Comparison of optical low-coherence reflectometry and applanation ultrasound biometry on intraocular lens power calculation

被引:32
作者
Roncevic, Mirjana Bjelos [1 ]
Busic, Mladen [1 ]
Cima, Ivan [1 ]
Elabjer, Biljana Kuzmanovic [1 ]
Bosnar, Damir [1 ]
Miletic, Daliborka [1 ]
机构
[1] Univ Hosp Sveti Duh, Univ Eye Clin, Zagreb 10000, Croatia
关键词
Biometry; Cataract; Optical low-coherence reflectometry; Applanation ultrasound; Intraocular lens; ANTERIOR-CHAMBER DEPTH; CATARACT-SURGERY; AXIAL LENGTH; IMMERSION ULTRASOUND; OCULAR BIOMETRY; INTERFEROMETRY; ACCURACY; REPRODUCIBILITY; IOLMASTER; CONTACT;
D O I
10.1007/s00417-010-1509-4
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
The aim of the study was to determine whether the innovative non-contact optical low-coherence reflectometry method utilized by the Lenstar LS 900A (R) agrees sufficiently with applanation ultrasound A-scan technique in routine biometric measurement and intraocular lens power calculation to replace it. Twenty-two patients hospitalized at our eye clinic undergoing cataract surgery were assigned to have five consecutive measurements of axial length by two examiners in a single session using applanation ultrasound and the Lenstar. The applanation ultrasound intraocular lens power calculation was based on automated keratometry and applanation ultrasound axial length measurements. The Lenstar intraocular lens power calculation was based on its measurement of keratometry and axial length. Bland-Altman analysis was used to assess interobserver repeatability of applanation ultrasound and the Lenstar as well as agreement between the Lenstar and applanation ultrasound for axial length measurement and intraocular lens power calculation. Thirty-two eyes of 22 patients were analyzed. In 95% of the observations, predicted refractive error corresponded to -0.26 +/- 0.62 D and 0.01 +/- 0.20 D obtained with applanation ultrasound and the Lenstar, respectively. Based on excellent repeatability of the Lenstar and acceptable repeatability of applanation ultrasound, two techniques may be used interchangeably. The predicted refractive error of +/- 0.20 D in 95% of the observations has never been achieved. Optical low-coherence reflectometry might become a new standard method for biometric measurement needed for intraocular lens-power calculation in patients with cataract.
引用
收藏
页码:69 / 75
页数:7
相关论文
共 50 条
  • [31] Biometry and intraocular lens power calculation for cataract surgery: an update
    Findl, O.
    SPEKTRUM DER AUGENHEILKUNDE, 2007, 21 (02) : 90 - 93
  • [32] Validation of Optical Low Coherence Reflectometry Retinal and Choroidal Biometry
    Read, Scott A.
    Collins, Michael J.
    Alonso-Caneiro, David
    OPTOMETRY AND VISION SCIENCE, 2011, 88 (07) : 855 - 863
  • [33] Comparison of two biometers: A swept-source optical coherence tomography and an optical low-coherence reflectometry biometer
    El Chehab, Hussam
    Agard, Emilie
    Dot, Corinne
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2019, 29 (05) : 547 - 554
  • [34] CLINICAL VARIABILITY IN KERATOMETRY, ULTRASOUND BIOMETRY MEASUREMENTS, AND EMMETROPIC INTRAOCULAR-LENS POWER CALCULATION
    PIERRO, L
    MODORATI, G
    BRANCATO, R
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1991, 17 (01) : 91 - 94
  • [35] Comparison of optical low-coherence reflectometry and ultrasound pachymetry in measuring corneal graft thickness
    Gaujoux, Thomas
    Borderie, Vincent M.
    Yousfi, Hakim
    Bourcier, Tristan
    Touzeau, Olivier
    Laroche, Laurent
    CORNEA, 2007, 26 (02) : 185 - 189
  • [36] Evaluation and comparison of a novel Scheimpflug-based optical biometer with standard partial coherence interferometry for biometry and intraocular lens power calculation
    Wang, Ziyang
    Yang, Wenli
    Li, Dongjun
    Chen, Wei
    Zhao, Qi
    Li, Yifeng
    Cui, Rui
    Shen, Lin
    Xian, Junfang
    EXPERIMENTAL AND THERAPEUTIC MEDICINE, 2021, 21 (04)
  • [37] Comparison of Ocular Biometric Measurements Using New Swept-source Optical-coherence Tomography, Low-coherence Reflectometry, A-Scan Biometry, and Autokeratometry
    Cho, Jae Jin
    Bae, Gi Hyun
    JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, 2023, 64 (04): : 287 - 295
  • [38] The comparison of the intraocular lens power calculation formulas in long eyes
    Yildiz, Aydin
    JOURNAL OF THE PAKISTAN MEDICAL ASSOCIATION, 2020, 70 (07) : 1173 - 1176
  • [39] Biometry with a new swept-source optical coherence tomography biometer: Repeatability and agreement with an optical low-coherence reflectometry device
    Kurian, Mathew
    Negalur, Nikhil
    Das, Sudeep
    Puttaiah, Narendra K.
    Haria, Dhawal
    Tejal, S. J.
    Thakkar, Maithil M.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2016, 42 (04) : 577 - 581
  • [40] Comparision of Optical Low Coherence Reflectometry Versus Ultrasonic Biometry in High Hypermetropia
    Aydin, Rukiye
    Erdur, Sevil Karaman
    Cabuk, Kubra Serefoglu
    Karahan, Eyyup
    Kaynak, Suleyman
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2018, 44 : S115 - S117