC) development. Label-free affinity electrochemical biosensors constructed with semiconductor manufacturing technology (SMT)-produced electrodes and a streptavidin biomediator currently display the highest reproducibility, accuracy, and stability in modern biosensors. However, such biosensors still do not meet POC guidelines regarding these three characteristics. The purpose of this research was to resolve the limitations in reproducibility and accuracy caused by problems with production of the biosensors, with the aim of developing a platform capable of producing devices that exceed POC standards. SMT production settings were optimized and bioreceptor immobilization was improved through the use of a unique linker, producing a biosensor with exceptional reproducibility, impressive accuracy, and high stability. Importantly, the three characteristics of the sensors produced using the proposed platform all meet POC standards set by the Clinical and Laboratory Standards Institute (CLSI). This suggests possible approval of the biosensors for POC development. Furthermore, the detection range of the platform was demonstrated by constructing biosensors capable of detecting common POC targets, including circulating tumor cells (CTCs), DNA/RNA, and curcumin, and the devices were optimized for POC use. Overall, the platform developed in this study shows high potential for production of POC biosensors.
引用
收藏
页数:8
相关论文
共 32 条
  • [21] An Organic Field-effect Transistor with an Extended-gate Electrode Capable of Detecting Human Immunoglobulin A
    Minamiki, Tsukuru
    Minami, Tsuyoshi
    Sasaki, Yui
    Kurita, Ryoji
    Niwa, Osamu
    Wakida, Shin-ichi
    Tokito, Shizuo
    [J]. ANALYTICAL SCIENCES, 2015, 31 (07) : 725 - 728
  • [22] Carbodiimide/NHS Derivatization of COOH-Terminated SAMs: Activation or Byproduct Formation?
    Palazon, Francisco
    Benavides, Cindy Montenegro
    Leonard, Didier
    Souteyrand, Eliane
    Chevolot, Yann
    Cloarec, Jean-Pierre
    [J]. LANGMUIR, 2014, 30 (16) : 4545 - 4550
  • [23] Biosensors Based on Semiconductors, a Review
    Pohanka, Miroslav
    Leuchter, Jan
    [J]. INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2017, 12 (07): : 6611 - 6621
  • [24] Seesawed fluorescence nano-aptasensor based on highly vertical ZnO nanorods and three-dimensional quantitative fluorescence imaging for enhanced detection accuracy of ATP
    Shrivastava, Sajal
    Nguyen Minh Triet
    Son, Young-Min
    Lee, Won-Il
    Lee, Nae-Eung
    [J]. BIOSENSORS & BIOELECTRONICS, 2017, 90 : 450 - 458
  • [25] Innovation in biotechnology: moving from academic research to product development-the case of biosensors
    Siontorou, Christina G.
    Batzias, Fragiskos A.
    [J]. CRITICAL REVIEWS IN BIOTECHNOLOGY, 2010, 30 (02) : 79 - 98
  • [26] Interaction of αS1-Casein with Curcumin and Its Biological Implications
    Sneharani, Athahalli H.
    Singh, Sridevi Annapurna
    Rao, A. G. Appu
    [J]. JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2009, 57 (21) : 10386 - 10391
  • [27] A Study on the Formation and Thermal Stability of 11-MUA SAMs on Au(111)/Mica and on Polycrystalline Gold Foils
    Stettner, Johanna
    Frank, Paul
    Griesser, Thomas
    Trimmel, Gregor
    Schennach, Robert
    Gilli, Eduard
    Winkler, Adolf
    [J]. LANGMUIR, 2009, 25 (03) : 1427 - 1433
  • [28] Electrochemical cardiovascular platforms: Current state of the art and beyond
    Szunerits, Sabine
    Mishyn, Vladyslav
    Grabowska, Iwona
    Boukherroub, Rabah
    [J]. BIOSENSORS & BIOELECTRONICS, 2019, 131 : 287 - 298
  • [29] Antibody orientation on biosensor surfaces: a minireview
    Trilling, Anke K.
    Beekwilder, Jules
    Zuilhof, Han
    [J]. ANALYST, 2013, 138 (06) : 1619 - 1627
  • [30] In situ study of EDC/NHS immobilization on gold surface based on attenuated total reflection surface-enhanced infrared absorption spectroscopy (ATR-SEIRAS)
    Tsai, Tien-Chun
    Liu, Chia-Wei
    Wu, Yi-Chen
    Ondevilla, Neil Adrian P.
    Osawa, Masatoshi
    Chang, Hsien-Chang
    [J]. COLLOIDS AND SURFACES B-BIOINTERFACES, 2019, 175 : 300 - 305