Reliability and Validity of the CORE Sensor to Assess Core Body Temperature during Cycling Exercise

被引:39
|
作者
Verdel, Nina [1 ]
Podlogar, Tim [2 ,3 ,4 ]
Ciuha, Ursa [3 ]
Holmberg, Hans-Christer [5 ]
Debevec, Tadej [3 ,6 ]
Supej, Matej [1 ,6 ]
机构
[1] Mid Sweden Univ, Swedish Winter Sports Res Ctr, S-83125 Ostersund, Sweden
[2] Univ Primorska, Fac Hlth Sci, Izola 6310, Slovenia
[3] Jozef Stefan Inst, Dept Automat Biocybernet & Robot, Ljubljana 1000, Slovenia
[4] Human Performance Ctr, Ljubljana 1000, Slovenia
[5] Lulea Univ Technol, Dept Hlth Med & Rehabil, S-97187 Lulea, Sweden
[6] Univ Ljubljana, Fac Sport, Ljubljana 1000, Slovenia
基金
欧盟地平线“2020”;
关键词
validity; reliability; core body temperature; rectal temperature; CORE sensor; cycling; non-invasive; INTESTINAL TEMPERATURE; RECTAL TEMPERATURE; TELEMETRY PILL; HEAT ILLNESS; ESOPHAGEAL; DEVICES; SKIN;
D O I
10.3390/s21175932
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Monitoring core body temperature (T-c) during training and competitions, especially in a hot environment, can help enhance an athlete's performance, as well as lower the risk for heat stroke. Accordingly, a noninvasive sensor that allows reliable monitoring of T-c would be highly beneficial in this context. One such novel non-invasive sensor was recently introduced onto the market (CORE, greenTEG, Rumlang, Switzerland), but, to our knowledge, a validation study of this device has not yet been reported. Therefore, the purpose of this study was to evaluate the validity and reliability of the CORE sensor. In Study I, 12 males were subjected to a low-to-moderate heat load by performing, on two separate occasions several days apart, two identical 60-min bouts of steady-state cycling in the laboratory at 19 degrees C and 30% relative humidity. In Study II, 13 males were subjected to moderate-to-high heat load by performing 90 min of cycling in the laboratory at 31 degrees C and 39% relative humidity. In both cases the core body temperatures indicated by the CORE sensor were compared to the corresponding values obtained using a rectal sensor (T-rec). The first major finding was that the reliability of the CORE sensor is acceptable, since the mean bias between the two identical trials of exercise (0.02 degrees C) was not statistically significant. However, under both levels of heat load, the body temperature indicated by the CORE sensor did not agree well with T-rec, with approximately 50% of all paired measurements differing by more than the predefined threshold for validity of <= 0.3 degrees C. In conclusion, the results obtained do not support the manufacturer's claim that the CORE sensor provides a valid measure of core body temperature.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] Lowering of resting core temperature during acclimation is influenced by exercise stimulus
    Kampmann, Bernhard
    Broede, Peter
    Schuette, Martin
    Griefahn, Barbara
    EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2008, 104 (02) : 321 - 327
  • [22] Body Core Temperature Assessment in Emergency Care Departments
    Daanen, Hein A. M.
    Hoitinga, Gercora
    Kruijt, David J.
    Koning, Kevin S.
    Verheijen, Pooh P.
    de Baas, Sanne I. M.
    Bergsma, Anouk R.
    Snethlage, Cathelijne E.
    Al -Bander, Iman
    Teunissen, Lennart P. J.
    JOURNAL OF EMERGENCY MEDICINE, 2024, 66 (03) : e277 - e283
  • [23] Comparison of Rectal and Aural Core Body Temperature Thermometry in Hyperthermic, Exercising Individuals: A Meta-Analysis
    Huggins, Robert
    Glaviano, Neal
    Negishi, Naoki
    Casa, Douglas J.
    Hertel, Jay
    JOURNAL OF ATHLETIC TRAINING, 2012, 47 (03) : 329 - 338
  • [24] Insulated skin temperature as a measure of core body temperature for individuals wearing CBRN protective clothing
    Richmond, V. L.
    Wilkinson, D. M.
    Blacker, S. D.
    Horner, F. E.
    Carter, J.
    Havenith, G.
    Rayson, M. P.
    PHYSIOLOGICAL MEASUREMENT, 2013, 34 (11) : 1531 - 1543
  • [25] Measurement of horse core body temperature
    Green, AR
    Gates, SG
    Lawrence, LM
    JOURNAL OF THERMAL BIOLOGY, 2005, 30 (05) : 370 - 377
  • [26] Validity of inner canthus temperature recorded by infrared thermography as a non-invasive surrogate measure for core temperature at rest, during exercise and recovery
    Fernandes, Alex Andrade
    Moreira, Danilo Gomes
    Jose Brito, Ciro
    da Silva, Cristiano Diniz
    Sillero-Quintana, Manuel
    Pimenta, Eduardo Mendonca
    Bach, Aaron J. E.
    Garcia, Emerson Silami
    Bouzas Marins, Joao Carlos
    JOURNAL OF THERMAL BIOLOGY, 2016, 62 : 50 - 55
  • [27] Validity of the estimated core temperature algorithm during real-world prolonged walking exercise under warm ambient conditions
    Peggen, Mandy A. G.
    Bongers, Coen C. W. G.
    de Korte, Johannus Q.
    Veenstra, Bertil J.
    Levels, Koen
    Hopman, Maria T. E.
    Eijsvogels, Thijs M. H.
    JOURNAL OF THERMAL BIOLOGY, 2024, 125
  • [28] Study of Validity and Reliability of the Turkish Version of the Core Bereavement Items
    Selvi, Yavuz
    Ozturk, Rabia Iclal
    Agargun, Mehmed Yucel
    Besiroglu, Lutfullah
    Cilli, Ali Savas
    NOROPSIKIYATRI ARSIVI-ARCHIVES OF NEUROPSYCHIATRY, 2011, 48 (02): : 129 - 134
  • [29] Core body temperature during menopausal hot flushes
    Freedman, RR
    Woodward, S
    FERTILITY AND STERILITY, 1996, 65 (06) : 1141 - 1144
  • [30] A Novel Miniaturized Sandwich-Like Sensor for Continuous Measurement of Core Body Temperature
    Ren, Xianglin
    Zhou, Congcong
    Ye, Xuesong
    IEEE SENSORS JOURNAL, 2022, 22 (17) : 16742 - 16749