Image-guided robotic radiosurgery in a rat glioma model

被引:6
作者
Psarros, TG
Mickey, B
Gall, K
Gilio, J
Delp, J
White, C
Drees, J
Willis, M
Pistemmna, D
Giller, CA
机构
[1] Univ Texas, SW Med Ctr, SW Med Sch, Dept Neurosurg, Dallas, TX 75390 USA
[2] Univ Texas, Dept Radiat Oncol, SW Med Sch, Dallas, TX 75390 USA
[3] Univ Texas, Dept Pathol, SW Med Sch, Dallas, TX 75390 USA
关键词
radiosurgery; 9L glioma; cyberknife;
D O I
10.1055/s-2004-830076
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Despite the proven efficacy of radiosurgery for the treatment of brain tumors, limited histological information is available after treatment that might allow a better understanding of the relationship between radiation dose, the volume treated, and the response of the surrounding brain to the delivered radiation. The use of an animal model could provide the opportunity to clarify these relationships and answer several other key questions arising in clinical practice. We show here that treatment of small animals with radiosurgery is feasible using a robotically controlled linear accelerator, which offers the advantages of radiosurgery and preserves the potential for fractionated regimens without rigid immobilization. Specifically, we demonstrate the use of a robotically driven linear accelerator to provide radiosurgical treatment to a rat brain tumor model.
引用
收藏
页码:266 / 272
页数:7
相关论文
共 29 条
[1]   Image-guided robotic radiosurgery [J].
Adler, JR ;
Murphy, MJ ;
Chang, SD ;
Hancock, SL .
NEUROSURGERY, 1999, 44 (06) :1299-1306
[2]  
Altschuler E, 1992, Neurosurg Clin N Am, V3, P61
[3]   Effect of implant dose/volume and surgical resection on survival in a rat glioma brachytherapy model: Implications for brain tumor therapy [J].
Bampoe, J ;
Glen, J ;
Mackenzie, I ;
Porter, P ;
Bernstein, M .
NEUROSURGERY, 1997, 41 (06) :1374-1383
[4]  
BARKER M, 1973, CANCER RES, V33, P976
[5]   BCNU AND X-RAY THERAPY OF INTRA-CEREBRAL 9L RAT-TUMORS [J].
BARKER, M ;
DEEN, DF ;
BAKER, DG .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1979, 5 (09) :1581-1583
[7]   Enhancement of cerebral diseases: How much contrast agent is enough? Comparison of 0.1, 0.2, and 0.3 mmol/kg gadoteridol at 0.2 T with 0.1 mmol/kg gadoteridol at 1.5 T [J].
Brekenfeld, C ;
Foert, E ;
Hundt, W ;
Kenn, W ;
Lodeann, KP ;
Gehl, HB .
INVESTIGATIVE RADIOLOGY, 2001, 36 (05) :266-275
[8]   COMPUTERIZED CRANIAL TOMOGRAPHY IN THE EVALUATION OF PITUITARY-TUMORS IN RATS [J].
CASANUEVA, FF ;
GORDON, WL ;
FRIESEN, HG .
ACTA ENDOCRINOLOGICA, 1983, 103 (04) :487-491
[9]   An analysis of the accuracy of the Cyberknife: A robotic nameless stereotactic radiosurgical system [J].
Chang, SD ;
Main, W ;
Martin, DP ;
Gibbs, IC ;
Heilbrun, MP .
NEUROSURGERY, 2003, 52 (01) :140-146
[10]  
Dilmanian FA, 2002, NEURO-ONCOLOGY, V4, P26, DOI 10.1093/neuonc/4.1.26