Effects of Pore Fluids and Sand Particles on Electrochemical Characteristics of Sandy Soil Containing Soluble Sodium Salt

被引:6
作者
Xie, Ruizhen [1 ,2 ]
Han, Pengju [2 ]
Wang, Xiaoyuan [2 ]
Li, Boqiong [1 ]
He, Bin [2 ]
Ma, Fuli [2 ]
Bai, Xiaohong [2 ]
机构
[1] Jinzhong Univ, Mech Inst, Jinzhong 030619, Peoples R China
[2] Taiyuan Univ Technol, Dept Civil Engn, Taiyuan 030024, Peoples R China
基金
中国国家自然科学基金;
关键词
EIS; sandy soil; corrosivity; equivalent circuit; CORROSION BEHAVIOR; PIPELINE STEEL; STRESS; COPPER;
D O I
10.20964/2020.04.03
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
The electrochemical impedance spectroscopy (EIS) characteristics of sandy soil and pore fluids containing different concentrations of NaCl, Na2SO4 or NaHCO3 were tested and comprehensively analysed. The equivalent circuit fitting and analysis results show that the basic equivalent circuit of the sandy soil system is circuit (1) R(C(R(Q(RW))))). The EIS of different sandy soils show their respective characteristics. Compared with those of the pore fluids, the radius of the capacitive loop and the peak of phase angle for the sandy soil is small, showing the high corrosivity of sandy soil. The sand particles facilitate low-frequency processes and hinder high-frequency processes. In the high-frequency region, the three conductive paths in the sandy soil are mostly in the conducting state, and the corresponding modulus is large. At the frequencies of 10(0)similar to 10(2) Hz, the peak of phase angle for the sandy soil containing NaCl, Na2SO4 or NaHCO3 is greatly affected by the concentration of the pore fluid, which may be caused by the porous structure and the state of the "liquid bridge".
引用
收藏
页码:3543 / 3562
页数:20
相关论文
共 45 条
[21]   Field experiment of stress corrosion cracking behavior of high strength pipeline steels in typical soil environments [J].
Liu, Z. Y. ;
Li, Q. ;
Cui, Z. Y. ;
Wu, W. ;
Li, Z. ;
Du, C. W. ;
Li, X. G. .
CONSTRUCTION AND BUILDING MATERIALS, 2017, 148 :131-139
[22]  
Lu N, 2012, Unsaturated soil mechanics
[23]   Study of the Initial Corrosion of X80 Steel in a Saturated Saline Soil Co-Contaminated with Cl-, SO42- and HCO3- [J].
Ma, Fuli ;
Xie, Ruizhen ;
Han, Pengju ;
Bai, Xiaohong .
INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2018, 13 (06) :5396-5412
[24]  
Maite O., 2015, PROCEDIA MAT SCI, V9, P2015
[25]  
Mi F.L., 2018, SCI TECHNOL ENG, V18, P148
[26]  
Orazem M. E., 2014, ELECTROCHEM IMPEDANC
[27]  
Osada M., 2016, Zairyo-to-Kankyo, V65, P378
[28]   Electrochemical study on the corrosion rate of X52 steel exposed to different soils [J].
Quej-Ake, L. M. ;
Contreras, A. .
ANTI-CORROSION METHODS AND MATERIALS, 2018, 65 (01) :97-106
[29]   Copper-graphene oxide composite coatings for corrosion protection of mild steel in 3.5% NaCl [J].
Raghupathy, Y. ;
Kamboj, Anshul ;
Rekha, M. Y. ;
Rao, Narasimha N. P. ;
Srivastava, Chandan .
THIN SOLID FILMS, 2017, 636 :107-115
[30]  
Ran Q., 1990, J SICHUAN TEACH COLL, V11, P1990