Measurement of lesion area and volume by three-dimensional spoiled gradient-echo MR imaging in osteonecrosis of the femoral head

被引:26
|
作者
Kishida, Y
Nishii, T
Sugano, N
Nakanishi, K
Sakai, T
Miki, H
Ochi, T
Yoshikawa, H
机构
[1] Osaka Univ, Sch Med, Dept Orthopaed Surg, Suita, Osaka 5640871, Japan
[2] Osaka Univ, Sch Med, Dept Radiol, Suita, Osaka 5640871, Japan
关键词
femoral head; three-dimensional spoiled gradient-echo (3D SPGR) imaging; volume; area; osteonecrosis;
D O I
10.1016/S0736-0266(03)00043-3
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The purpose of this investigation is to evaluate the diagnostic ability of three-dimensional spoiled gradient-echo (3D SPGR) magnetic resonance (MR) imaging in cases of osteonecrosis of the femoral head (ONFH), and to determine the accuracy of 3D SPGR imaging in area and volume measurement of ONFH. T1-weighted spin-echo (SE) and 3D SPGR imaging were performed on 20 femoral heads obtained from patients with ONFH. After MR imaging, the femoral heads were cut parallel to the imaging plane and were evaluated histologically. Areas and volumes of necrotic lesions were measured with a computer program and the deviation between MR images and anatomical measurements was evaluated. A low signal intensity band on 3D SPGR MR images was observed in all femoral heads and corresponded histologically to repaired marrow with viable fibrous mesenchymal tissue. The area proximate to the low band area coincided with the necrotic region. Both area and volume measurements by T1-weighted SE and 3D SPGR images showed a strong correlation to histological measurements. The discrepancies between histological and imaging results were minimal in 3D SPGR imaging, especially at the anterior and posterior portions of the femoral head. Three-dimensional SPGR imaging provides more accurate measurements of the area and volume of a necrotic lesion than T1-weighted SE imaging. (C) 2003 Orthopaedic Research Society. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:850 / 858
页数:9
相关论文
共 16 条
  • [1] Mechanics of femoral head osteonecrosis using three-dimensional finite element method
    Yang, JW
    Koo, KH
    Lee, MC
    Yang, P
    Noh, MD
    Kim, SY
    Kim, KI
    Ha, YC
    Joun, MS
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2002, 122 (02) : 88 - 92
  • [2] MEASUREMENT OF BRAIN ACTIVITY WITH BOLUS ADMINISTRATION OF CONTRAST AGENT AND GRADIENT-ECHO MR IMAGING
    ZIGUN, JR
    FRANK, JA
    BARRIOS, FA
    JONES, DW
    FOO, TKF
    MOONEN, CTW
    PRESS, DZ
    WEINBERGER, DR
    RADIOLOGY, 1993, 186 (02) : 353 - 356
  • [3] MR-based three-dimensional presentation of cartilage thickness in the femoral head
    Nakanishi, K
    Tanaka, H
    Sugano, N
    Sato, Y
    Ueguchi, T
    Kubota, T
    Tamura, S
    Nakamura, H
    EUROPEAN RADIOLOGY, 2001, 11 (11) : 2178 - 2183
  • [4] Comparison of Three-Dimensional Pseudo-continuous Arterial Spin Labeling Perfusion Imaging With Gradient-Echo and Spin-Echo Dynamic Susceptibility Contrast MRI
    Wong, Alex M.
    Yan, Feng-Xian
    Liu, Ho-Ling
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2014, 39 (02) : 427 - 433
  • [5] Femoral head volume indicates the severity of developmental dysplasia of the hip by a method using three-dimensional magnetic resonance imaging
    Fukiage, Kenichi
    Fukuda, Atsushi
    Harada, Yuki
    Suzuki, Shigeo
    Futami, Tohru
    JOURNAL OF PEDIATRIC ORTHOPAEDICS-PART B, 2015, 24 (04): : 286 - 290
  • [6] Research on Three-dimensional Cartilage Thickness Measurement of Femoral Head in Magnetic Resonance Images
    Cao Yu
    Zhao Jie
    Cheng Yuanzhi
    PROCEEDINGS OF THE 2009 INTERNATIONAL CONFERENCE ON COMPUTATIONAL INTELLIGENCE AND NATURAL COMPUTING, VOL II, 2009, : 265 - +
  • [7] The effect of necrotic lesion size and rotational degree on the stress reduction in transtrochanteric rotational osteotomy for femoral head osteonecrosis - a three-dimensional finite-element simulation
    Lee, Mel S.
    Tai, Ching-Lung
    Senan, Vinesh
    Shih, Chun-Hsiung
    Lo, Shi-Wei
    Chen, Weng-Pin
    CLINICAL BIOMECHANICS, 2006, 21 (09) : 969 - 976
  • [8] Three-dimensional finite element analysis of silk protein rod implantation after core decompression for osteonecrosis of the femoral head
    Huang, Liangta
    Chen, Feiyan
    Wang, Siqun
    Wei, Yibing
    Huang, Gangyong
    Chen, Jie
    Shi, Jingsheng
    Naidu, Rajeev K.
    Xia, Jun
    Tao, Tiger H.
    BMC MUSCULOSKELETAL DISORDERS, 2019, 20 (01)
  • [9] Three-dimensional finite element analysis of silk protein rod implantation after core decompression for osteonecrosis of the femoral head
    Liangta Huang
    Feiyan Chen
    Siqun Wang
    Yibing Wei
    Gangyong Huang
    Jie Chen
    Jingsheng Shi
    Rajeev K. Naidu
    Jun Xia
    Tiger H. Tao
    BMC Musculoskeletal Disorders, 20
  • [10] Measurement of right ventricular volume from biplane contrast ventriculograms: Validation by cast and three-dimensional echo
    Sheehan, FH
    Bolson, EL
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2004, 62 (01) : 46 - 51