Common-Mode-Free Bidirectional Three-Phase PFC-Rectifier for Non-Isolated EV Charger

被引:6
|
作者
Strothmann, B. [1 ]
Schafmeister, F. [1 ]
Bocker, J. [1 ]
机构
[1] Paderborn Univ, Power Elect & Elect Drives, D-33098 Paderborn, Germany
来源
2021 THIRTY-SIXTH ANNUAL IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION (APEC 2021) | 2021年
关键词
Three-phase four-wire; OBC; V2G; PFC; CM; EV charger; balancing circuit; VOLTAGE; BOOST;
D O I
10.1109/APEC42165.2021.9487462
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
DC-DC converters for on-board chargers (OBC) of electrical vehicles are usually galvanically isolated allowing modular single-phase PFC front-end solutions, but require transformers which are more bulky, costly and lossy than inductors of non-isolated DC-DCs. Furthermore, for vehicle-to-grid applications, bidirectional converters with transformers are generally more complex and have a higher count on semiconductor switches than transformerless solutions. However, when using non-isolated DC-DC converters within an OBC, the large common-mode (CM) capacitance comprising capacitive parasitics of the traction battery as well as explicit Y-capacitors connecting the high-voltage DC-system (RV-system) within specific RV-loads to ground has to be considered. For the PFC front-end stage, when supplied from the three-phase mains this means that generation of high-frequency and high-amplitude CM voltages, as it is common e.g. with the conventional six-switch full-bridge converter, has to be strictly avoided. For this reason, a modified topology is suggested leading to a different mode of operation and to a very low common-mode noise behaviour: The three-phase four-wire full-bridge PFC with split DC-link, whose midpoint is connected to the mains neutral provides very stable potentials at the DC-link rails and therefore it can be classified as Zero-CM-topology. For dedicated single-phase operation, as required for most OBC, an additional balancing leg may be added to the topology to reduce the required DC-link capacitance and allow non-electrolytic capacitors. The function of the bidirectional Zero-CM three-phase four-wire full-bridge PFC was verified by simulation and on an 11 kW-laboratory sample. The power factor is above 0.999 and an efficiency of 98 % is measured.
引用
收藏
页码:2783 / 2790
页数:8
相关论文
共 14 条
  • [11] A Hybrid PWM Pattern of Three-Phase Buck PFC Converter With Low Common-Mode Voltage and Low Voltage Stress
    Su, Sheng
    Chen, Qiang
    Ma, Runsen
    Zhang, Xing
    Ma, Mingyao
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2024, 39 (12) : 15452 - 15456
  • [12] A step-down isolated three-phase IGBT boost PFC rectifier using a novel control algorithm with a novel start-up method
    Kose, Huseyin
    Aydemir, M. Timur
    TURKISH JOURNAL OF ELECTRICAL ENGINEERING AND COMPUTER SCIENCES, 2021, 29 (02) : 978 - 993
  • [13] Performance Analysis and Improvement of PI-Type Current Controller in Digital Average Current Mode Controlled Three-Phase Six-Switch Boost PFC Rectifier
    Geng, Xinghai
    Xu, Jianping
    Wang, Lei
    Chen, Zhengge
    Huang, Rui
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2022, 37 (07) : 7871 - 7882
  • [14] Single-Stage Non-Isolated Multiport Y-Converter for Interlinking 400 V DC Microgrids With the Three-Phase AC Grid
    Farag, Ahmed Y.
    Biadene, Davide
    Caldognetto, Tommaso
    Mattavelli, Paolo
    IEEE OPEN JOURNAL OF POWER ELECTRONICS, 2024, 5 : 1432 - 1445