Rapid qualitative and quantitative analysis of chlortetracycline hydrochloride and tetracycline hydrochloride in environmental samples based on terahertz frequency-domain spectroscopy

被引:25
作者
Wang, Yongmei [1 ]
Wang, Qiang [2 ]
Zhao, Zongshan [1 ]
Liu, Aifeng [1 ]
Tian, Yong [1 ]
Qin, Jianyuan [3 ]
机构
[1] Chinese Acad Sci, Qingdao Inst Bioenergy & Bioproc Technol, CAS Key Lab Biobased Mat, Qingdao 266101, Peoples R China
[2] Qingdao Agr Univ, Coll Chem & Pharmaceut, Qingdao 266109, Peoples R China
[3] China Jiliang Univ, Ctr Terahertz Res, Hangzhou 310018, Peoples R China
基金
中国国家自然科学基金; 中国博士后科学基金;
关键词
Terahertz spectroscopy; Frequency domain; Chlortetracycline hydrochloride; Tetracycline hydrochloride; Environmental samples; ANTIBIOTICS; POLLUTION; MILK; SIZE; TIME; HPLC;
D O I
10.1016/j.talanta.2018.08.008
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Owing to the advantages of transient, broadband, low-energy, transmission and high frequency accuracy, terahertz frequency domain spectroscopy (THz-FDS) has been introduced and pioneered for determining chlortetracycline hydrochloride (CCH) and tetracycline hydrochloride (TCH) in environmental samples, such as chicken, rice and soils. Their THz fingerprint spectra were located in the range of 0.4-1.1 THz, with the peaks at 0.49, 0.60, 0.76, 0.90 and 1.03 THz for CCH and at 0.52, 0.67, 0.79, 0.92 and 1.05 THz for TCH, respectively. By simple pressing treatment, dry soil, chicken and rice samples spiked with standards can be used for direct analysis. For the quantitative analysis, partial least squares regression (PLSR) algorithms were utilized for optimizing the analysis accuracy, calculation and prediction. Lower root mean square error of cross validation (RMSECV < 0.1689), calibration (RMSEC < 0.0623), prediction (RMSEP < 0.1280) and higher correlation coefficient (R > 0.9089) for these two compounds in soil, chicken and rice samples have been obtained, Our results indicated that THz-FDS combined with PLSR model could be a useful analytical technique for monitoring CCH and TCH in environmental samples.
引用
收藏
页码:284 / 291
页数:8
相关论文
共 39 条
  • [1] Waveguide interrogated optical immunosensor (WIOS) for detection of sulfonamide antibiotics in milk
    Adrian, Javier
    Pasche, Stephanie
    Diserens, Jean-Marc
    Sanchez-Baeza, Francisco
    Gao, Hui
    Marco, M. -Pilar
    Voirin, Guy
    [J]. BIOSENSORS & BIOELECTRONICS, 2009, 24 (11) : 3340 - 3346
  • [2] [Anonymous], PHYSICS
  • [3] Terahertz pulsed spectroscopy of freshly excised human breast cancer
    Ashworth, Philip C.
    Pickwell-MacPherson, Emma
    Provenzano, Elena
    Pinder, Sarah E.
    Purushotham, Anand D.
    Pepper, Michael
    Wallace, Vincent P.
    [J]. OPTICS EXPRESS, 2009, 17 (15): : 12444 - 12454
  • [4] Bailon-Perez M. I., 2009, J CHROMATOGR A, V1216
  • [5] Balan E, 2001, AM MINERAL, V86, P1321
  • [6] Multiple component analysis of cigarette smoke using THz spectroscopy, comparison with standard chemical analytical methods
    Bigourd, D.
    Cuisset, A.
    Hindle, F.
    Matton, S.
    Bocquet, R.
    Mouret, G.
    Cazier, F.
    Dewaele, D.
    Nouali, H.
    [J]. APPLIED PHYSICS B-LASERS AND OPTICS, 2007, 86 (04): : 579 - 586
  • [7] Brinkmann S., 2016, P 2016 41 INT C INFR, P1
  • [8] Effect of Molecular Size and Particle Shape on the Terahertz Absorption of a Homologous Series of Tetraalkylammoniunn Salts
    Burnett, Andrew D.
    Kendrick, John
    Russell, Christopher
    Christensen, Jeppe
    Cunningham, John E.
    Pearson, Arwen R.
    Linfield, Edmund H.
    Davies, A. Giles
    [J]. ANALYTICAL CHEMISTRY, 2013, 85 (16) : 7926 - 7934
  • [9] Application of terahertz time-domain spectroscopy combined with chemometrics to quantitative analysis of imidacloprid in rice samples
    Chen, Zewei
    Zhang, Zhuoyong
    Zhu, Ruohua
    Xiang, Yuhong
    Yang, Yuping
    Harrington, Peter B.
    [J]. JOURNAL OF QUANTITATIVE SPECTROSCOPY & RADIATIVE TRANSFER, 2015, 167 : 1 - 9
  • [10] Frisch M., 1995, GAUSSIAN 09