Assessment of the primary stability of root analog zirconia implants designed using cone beam computed tomography software by means of the Periotest® device: An ex vivo study. A preliminary report

被引:22
作者
Matys, Jacek [1 ]
Swider, Katarzyna [1 ]
Flieger, Rafal [1 ]
Dominiak, Marzena [1 ]
机构
[1] Wroclaw Med Univ, Dent Surg Dept, Wroclaw, Poland
来源
ADVANCES IN CLINICAL AND EXPERIMENTAL MEDICINE | 2017年 / 26卷 / 05期
关键词
RAZI; primary stability; root analog zirconia implant; Periotest; RESONANCE FREQUENCY-ANALYSIS; DENTAL IMPLANTS; CLINICAL-TRIAL; FOLLOW-UP; IMMEDIATE; BONE; TECHNOLOGY; PLACEMENT; ACCURACY; TORQUE;
D O I
10.17219/acem/65069
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Background. The implant primary stability is a fundamental prerequisite for a success of osseointegration process which determines the prosthetic reconstruction time. Objectives. The aim of the present study was to assess the quality and precision of modern conical bone computer tomography (CBCT) software in preparing root analog zirconia implants (RAZIs) by measuring its primary stability by means of the Periotest device. Material and methods. Thirteen pig jaws with proper erupted first premolar (P1) teeth were used in the study. The CBCT examination was conducted in the area of the P1 tooth in each mandible. The 3-dimensional (3D) view of each tooth was designed from CBCT scan. The created 3D images were used to prepare root analog zirconia implants milled from a medical-grade zirconia block by means of laboratory milling. The RAZIs and titanium implants were placed into an alveolar socket after the tooth had been removed. The primary stability of the teeth before their extraction (G1), RAZIs (G2) and titanium implants (G3) were checked by Periotest devices. Results. The mean results in PTV were: 15.9, 3.35, 12.7 for G1, G2 and G3 group, respectively. RAZIs during immediate loading achieved a significantly higher primary stability (lower Periotest value) as compared to the teeth and implants. Conclusions. The modern CBCT device allows us to design a precise image of an extracted tooth for the purpose of manufacturing a root analog implant. The additional feature of the surgical protocol using RAZI is the possibility of avoiding the augmentation procedure, which reduces the whole cost of the treatment.
引用
收藏
页码:803 / 809
页数:7
相关论文
共 30 条
[1]   Accuracy assessment of three-dimensional surface reconstructions of teeth from Cone Beam Computed Tomography scans [J].
Al-Rawi, B. ;
Hassan, B. ;
Vandenberge, B. ;
Jacobs, R. .
JOURNAL OF ORAL REHABILITATION, 2010, 37 (05) :352-358
[2]  
Atsumi M, 2007, INT J ORAL MAX IMPL, V22, P743
[3]  
Binahmed A, 2007, INT J ORAL MAX IMPL, V22, P963
[4]  
Brunski JB, 2000, INT J ORAL MAX IMPL, V15, P15
[5]  
Chahine G, 2011, IMPLANT DENTISTRY RA, P251
[6]   DESIGN AND MANUFACTURE OF CUSTOMIZED DENTAL IMPLANTS BY USING REVERSE ENGINEERING AND SELECTIVE LASER MELTING TECHNOLOGY [J].
Chen, Jianyu ;
Zhang, Zhiguang ;
Chen, Xianshuai ;
Zhang, Chunyu ;
Zhang, Gong ;
Xu, Zhewu .
JOURNAL OF PROSTHETIC DENTISTRY, 2014, 112 (05) :1088-+
[7]   Osseointegration of zirconia implants compared with titanium: An in vivo study [J].
Depprich R. ;
Zipprich H. ;
Ommerborn M. ;
Naujoks C. ;
Wiesmann H.-P. ;
Kiattavorncharoen S. ;
Lauer H.-C. ;
Meyer U. ;
Kübler N.R. ;
Handschel J. .
Head & Face Medicine, 4 (1)
[8]   Required minimum primary stability and torque values for immediate loading of mini dental implants: an experimental study in nonviable bovine femoral bone [J].
Dilek, Ozkan ;
Tezulas, Emre ;
Dincel, Mert .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2008, 105 (02) :E20-E27
[9]   Resonance frequency analysis of one-stage dental implant stability during the osseointegration period [J].
Ersanli, S ;
Karabuda, C ;
Beck, F ;
Leblebicioglu, B .
JOURNAL OF PERIODONTOLOGY, 2005, 76 (07) :1066-1071
[10]  
Friberg B, 1999, INT J ORAL MAX SURG, V28, P297