Maximally reliable spatial filtering of steady state visual evoked potentials

被引:42
作者
Dmochowski, Jacek P. [1 ]
Greaves, Alex S. [1 ]
Norcia, Anthony M. [1 ]
机构
[1] Stanford Univ, Dept Psychol, Stanford, CA 94305 USA
关键词
SSVEP; EEG; Reliability; Coherence; Spatial filtering; CANONICAL CORRELATION-ANALYSIS; SELECTIVE ATTENTION; RESPONSES; EEG; RECOGNITION; SIGNALS; MODEL; FIELD;
D O I
10.1016/j.neuroimage.2014.12.078
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Due to their high signal-to-noise ratio (SNR) and robustness to artifacts, steady state visual evoked potentials (SSVEPs) are a popular technique for studying neural processing in the human visual system. SSVEPs are conventionally analyzed at individual electrodes or linear combinations of electrodes which maximize some variant of the SNR. Here we exploit the fundamental assumption of evoked responses - reproducibility across trials - to develop a technique that extracts a small number of high SNR, maximally reliable SSVEP components. This novel spatial filtering method operates on an array of Fourier coefficients and projects the data into a low-dimensional space in which the trial-to-trial spectral covariance is maximized. When applied to two sample data sets, the resulting technique recovers physiologically plausible components (i.e., the recovered topographies match the lead fields of the underlying sources) while drastically reducing the dimensionality of the data (i.e., more than 90% of the trial-to-trial reliability is captured in the first four components). Moreover, the proposed technique achieves a higher SNR than that of the single-best electrode or the Principal Components. We provide a freely-available MATLAB implementation of the proposed technique, herein termed "Reliable Components Analysis". (C) 2015 Elsevier Inc. All rights reserved.
引用
收藏
页码:63 / 72
页数:10
相关论文
共 51 条
  • [1] V1 is not uniquely identified by polarity reversals of responses to upper and lower visual field stimuli
    Ales, Justin M.
    Yates, Jacob L.
    Norcia, Anthony M.
    [J]. NEUROIMAGE, 2010, 52 (04) : 1401 - 1409
  • [2] The technique, validity and clinical use of the sweep VEP
    Almoqbel, Fahad
    Leat, Susan J.
    Irving, Elizabeth
    [J]. OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2008, 28 (05) : 393 - 403
  • [3] Bottom-Up Biases in Feature-Selective Attention
    Andersen, Soren K.
    Mueller, Matthias M.
    Martinovic, Jasna
    [J]. JOURNAL OF NEUROSCIENCE, 2012, 32 (47) : 16953 - 16958
  • [4] [Anonymous], 1989, Evoked potentials and evoked magnetic fields in science and medicine
  • [5] An online multi-channel SSVEP-based brain-computer interface using a canonical correlation analysis method
    Bin, Guangyu
    Gao, Xiaorong
    Yan, Zheng
    Hong, Bo
    Gao, Shangkai
    [J]. JOURNAL OF NEURAL ENGINEERING, 2009, 6 (04)
  • [6] Optimizing spatial filters for robust EEG single-trial analysis
    Blankertz, Benjamin
    Tomioka, Ryota
    Lemm, Steven
    Kawanabe, Motoaki
    Mueller, Klaus-Robert
    [J]. IEEE SIGNAL PROCESSING MAGAZINE, 2008, 25 (01) : 41 - 56
  • [7] New insights into the noise reduction Wiener filter
    Chen, Jingdong
    Benesty, Jacob
    Huang, Yiteng
    Doclo, Simon
    [J]. IEEE TRANSACTIONS ON AUDIO SPEECH AND LANGUAGE PROCESSING, 2006, 14 (04): : 1218 - 1234
  • [8] Cheng Ming, 1999, Proceedings of the First Joint BMES/EMBS Conference. 1999 IEEE Engineering in Medicine and Biology 21st Annual Conference and the 1999 Annual Fall Meeting of the Biomedical Engineering Society (Cat. No.99CH37015), DOI 10.1109/IEMBS.1999.802747
  • [9] Finding brain oscillations with power dependencies in neuroimaging data
    Daehne, Sven
    Nikulin, Vadim V.
    Ramirez, David
    Schreier, Peter J.
    Mueller, Klaus-Robert
    Haufe, Stefan
    [J]. NEUROIMAGE, 2014, 96 : 334 - 348
  • [10] Joint decorrelation, a versatile tool for multichannel data analysis
    de Cheveigne, Alain