Computational analysis of spray type counter flow liquid desiccant dehumidifier

被引:0
作者
Ahmed, M. Ijas [1 ]
Vignesh, R. [1 ]
Kumar, L. Gangadhara Kiran [1 ]
机构
[1] NIT Calicut, Dept Mech Engn, Calicut 673601, Kerala, India
关键词
Liquid desiccant; 3D model; Spray type; Counter flow; Mass transfer; PERFORMANCE;
D O I
10.1016/j.matpr.2020.10.888
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The liquid desiccant air conditioning system (LDAC) is considered as the substitute for the conventional air conditioning system mainly because of its energy-saving characteristics. The dehumidifier is one of the most important components in LDAC, therefore, it is chosen as the system for analysis. A 3D computational model of the spray type dehumidifier with counter flow configuration was created and analysed its mass transfer characteristics for two different cases. 2D CFD models studied by various researchers failed to elaborate on the actual flow process. In order to fill this gap 3D model was created and the analysis was conducted to investigate the influence of flow rate of air and desiccant on the mass transfer performance of the dehumidifier. Air and desiccant flow rate have direct influence on the mass transfer performance of the dehumidifier. In this study, the dehumidification performance is evaluated through the simulation by increasing the desiccant flow rate and simultaneously reducing the airflow rate and the results are observed. ANSYS-FLUENT (R) software is used for the current analysis. The increase in desiccant flow rate and decrease in air flow rate tends to improve the change in humidity ratio (specific moisture removal) from 4.2 to 6.3 g/kg of dry air. The temperature variation of solution keeps increasing as the moisture transfer increases. The rise in temperature of the solution is higher than the air during moisture transfer due to exothermic process. Similarly the equilibrium humidity ratio of solution increased due to moisture absorption during dehumidification, which indicates the decrease in solution concentration during dehumidification. The heating of solution and air during dehumidification will affect the moisture transfer rate, which can be avoided by adding a cooling unit to the liquid desiccant system. (c) 2019 Elsevier Ltd. Selection and Peer-review under responsibility of the scientific committee of the International Mechanical Engineering Congress 2019: Materials Science.
引用
收藏
页码:9820 / 9826
页数:7
相关论文
共 11 条
  • [1] Badrakia H. C, 2015, PERFORMANCE REV AQUE, V2, P12
  • [2] Experimental comparative study on lithium chloride and calcium chloride desiccants
    Bouzenada, S.
    Kaabi, A. N.
    Frainkin, L.
    Salmon, T.
    Leonard, A.
    [J]. 7TH INTERNATIONAL CONFERENCE ON AMBIENT SYSTEMS, NETWORKS AND TECHNOLOGIES (ANT 2016) / THE 6TH INTERNATIONAL CONFERENCE ON SUSTAINABLE ENERGY INFORMATION TECHNOLOGY (SEIT-2016) / AFFILIATED WORKSHOPS, 2016, 83 : 718 - 725
  • [3] Studying the performance of a liquid desiccant indirect evaporative cooling system
    Cui, Xin
    Liu, Yanhua
    Liu, Yilin
    Jin, Liwen
    Zhao, Min
    Meng, Xiangzhao
    [J]. INNOVATIVE SOLUTIONS FOR ENERGY TRANSITIONS, 2019, 158 : 5659 - 5665
  • [4] Mathematical modeling and parametric study of liquid desiccant system with internally-cooled dehumidifier
    Hendijani, Arash Doustani
    Gilani, Neda
    [J]. THERMAL SCIENCE AND ENGINEERING PROGRESS, 2018, 5 : 213 - 229
  • [5] Studying the heat and mass transfer process of liquid desiccant for dehumidification and cooling
    Islam, M. R.
    Alan, S. W. L.
    Chua, K. J.
    [J]. APPLIED ENERGY, 2018, 221 : 334 - 347
  • [6] Experimental study on performance of celdek packed liquid desiccant dehumidifier
    Kumar, Rakesh
    Asati, A. K.
    [J]. HEAT AND MASS TRANSFER, 2016, 52 (09) : 1821 - 1832
  • [7] Study on an internally-cooled liquid desiccant dehumidifier with CFD model
    Luo, Yimo
    Chen, Yi
    Yang, Hongxing
    Wang, Yuanhao
    [J]. APPLIED ENERGY, 2017, 194 : 399 - 409
  • [8] Experimental investigation and parametric studies on structured packing chamber based liquid desiccant dehumidification and regeneration systems
    Naik, B. Kiran
    Muthukumar, P.
    [J]. BUILDING AND ENVIRONMENT, 2019, 149 : 330 - 348
  • [9] Experimental investigation of convective heat transfer coefficient on nano particles mixture used in automobile radiator based on mass flow rate
    Sathish, T.
    Sabariraj, R., V
    Muthukumar, K.
    Karthick, S.
    [J]. MATERIALS TODAY-PROCEEDINGS, 2020, 33 : 2524 - 2529
  • [10] TEACHING LEARNING OPTIMIZATION AND NEURAL NETWORK FOR THE EFFECTIVE PREDICTION OF HEAT TRANSFER RATES IN TUBE HEAT EXCHANGERS
    Thanikodi, Sathish
    Singaravelu, Dinesh Kumar
    Devarajan, Chandramohan
    Venkatraman, Vijayan
    Rathinavelu, Venkatesh
    [J]. THERMAL SCIENCE, 2020, 24 (01): : 575 - 581