Measurement of Peri-Implant Bone Width with and without Metal Artifact Reduction Algorithm Using Two Cone-Beam Computed Tomography Software Programs

被引:2
作者
Hedayatipanah, Morad [1 ]
Salemi, Fatemeh [2 ]
Kamyari, Naser [3 ]
Yalpanian, Ashkan [4 ]
机构
[1] Hamadan Univ Med Sci, Fac Dent, Dept Periodont, Hamadan, Hamadan, Iran
[2] Hamadan Univ Med Sci, Fac Dent, Dept Oral & Maxillofacial Radiol, Hamadan, Hamadan, Iran
[3] Abadan Fac Med Sci, Dept Biostat, Abadan, Iran
[4] Hamadan Univ Med Sci, Fac Dent, Hamadan, Hamadan, Iran
来源
PESQUISA BRASILEIRA EM ODONTOPEDIATRIA E CLINICA INTEGRADA | 2021年 / 21卷
关键词
Cone-Beam Computed Tomography; Dental Implants; Artifacts; CT; ACCURACY;
D O I
10.1590/pboci.2021.118
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective: To assess the effect of metal artifact reduction (MAR) algorithm of two cone-beam computed tomography (CBCT) software programs on the accuracy of peri-implant bone width measurements. Material and Methods: This in vitro study evaluated 35 bovine rib bone blocks measuring 8 x 8 x 11 mm. Titanium implants were inserted in bone blocks and placed in a wax model of mandible. CBCT scans were obtained with ProMax 3D and Cranex 3D CBCT systems with and without the MAR algorithm. The width of buccal and lingual bone plates surrounding the implant was measured on CBCT scans by two observers. The Cronbach's alpha was calculated to assess inter-observer agreement. The area under the curve (AUC), sensitivity and specificity values were calculated and compared. Results: The two observers had an excellent agreement. The accuracy of Cranex 3D was higher than that of ProMax 3D (p<0.05). Both CBCT systems showed higher accuracy when the MAR algorithm was not used (p<0.05). Both CBCT systems showed higher accuracy for measuring the width of the lingual plate than buccal plate (p<0.05). Conclusion: The application of MAR algorithm did not notably increase the measurement accuracy in any CBCT system. Cranex 3D showed generally higher measurement accuracy than ProMax 3D.
引用
收藏
页数:10
相关论文
共 50 条
[41]   Accuracy of cone-beam computed tomography, dental magnetic resonance imaging, and intraoral radiography for detecting peri-implant bone defects at single zirconia implantsAn in vitro study [J].
Hilgenfeld, Tim ;
Juerchott, Alexander ;
Deisenhofer, Ulrich Karl ;
Krisam, Johannes ;
Rammelsberg, Peter ;
Heiland, Sabine ;
Bendszus, Martin ;
Schwindling, Franz Sebastian .
CLINICAL ORAL IMPLANTS RESEARCH, 2018, 29 (09) :922-930
[42]   Accuracy of cone beam computed tomography in assessing peri-implant bone defect regeneration: a histologically controlled study in dogs [J].
Fienitz, Tim ;
Schwarz, Frank ;
Ritter, Lutz ;
Dreiseidler, Timo ;
Becker, Juergen ;
Rothamel, Daniel .
CLINICAL ORAL IMPLANTS RESEARCH, 2012, 23 (07) :882-887
[43]   Metal artifact reduction in cone beam computed tomography using forward projected reconstruction information [J].
Meilinger, Manuel ;
Schmidgunst, Christian ;
Schuetz, Oliver ;
Lang, Elmer W. .
ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2011, 21 (03) :174-182
[44]   Evaluation of the efficacy of a metal artifact reduction algorithm in different cone beam computed tomography scanning parameters [J].
Queiroz, Polyane Mazucatto ;
Groppo, Francisco Carlos ;
Oliveira, Matheus Lima ;
Haiter-Neto, Francisco ;
Freitas, Deborah Queiroz .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY, 2017, 123 (06) :729-734
[45]   Effect of metal artifact reduction software on image quality of C-arm cone-beam computed tomography during intracranial aneurysm treatment [J].
Enomoto, Yukiko ;
Yamauchi, Keita ;
Asano, Takahiko ;
Otani, Katharina ;
Iwama, Toru .
INTERVENTIONAL NEURORADIOLOGY, 2018, 24 (03) :303-308
[46]   Intra- and inter-observer agreements in detecting peri-implant bone defects between periapical radiography and cone beam computed tomography: A clinical study [J].
Zhang, Chu-Nan ;
Zhu, Yu ;
Fan, Lin-Feng ;
Zhang, Xiao ;
Jiang, Yin-Hua ;
Gu, Ying-Xin .
JOURNAL OF DENTAL SCIENCES, 2021, 16 (03) :948-956
[47]   Performance of different cone-beam computed tomography scan modes with and without metal artifact reduction in detection of recurrent dental caries under various restorative materials [J].
Abesi, Farida ;
Talachi, Fatemehzahra ;
Ezoji, Fariba .
POLISH JOURNAL OF RADIOLOGY, 2024, 89 :e281-e291
[48]   Assessment of buccal marginal alveolar peri-implant and periodontal defects using a cone beam CT system with and without the application of metal artefact reduction mode [J].
Kamburoglu, K. ;
Kolsuz, E. ;
Murat, S. ;
Eren, H. ;
Yuksel, S. ;
Paksoy, C. S. .
DENTOMAXILLOFACIAL RADIOLOGY, 2013, 42 (08)
[49]   Comparison of the different voxel sizes in the estimation of peri-implant fenestration defects using cone beam computed tomography: an ex vivo study [J].
Kurt, Mehmet Hakan ;
Bagis, Nilsun ;
Evli, Cengiz ;
Atakan, Cemal ;
Orhan, Kaan .
INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2020, 6 (01)
[50]   Digital planning for two-implant-supported overdenture and bone reduction guide using cone-beam computed tomography: Simple features for predictable outcomes [J].
Meneghetti, Priscila Ceolin ;
Sabri, Hamoun ;
Dastouri, Ebrahim ;
Pereira, Rafael Martins Afonso ;
Teixeira, Wendel ;
Wang, Hom-Lay ;
Mendonca, Gustavo .
JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2023, 32 (04) :361-370