Measurement of Peri-Implant Bone Width with and without Metal Artifact Reduction Algorithm Using Two Cone-Beam Computed Tomography Software Programs

被引:2
作者
Hedayatipanah, Morad [1 ]
Salemi, Fatemeh [2 ]
Kamyari, Naser [3 ]
Yalpanian, Ashkan [4 ]
机构
[1] Hamadan Univ Med Sci, Fac Dent, Dept Periodont, Hamadan, Hamadan, Iran
[2] Hamadan Univ Med Sci, Fac Dent, Dept Oral & Maxillofacial Radiol, Hamadan, Hamadan, Iran
[3] Abadan Fac Med Sci, Dept Biostat, Abadan, Iran
[4] Hamadan Univ Med Sci, Fac Dent, Hamadan, Hamadan, Iran
来源
PESQUISA BRASILEIRA EM ODONTOPEDIATRIA E CLINICA INTEGRADA | 2021年 / 21卷
关键词
Cone-Beam Computed Tomography; Dental Implants; Artifacts; CT; ACCURACY;
D O I
10.1590/pboci.2021.118
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective: To assess the effect of metal artifact reduction (MAR) algorithm of two cone-beam computed tomography (CBCT) software programs on the accuracy of peri-implant bone width measurements. Material and Methods: This in vitro study evaluated 35 bovine rib bone blocks measuring 8 x 8 x 11 mm. Titanium implants were inserted in bone blocks and placed in a wax model of mandible. CBCT scans were obtained with ProMax 3D and Cranex 3D CBCT systems with and without the MAR algorithm. The width of buccal and lingual bone plates surrounding the implant was measured on CBCT scans by two observers. The Cronbach's alpha was calculated to assess inter-observer agreement. The area under the curve (AUC), sensitivity and specificity values were calculated and compared. Results: The two observers had an excellent agreement. The accuracy of Cranex 3D was higher than that of ProMax 3D (p<0.05). Both CBCT systems showed higher accuracy when the MAR algorithm was not used (p<0.05). Both CBCT systems showed higher accuracy for measuring the width of the lingual plate than buccal plate (p<0.05). Conclusion: The application of MAR algorithm did not notably increase the measurement accuracy in any CBCT system. Cranex 3D showed generally higher measurement accuracy than ProMax 3D.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Effect of field of view in the detection of chemically created peri-implant bone defects in bovine ribs using cone beam computed tomography: an in vitro study
    Pinheiro, Lucas Rodrigues
    Gaia, Bruno Felipe
    Oliveira de Sales, Marcelo Augusto
    Umetsubo, Otavio Shoiti
    Santos, Oseas, Jr.
    Paraiso Cavalcanti, Marcelo Gusmao
    [J]. ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY, 2015, 120 (01): : 69 - 77
  • [32] Effect of metal artefact reduction level on the assessment of dental implant positioning by cone-beam computed tomography
    Capel, Camila Porto
    da Motta, Raphael Jurca Goncalves
    Pauwels, Ruben
    Gaeta-Araujo, Hugo
    Oliveira-Santos, Christiano
    Tirapelli, Camila
    [J]. DENTOMAXILLOFACIAL RADIOLOGY, 2024, 53 (04) : 233 - 239
  • [33] Study of available bone for interforaminal implant treatment using cone-beam computed tomography
    Madrigal, Cristina
    Ortega, Ricardo
    Meniz, Cristina
    Lopez-Quiles, Juan
    [J]. MEDICINA ORAL PATOLOGIA ORAL Y CIRUGIA BUCAL, 2008, 13 (05): : E307 - E312
  • [34] Effectiveness of Periapical Radiography Versus Cone Beam Computed Tomography with Different Kilovoltage Settings in the Detection of Chemically Created Peri-implant Bone Defects: An In Vitro Study
    Pinheiro, Lucas Rodrigues
    Scarfe, William C.
    de Oliveira Sales, Marcelo Augusto
    Gaia, Bruno Felipe
    Gonzalez Cortes, Arthur Rodriguez
    Paraiso Cavalcanti, Marcelo Gusmao
    [J]. INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2017, 32 (04) : 741 - 750
  • [35] Impact of the spatial orientation of the patient's head, metal artifact reduction, and tube current on cone-beam computed tomography artifact expression adjacent to a dental implant: A laboratory study using a simulated surgical guide
    -Costa, Matheus Barros
    -Candido, Julia Ramos Barros
    -Oliveira, Matheus Sampaio
    Freitas, Deborah Queiroz
    Sverzut, Alexander Tadeu
    Oliveira, Matheus L.
    [J]. IMAGING SCIENCE IN DENTISTRY, 2024, 54 (02) : 191 - 199
  • [36] The influence of metal artifact reduction on the trueness of registration of a cone-beam computed tomography scan with an intraoral scan in the presence of severe restoration artifact
    Biun, John
    Dudhia, Raahib
    Arora, Himanshu
    [J]. JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2024, 33 (07): : 700 - 705
  • [37] Accuracy evaluation of cone beam computed tomography applied to measure peri-implant bone thickness in living patients: an ex vivo and in vivo experiment
    Yanhua Lan
    Xiaoyuan Huang
    Mingxing Fan
    Huazhen Yu
    Zhijian Xie
    Yiqun Zhou
    [J]. Clinical Oral Investigations, 2022, 26 : 6347 - 6359
  • [38] Quantitative analysis of metal artifact reduction using the auto-edge counting method in cone-beam computed tomography
    Kim, Young Hyun
    Lee, Chena
    Han, Sang-Sun
    Jeon, Kug Jin
    Choi, Yoon Joo
    Lee, Ari
    [J]. SCIENTIFIC REPORTS, 2020, 10 (01)
  • [39] The relationship between dental implant stability and trabecular bone structure using cone-beam computed tomography
    Kang, Se-Ryong
    Bok, Sung-Chul
    Choi, Soon-Chul
    Lee, Sam-Sun
    Heo, Min-Suk
    Huh, Kyung-Hoe
    Kim, Tae-Il
    Yi, Won-Jin
    [J]. JOURNAL OF PERIODONTAL AND IMPLANT SCIENCE, 2016, 46 (02) : 116 - 127
  • [40] Effect of exposure parameters of cone beam computed tomography on metal artifact reduction around the dental implants in various bone densities
    Shokri, Abbas
    Jamalpour, Mohammad Reza
    Khavid, Atefeh
    Mohseni, Zeinab
    Sadeghi, Masoud
    [J]. BMC MEDICAL IMAGING, 2019, 19 (1)