Reliability and Validity of the CORE Sensor to Assess Core Body Temperature during Cycling Exercise

被引:39
|
作者
Verdel, Nina [1 ]
Podlogar, Tim [2 ,3 ,4 ]
Ciuha, Ursa [3 ]
Holmberg, Hans-Christer [5 ]
Debevec, Tadej [3 ,6 ]
Supej, Matej [1 ,6 ]
机构
[1] Mid Sweden Univ, Swedish Winter Sports Res Ctr, S-83125 Ostersund, Sweden
[2] Univ Primorska, Fac Hlth Sci, Izola 6310, Slovenia
[3] Jozef Stefan Inst, Dept Automat Biocybernet & Robot, Ljubljana 1000, Slovenia
[4] Human Performance Ctr, Ljubljana 1000, Slovenia
[5] Lulea Univ Technol, Dept Hlth Med & Rehabil, S-97187 Lulea, Sweden
[6] Univ Ljubljana, Fac Sport, Ljubljana 1000, Slovenia
基金
欧盟地平线“2020”;
关键词
validity; reliability; core body temperature; rectal temperature; CORE sensor; cycling; non-invasive; INTESTINAL TEMPERATURE; RECTAL TEMPERATURE; TELEMETRY PILL; HEAT ILLNESS; ESOPHAGEAL; DEVICES; SKIN;
D O I
10.3390/s21175932
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Monitoring core body temperature (T-c) during training and competitions, especially in a hot environment, can help enhance an athlete's performance, as well as lower the risk for heat stroke. Accordingly, a noninvasive sensor that allows reliable monitoring of T-c would be highly beneficial in this context. One such novel non-invasive sensor was recently introduced onto the market (CORE, greenTEG, Rumlang, Switzerland), but, to our knowledge, a validation study of this device has not yet been reported. Therefore, the purpose of this study was to evaluate the validity and reliability of the CORE sensor. In Study I, 12 males were subjected to a low-to-moderate heat load by performing, on two separate occasions several days apart, two identical 60-min bouts of steady-state cycling in the laboratory at 19 degrees C and 30% relative humidity. In Study II, 13 males were subjected to moderate-to-high heat load by performing 90 min of cycling in the laboratory at 31 degrees C and 39% relative humidity. In both cases the core body temperatures indicated by the CORE sensor were compared to the corresponding values obtained using a rectal sensor (T-rec). The first major finding was that the reliability of the CORE sensor is acceptable, since the mean bias between the two identical trials of exercise (0.02 degrees C) was not statistically significant. However, under both levels of heat load, the body temperature indicated by the CORE sensor did not agree well with T-rec, with approximately 50% of all paired measurements differing by more than the predefined threshold for validity of <= 0.3 degrees C. In conclusion, the results obtained do not support the manufacturer's claim that the CORE sensor provides a valid measure of core body temperature.
引用
收藏
页数:13
相关论文
共 50 条
  • [41] Core Temperature and Metabolic Responses After Carbohydrate Intake During Exercise at 30°C
    Horswill, Craig A.
    Stofan, John R.
    Lovett, Shannon C.
    Hannasch, Chris
    JOURNAL OF ATHLETIC TRAINING, 2008, 43 (06) : 585 - 591
  • [42] Validity of Core Temperature Measurements at 3 Rectal Depths During Rest, Exercise, Cold-Water Immersion, and Recovery
    Miller, Kevin C.
    Hughes, Lexie E.
    Long, Blaine C.
    Adams, William M.
    Casa, Douglas J.
    JOURNAL OF ATHLETIC TRAINING, 2017, 52 (04) : 332 - 338
  • [43] Individualized estimation of human core body temperature using noninvasive measurements
    Laxminarayan, Srinivas
    Rakesh, Vineet
    Oyama, Tatsuya
    Kazman, Josh B.
    Yanovich, Ran
    Ketko, Itay
    Epstein, Yoram
    Morrison, Shawnda
    Reifman, Jaques
    JOURNAL OF APPLIED PHYSIOLOGY, 2018, 124 (06) : 1387 - 1402
  • [44] The validity of tympanic and exhaled breath temperatures for core temperature measurement
    Flouris, Andreas D.
    Cheung, Stephen S.
    PHYSIOLOGICAL MEASUREMENT, 2010, 31 (05) : N35 - N42
  • [45] Conductive cooling of the forehead during exercise attenuates a rise in core temperature
    Carrasco, M. A.
    SCIENCE & SPORTS, 2013, 28 (05) : 303 - 306
  • [46] Non-steroidal anti-inflammatory drugs on core body temperature during exercise: A systematic review
    Emerson, Dawn M.
    Chen, Stephen Cl
    Kelly, Melani R.
    Parnell, Bryant
    Torres-McGehee, Toni M.
    JOURNAL OF EXERCISE SCIENCE & FITNESS, 2021, 19 (02) : 127 - 133
  • [47] POWER RELATIVE TO BODY MASS BEST PREDICTS CHANGE IN CORE TEMPERATURE DURING EXERCISE-HEAT STRESS
    Gibson, Oliver R.
    Willmott, Ashley G. B.
    James, Carl A.
    Hayes, Mark
    Maxwell, Neil S.
    JOURNAL OF STRENGTH AND CONDITIONING RESEARCH, 2017, 31 (02) : 403 - 414
  • [48] Effects of core stability and feedback music on upper body mediolateral movements during cycling
    Jeong, Siwoo
    Kim, Si-hyun
    Park, Kyue-nam
    BMC SPORTS SCIENCE MEDICINE AND REHABILITATION, 2024, 16 (01)
  • [49] Effects of core stability and feedback music on upper body mediolateral movements during cycling
    Siwoo Jeong
    Si-hyun Kim
    Kyue-nam Park
    BMC Sports Science, Medicine and Rehabilitation, 16
  • [50] Wearable Personal Core Body Temperature Measurement Considering Individual Differences and Dynamic Tissue Blood Perfusion
    Shan, Chengcheng
    Hu, Jiawen
    Zou, Jincheng
    Zhang, Aili
    IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2022, 26 (05) : 2158 - 2168