Comparison of user satisfaction and image quality of fixed and mobile camera systems for 3-dimensional image capture of edentulous patients: A pilot clinical study

被引:10
作者
Sailer, Irena [1 ]
Liu, Shiming [1 ,2 ]
Moerzinger, Roland [3 ]
Lancelle, Marcel [3 ]
Beeler, Thabo [4 ]
Gross, Markus [3 ]
Wu, Chenglei [3 ]
Fehmer, Vincent [5 ]
Srinivasan, Murali [6 ]
机构
[1] Univ Geneva, Univ Clin Dent Med, Div Fixed Prosthodont & Biomat, Geneva, Switzerland
[2] Peking Univ, Sch & Hosp Stomatol, Clin Div 1, Beijing, Peoples R China
[3] Fed Tech Inst Technol, Comp Graph Lab, Zurich, Switzerland
[4] Disney Res Zurich, Zurich, Switzerland
[5] Univ Geneva, Univ Clin Dent Med, Geneva, Switzerland
[6] Univ Geneva, Univ Clin Dent Med, Div Gerodontol & Removable Prosthodont, Geneva, Switzerland
关键词
ACCURACY; SMILE; RELIABILITY; PRECISION;
D O I
10.1016/j.prosdent.2018.04.005
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. An evaluation of user satisfaction and image quality of a novel handheld purpose-built mobile camera system for 3-dimensional (3D) facial acquisition is lacking. Purpose. The purpose of this pilot clinical study was to assess and compare the effectiveness between a handheld mobile camera system designed for facial acquisition and a fixed static camera arrangement by comparing the time effectiveness and the operator and participant preference for the 2 techniques of image capture. Material and methods. Completely edentulous participants (n=12: women=7, men=5; mean age: 74.6 years) were included in this pilot study. Images were captured with and without the prostheses in situ while maintaining "serious" and "full-smile" facial expressions. Images were captured using a mobile and a static system. The working times for the participant installation and image captures were recorded. Operator and participant perceptions of the entire experience were recorded by using visual analog scale questionnaires. Nonparametric tests were used for statistical analyses (alpha=.05). Results. The installation time was significantly shorter for the mobile system (static=24 +/- 13 seconds; mobile=10 +/- 10 seconds), but the differences in the image capture times were not statistically significant (static: 29 +/- 5 seconds; mobile: 40 +/- 18 seconds). Operator preference was in favor of the mobile system with regard to working time (P=.002), difficulty in using (installation: P=.002; handling: P=.045), and camera weight (P=.002); however, they preferred the static arrangement for image quality (P=.003) and comfort (P=.013). The participants rated the entire photographic experience favorably, and 10 of 12 participants preferred the static camera over the mobile one. Conclusion. Despite the complexity of the installation, the static system was evaluated better for image quality; the mobile system was easier in installation and handling. The operators preferred the mobile system, and the participants preferred the static system.
引用
收藏
页码:520 / 524
页数:5
相关论文
共 15 条
[1]   Reliability of digital orthodontic setups [J].
Barreto, Monica S. ;
Faber, Jorge ;
Vogel, Carlos J. ;
Araujo, Telma M. .
ANGLE ORTHODONTIST, 2016, 86 (02) :255-259
[2]   High-Quality Single-Shot Capture of Facial Geometry [J].
Beeler, Thabo ;
Bickel, Bernd ;
Beardsley, Paul ;
Sumner, Bob ;
Gross, Markus .
ACM TRANSACTIONS ON GRAPHICS, 2010, 29 (04)
[3]   A New Total Digital Smile Planning Technique (3D-DSP) to Fabricate CAD-CAM Mockups for Esthetic Crowns and Veneers [J].
Cattoni, F. ;
Mastrangelo, F. ;
Gherlone, E. F. ;
Gastaldi, G. .
INTERNATIONAL JOURNAL OF DENTISTRY, 2016, 2016
[4]   Dynamic Documentation of the Smile and the 2D/3D Digital Smile Design Process [J].
Coachman, Christian ;
Calamita, Marcelo Alexandre ;
Sesma, Newton .
INTERNATIONAL JOURNAL OF PERIODONTICS & RESTORATIVE DENTISTRY, 2017, 37 (02) :183-+
[5]  
Kau CH, 2010, AM J ORTHOD DENTOFAC, V137, DOI [10.1016/j.ajodo.2009.04.022, 10.1016/j.ajodo.2010.01.022]
[6]   Precision and Accuracy of the 3dMD Photogrammetric System in Craniomaxillofacial Application [J].
Luebbers, Heinz-Theo ;
Medinger, Laurent ;
Kruse, Astrid ;
Graetz, Klaus Wilhelm ;
Matthews, Felix .
JOURNAL OF CRANIOFACIAL SURGERY, 2010, 21 (03) :763-767
[7]   Accuracy of linear measurements using three imaging modalities: two lateral cephalograms and one 3D model from CBCT data [J].
Pittayapat, Pisha ;
Bornstein, Michael M. ;
Nozu Imada, Thais Sumie ;
Coucke, Wim ;
Lambrichts, Ivo ;
Jacobs, Reinhilde .
EUROPEAN JOURNAL OF ORTHODONTICS, 2015, 37 (02) :202-208
[8]   Evaluation of reproducibility and reliability of 3D soft tissue analysis using 3D stereophotogrammetry [J].
Plooij, J. M. ;
Swennen, G. R. J. ;
Rangel, F. A. ;
Maal, T. J. J. ;
Schutyser, F. A. C. ;
Bronkhorst, E. M. ;
Kuijpers-Jagtman, A. M. ;
Berge, S. J. .
INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2009, 38 (03) :267-273
[9]  
Sancho-Puchades M, 2015, INT J ESTHET DENT, V10, P374
[10]   3-Dimensional Facial Simulation in Orthognathic Surgery: Is It Accurate? [J].
Schendel, Stephen A. ;
Jacobson, Richard ;
Khalessi, Sadri .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2013, 71 (08) :1406-1414