Human Optical Axial Length and Defocus

被引:166
作者
Read, Scott A. [1 ]
Collins, Michael J. [1 ]
Sander, Beata P. [1 ]
机构
[1] Queensland Univ Technol, Sch Optometry, Contact Lens & Visual Opt Lab, Brisbane, Qld 4059, Australia
关键词
FORM-DEPRIVATION MYOPIA; CHOROIDAL BLOOD-FLOW; EYE GROWTH; INTRAOCULAR-PRESSURE; SPECTACLE LENSES; REFRACTIVE ERROR; PROTEOGLYCAN SYNTHESIS; OCULAR COMPENSATION; THICKNESS CHANGES; BLUR ADAPTATION;
D O I
10.1167/iovs.10-5457
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. To investigate the short-term influence of imposed monocular defocus on human optical axial length (the distance from anterior cornea to retinal pigment epithelium) and ocular biometrics. METHODS. Twenty-eight young adult subjects (14 myopes, 14 emmetropes) had eye biometrics measured before and 30 and 60 minutes after exposure to monocular (right eye) defocus. Four different monocular defocus conditions were tested, each on a separate day: control (no defocus), myopic (+3 D defocus), hyperopic (+3 D defocus), and diffuse (0.2 density Bangerter filter) defocus. The fellow eye was optimally corrected (no defocus). RESULTS. Imposed defocus caused small but significant changes in optical axial length (P < 0.0001). A significant increase in optical axial length (mean change, +8 +/- 14 mu m; P = 0.03) occurred after hyperopic defocus, and a significant reduction in optical axial length (mean change, -13 +/- 14 mu m; P = 0.0001) was found after myopic defocus. A small increase in optical axial length was observed after diffuse defocus (mean change, +6 +/- 13 mu m; P = 0.053). Choroidal thickness also exhibited some significant changes with certain defocus conditions. No significant difference was found between myopes and emmetropes in the changes in optical axial length or choroidal thickness with defocus. CONCLUSIONS. Significant changes in optical axial length occurred in human subjects after 60 minutes of monocular defocus. The bidirectional optical axial length changes observed in response to defocus implied the human visual system is capable of detecting the presence and sign of defocus and altering optical axial length to move the retina toward the image plane. (Invest Ophthalmol Vis Sci. 2010;51:6262-6269) DOI:10.1167/iovs.10-5457
引用
收藏
页码:6262 / 6269
页数:8
相关论文
共 71 条
[1]   A SIMPLE MECHANISM FOR EMMETROPIZATION WITHOUT CUES FROM ACCOMMODATION OR COLOR [J].
BARTMANN, M ;
SCHAEFFEL, F .
VISION RESEARCH, 1994, 34 (07) :873-876
[2]   In Vivo Human Choroidal Thickness Measurements: Evidence for Diurnal Fluctuations [J].
Brown, Jamin S. ;
Flitcroft, D. Ian ;
Ying, Gui-shuang ;
Francis, Ellie L. ;
Schmid, Gregor F. ;
Quinn, Graham E. ;
Stone, Richard A. .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2009, 50 (01) :5-12
[3]   A new optical low coherence reflectometry device for ocular biometry in cataract patients [J].
Buckhurst, P. J. ;
Wolffsohn, J. S. ;
Shah, S. ;
Naroo, S. A. ;
Davies, L. N. ;
Berrow, E. J. .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2009, 93 (07) :949-953
[4]   Evaluation of the Lenstar LS 900 non-contact biometer [J].
Cruysberg, L. P. J. ;
Doors, M. ;
Verbakel, F. ;
Berendschot, T. T. J. M. ;
De Brabander, J. ;
Nuijts, R. M. M. A. .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2010, 94 (01) :106-110
[5]   CALIBRATION OF THE CANON AUTOREF R-1 FOR CONTINUOUS MEASUREMENT OF ACCOMMODATION [J].
DAVIS, B ;
COLLINS, M ;
ATCHISON, D .
OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 1993, 13 (02) :191-198
[6]   Local changes in eye growth induced by imposed local refractive error despite active accommodation [J].
Diether, S ;
Schaeffel, F .
VISION RESEARCH, 1997, 37 (06) :659-668
[7]  
Drexler W, 1998, INVEST OPHTH VIS SCI, V39, P2140
[8]   Non-invasive biometric assessment of ocular rigidity in glaucoma patients and controls [J].
Ebneter, A. ;
Wagels, B. ;
Zinkernagel, M. S. .
EYE, 2009, 23 (03) :606-611
[9]   Temporal relationship of choroidal blood flow and thickness changes during recovery from form deprivation myopia in chicks [J].
Fitzgerald, MEC ;
Wildsoet, CF ;
Reiner, A .
EXPERIMENTAL EYE RESEARCH, 2002, 74 (05) :561-570
[10]  
GEE SS, 1988, OPHTHALMOLOGY, V95, P1276