Standardization of Sonographic Diaphragm Thickness Evaluations in Healthy Volunteers

被引:80
作者
Carrillo-Esper, Raul [1 ]
Augusto Perez-Calatayud, Angel [2 ]
Arch-Tirado, Emilio [3 ]
Alejandro Diaz-Carrillo, Manuel [2 ]
Garrido-Aguirre, Eduardo [2 ]
Tapia-Velazco, Rafael [2 ]
Alberto Pena-Perez, Carlos [2 ]
Espinoza-de los Monteros, Isis [2 ]
Martin Meza-Marquez, Jose [2 ]
Ivan Flores-Rivera, Oscar [2 ]
Denise Zepeda-Mendoza, Adriana [2 ]
de la Torre-Leon, Teresa [2 ]
机构
[1] Fdn Clin Med Sur, Dept Crit Care, Mexico City 14050, DF, Mexico
[2] Fdn Clin Med Sur, Dept Crit Care Med, Mexico City 14050, DF, Mexico
[3] Natl Inst Rehabil, Res Med Sci Neurorehabil Lab, Mexico City, DF, Mexico
关键词
diaphragm thickness; ultrasound; PHRENIC-NERVE CONDUCTION; MECHANICAL VENTILATION; CONTRACTILE PROPERTIES; ULTRASOUND; ULTRASONOGRAPHY; REPRODUCIBILITY; VALUES; MOTION;
D O I
10.4187/respcare.03999
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
BACKGROUND: B-mode ultrasound can be used to measure diaphragm thickness at the zone of apposition. We believe it is necessary to develop normal values for diaphragm thickness at rest in a large group of healthy subjects and compare them with international results. METHODS: Ultrasound measurements of diaphragm thickness at expiratory rest were taken in 109 healthy individuals, with results stratified by sex, body mass index, and thorax circumference. The following methods were used for analysis and interpretation. Multivariable databases with descriptive statistical analyses were made. The Pearson chi-square test was used to evaluate the distribution between variables. Additionally, mean and SD values were calculated. For standardization, the data were separated by sex within a 95% CI, and we calculated a Z test. A 95% CI was also constructed for proportion analyses. RESULTS: One hundred nine healthy volunteers were included in the study, and the correlation between the body mass index and thorax circumference values with a Pearson chi-square test resulted in an r = 0.69. Additionally, the average value of diaphragmatic thickness was 0.19 +/- 0.04 cm (95% CI 0.17-0.20 cm) for men and 0.14 +/- 0.03 cm (95% CI 0.13-0.15 cm) for women (P = .001). There was no relation between body mass index thorax circumference, and diaphragmatic thickness. CONCLUSION: Real-time ultrasound of the diaphragm is a simple, inexpensive, and portable imaging technique that can provide qualitative anatomical information. The findings in this study show that sonographic diaphragm evaluations can be applied to the general population.
引用
收藏
页码:920 / 924
页数:5
相关论文
共 17 条
[1]   Non-invasive quantification of diaphragm kinetics using m-mode sonography [J].
Ayoub, J ;
Cohendy, R ;
Dauzat, M ;
Targhetta, R ;
DeLaCoussaye, JE ;
Bourgeois, JM ;
Ramonatxo, M ;
Prefaut, C ;
Pourcelot, L .
CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 1997, 44 (07) :739-744
[2]   NEEDLE ELECTROMYOGRAPHY OF THE DIAPHRAGM [J].
BOLTON, CF ;
GRANDMAISON, F ;
PARKES, A ;
SHKRUM, M .
MUSCLE & NERVE, 1992, 15 (06) :678-681
[3]   Two-dimensional ultrasound imaging of the diaphragm: Quantitative values in normal subjects [J].
Boon, Andrea J. ;
Harper, Caitlin J. ;
Ghahfarokhi, Leili Shahgholi ;
Strommen, Jeffrey A. ;
Watson, James C. ;
Sorenson, Eric J. .
MUSCLE & NERVE, 2013, 47 (06) :884-889
[4]   Diaphragmatic Motion Studied by M-Mode Ultrasonography Methods, Reproducibility, and Normal Values [J].
Boussuges, Alain ;
Gole, Yoann ;
Blanc, Philippe .
CHEST, 2009, 135 (02) :391-400
[5]   Effects of controlled mechanical ventilation on respiratory muscle contractile properties in rabbits [J].
Capdevila, X ;
Lopez, S ;
Bernard, N ;
Rabischong, E ;
Ramonatxo, M ;
Martinazzo, G ;
Prefaut, C .
INTENSIVE CARE MEDICINE, 2003, 29 (01) :103-110
[6]   PHRENIC-NERVE CONDUCTION STUDY IN NORMAL SUBJECTS [J].
CHEN, R ;
COLLINS, S ;
REMTULLA, H ;
PARKES, A ;
BOLTON, CF .
MUSCLE & NERVE, 1995, 18 (03) :330-335
[7]  
Gerscovich EO, 2001, J ULTRAS MED, V20, P597
[8]   Measuring diaphragm thickness with ultrasound in mechanically ventilated patients: feasibility, reproducibility and validity [J].
Goligher, Ewan C. ;
Laghi, Franco ;
Detsky, Michael E. ;
Farias, Paulina ;
Murray, Alistair ;
Brace, Deborah ;
Brochard, Laurent J. ;
Sebastien-Bolz, Steffen ;
Rubenfeld, Gordon D. ;
Kavanagh, Brian P. ;
Ferguson, Niall D. .
INTENSIVE CARE MEDICINE, 2015, 41 (04) :642-649
[9]   Ultrasound evaluation of the paralyzed diaphragm [J].
Gottesman, E ;
McCool, FD .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1997, 155 (05) :1570-1574
[10]   Diaphragm Muscle Thinning in Patients Who Are Mechanically Ventilated [J].
Grosu, Horiana B. ;
Lee, Young Im ;
Lee, Jarone ;
Eden, Edward ;
Eikermann, Matthias ;
Rose, Keith M. .
CHEST, 2012, 142 (06) :1455-1460