Comparison of optical low-coherence reflectometry and applanation ultrasound biometry on intraocular lens power calculation

被引:32
作者
Roncevic, Mirjana Bjelos [1 ]
Busic, Mladen [1 ]
Cima, Ivan [1 ]
Elabjer, Biljana Kuzmanovic [1 ]
Bosnar, Damir [1 ]
Miletic, Daliborka [1 ]
机构
[1] Univ Hosp Sveti Duh, Univ Eye Clin, Zagreb 10000, Croatia
关键词
Biometry; Cataract; Optical low-coherence reflectometry; Applanation ultrasound; Intraocular lens; ANTERIOR-CHAMBER DEPTH; CATARACT-SURGERY; AXIAL LENGTH; IMMERSION ULTRASOUND; OCULAR BIOMETRY; INTERFEROMETRY; ACCURACY; REPRODUCIBILITY; IOLMASTER; CONTACT;
D O I
10.1007/s00417-010-1509-4
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
The aim of the study was to determine whether the innovative non-contact optical low-coherence reflectometry method utilized by the Lenstar LS 900A (R) agrees sufficiently with applanation ultrasound A-scan technique in routine biometric measurement and intraocular lens power calculation to replace it. Twenty-two patients hospitalized at our eye clinic undergoing cataract surgery were assigned to have five consecutive measurements of axial length by two examiners in a single session using applanation ultrasound and the Lenstar. The applanation ultrasound intraocular lens power calculation was based on automated keratometry and applanation ultrasound axial length measurements. The Lenstar intraocular lens power calculation was based on its measurement of keratometry and axial length. Bland-Altman analysis was used to assess interobserver repeatability of applanation ultrasound and the Lenstar as well as agreement between the Lenstar and applanation ultrasound for axial length measurement and intraocular lens power calculation. Thirty-two eyes of 22 patients were analyzed. In 95% of the observations, predicted refractive error corresponded to -0.26 +/- 0.62 D and 0.01 +/- 0.20 D obtained with applanation ultrasound and the Lenstar, respectively. Based on excellent repeatability of the Lenstar and acceptable repeatability of applanation ultrasound, two techniques may be used interchangeably. The predicted refractive error of +/- 0.20 D in 95% of the observations has never been achieved. Optical low-coherence reflectometry might become a new standard method for biometric measurement needed for intraocular lens-power calculation in patients with cataract.
引用
收藏
页码:69 / 75
页数:7
相关论文
共 50 条
  • [41] The comparison of the intraocular lens power calculation formulas in long eyes
    Yildiz, Aydin
    JOURNAL OF THE PAKISTAN MEDICAL ASSOCIATION, 2020, 70 (07) : 1173 - 1176
  • [42] Accuracy of optical biometry combined with Placido disc corneal topography for intraocular lens power calculation
    Savini, Giacomo
    Hoffer, Kenneth J.
    Barboni, Piero
    Balducci, Nicole
    Schiano-Lomoriello, Domenico
    Ducoli, Pietro
    PLOS ONE, 2017, 12 (02):
  • [43] Predictive value of intracrystalline interphase point measured by optical low-coherence reflectometry for the estimation of the anatomical position of an intraocular lens after cataract surgery
    Javier Castro-Alonso, Francisco
    Bordonaba-Bosque, Daniel
    Pinero, David P.
    Latre-Rebled, Beatriz
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2019, 45 (09) : 1294 - 1304
  • [44] Intraocular lens Master optical biometry vs conventional ultrasonic biometry in intraocular lens power calculations in highly myopic vs emmetropic eyes
    Gad, Mina N.
    Mourad, Mervat S.
    Rehan, Rafaat A.
    Mustafa, Mouamen M.
    JOURNAL OF THE EGYPTIAN OPHTHALMOLOGICAL SOCIETY, 2020, 113 (02) : 39 - 45
  • [45] Evaluation of Refractive Predictive Accuracy in Intraocular Lens Power Calculations: A Comparative Study of Swept-Source Optical Coherence Tomography and Optical Low-Coherence Interferometry
    Al Barri, Leila
    Mercea, Nadina
    Ionela-Iasmina, Yasar
    Munteanu, Mihnea
    Stanca, Horia T.
    JOURNAL OF CLINICAL MEDICINE, 2025, 14 (04)
  • [46] Comparison of Central Corneal Thickness Measurements With Optical Low-Coherence Reflectometry and Ultrasound Pachymetry and Reproducibility of Both Devices
    Koktekir, Bengu E.
    Gedik, Sansal
    Bakbak, Berker
    CORNEA, 2012, 31 (11) : 1278 - 1281
  • [47] Partial coherence laser interferometry vs conventional ultrasound biometry in intraocular lens power calculations
    M S Rajan
    I Keilhorn
    J A Bell
    Eye, 2002, 16 : 552 - 556
  • [48] Partial coherence laser interferometry vs conventional ultrasound biometry in intraocular lens power calculations
    Rajan, MS
    Keilhorn, I
    Bell, JA
    EYE, 2002, 16 (05) : 552 - 556
  • [49] Comparison and Evaluation of Ocular Biometry Using a New Noncontact Optical Low-Coherence Reflectometer
    Rohrer, Kaspar
    Frueh, Beatrice E.
    Waelti, Rudolf
    Clemetson, Isabelle A.
    Tappeiner, Christoph
    Goldblum, David
    OPHTHALMOLOGY, 2009, 116 (11) : 2087 - 2092
  • [50] Comparison of Anterior Segment Measurements with Optical Low-coherence Reflectometry and Partial-coherence Interferometry Optical Biometers
    Can, Ertugrul
    Duran, Mustafa
    Cetinkaya, Tugba
    Ariturk, Nursen
    MIDDLE EAST AFRICAN JOURNAL OF OPHTHALMOLOGY, 2016, 23 (04) : 288 - 292