Measurement of Peri-Implant Bone Width with and without Metal Artifact Reduction Algorithm Using Two Cone-Beam Computed Tomography Software Programs

被引:2
作者
Hedayatipanah, Morad [1 ]
Salemi, Fatemeh [2 ]
Kamyari, Naser [3 ]
Yalpanian, Ashkan [4 ]
机构
[1] Hamadan Univ Med Sci, Fac Dent, Dept Periodont, Hamadan, Hamadan, Iran
[2] Hamadan Univ Med Sci, Fac Dent, Dept Oral & Maxillofacial Radiol, Hamadan, Hamadan, Iran
[3] Abadan Fac Med Sci, Dept Biostat, Abadan, Iran
[4] Hamadan Univ Med Sci, Fac Dent, Hamadan, Hamadan, Iran
来源
PESQUISA BRASILEIRA EM ODONTOPEDIATRIA E CLINICA INTEGRADA | 2021年 / 21卷
关键词
Cone-Beam Computed Tomography; Dental Implants; Artifacts; CT; ACCURACY;
D O I
10.1590/pboci.2021.118
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective: To assess the effect of metal artifact reduction (MAR) algorithm of two cone-beam computed tomography (CBCT) software programs on the accuracy of peri-implant bone width measurements. Material and Methods: This in vitro study evaluated 35 bovine rib bone blocks measuring 8 x 8 x 11 mm. Titanium implants were inserted in bone blocks and placed in a wax model of mandible. CBCT scans were obtained with ProMax 3D and Cranex 3D CBCT systems with and without the MAR algorithm. The width of buccal and lingual bone plates surrounding the implant was measured on CBCT scans by two observers. The Cronbach's alpha was calculated to assess inter-observer agreement. The area under the curve (AUC), sensitivity and specificity values were calculated and compared. Results: The two observers had an excellent agreement. The accuracy of Cranex 3D was higher than that of ProMax 3D (p<0.05). Both CBCT systems showed higher accuracy when the MAR algorithm was not used (p<0.05). Both CBCT systems showed higher accuracy for measuring the width of the lingual plate than buccal plate (p<0.05). Conclusion: The application of MAR algorithm did not notably increase the measurement accuracy in any CBCT system. Cranex 3D showed generally higher measurement accuracy than ProMax 3D.
引用
收藏
页数:10
相关论文
共 50 条
[21]   Metal Artifact Reduction in Cone-Beam Computed Tomography for Head and Neck Radiotherapy [J].
Korpics, Mark ;
Johnson, Paul ;
Patel, Rakesh ;
Surucu, Murat ;
Choi, Mehee ;
Emami, Bahman ;
Roeske, John C. .
TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2016, 15 (06) :NP88-NP94
[22]   Analysis of peri-implant bone defects by using cone beam computed tomography (CBCT): an integrative review [J].
J. A. Costa ;
J. M. Mendes ;
F. Salazar ;
J. J. Pacheco ;
P. Rompante ;
M. I. Câmara .
Oral Radiology, 2023, 39 :455-466
[23]   Blooming artifact reduction using different cone-beam computed tomography software to analyze endodontically treated teeth with intracanal posts [J].
Gregoris Rabelo, Luiz Eduardo ;
Bueno, Mike dos Reis ;
Correa da Costa, Marcus Vinicius ;
de Musis, Carlo Ralph ;
de Araujo Estrela, Cyntia Rodrigues ;
Guedes, Orlando Aguirre ;
Gavini, Giulio ;
Estrela, Carlos .
COMPUTERS IN BIOLOGY AND MEDICINE, 2021, 136 (136)
[24]   Evaluation of a metal artifact reduction algorithm and an adaptive image noise optimization filter in the estimation of peri-implant fenestration defects using cone beam computed tomography: an in-vitro study [J].
Nilsun Bagis ;
Mehmet Hakan Kurt ;
Cengiz Evli ;
Melike Camgoz ;
Cemal Atakan ;
Hilal Peker Ozturk ;
Kaan Orhan .
Oral Radiology, 2022, 38 :325-335
[25]   Effect of a metal artifact reduction algorithm on cone-beam computed tomography scans of titanium and zirconia implants within and outside the field of view [J].
Soltani, Parisa ;
Moaddabi, Amirhossein ;
Mehdizadeh, Mojdeh ;
Bateni, Mohammad Reza ;
Naghdi, Sepehr ;
Cernera, Mariangela ;
Mirrashidi, Farnaz ;
Azimipour, Mohammad Matin ;
Spagnuolo, Gianrico ;
Valletta, Alessandra .
IMAGING SCIENCE IN DENTISTRY, 2024, 54 (04) :313-318
[26]   The efficacy of metal artifact reduction (MAR) algorithm in cone-beam computed tomography on the diagnostic accuracy of fenestration and dehiscence around dental implants [J].
Sheikhi, Mahnaz ;
Behfarnia, Parichehr ;
Mostajabi, Mahdis ;
Nasri, Naeimeh .
JOURNAL OF PERIODONTOLOGY, 2020, 91 (02) :209-214
[27]   A Comparison of Cone Beam Computed Tomography and Panoramic Radiography in the Detection of Mechanical Created Peri-implant Bone Defects [J].
Naje, Ahmed R. ;
F-Al Drobie, Ban ;
Falah, Ali .
JOURNAL OF RESEARCH IN MEDICAL AND DENTAL SCIENCE, 2019, 7 (01) :222-225
[28]   Accuracy evaluation of cone beam computed tomography applied to measure peri-implant bone thickness in living patients: an ex vivo and in vivo experiment [J].
Lan, Yanhua ;
Huang, Xiaoyuan ;
Fan, Mingxing ;
Yu, Huazhen ;
Xie, Zhijian ;
Zhou, Yiqun .
CLINICAL ORAL INVESTIGATIONS, 2022, 26 (10) :6347-6359
[29]   Comparison of cone-beam computed tomography and digital panoramic radiography for detecting peri-implant alveolar bone changes using trabecular micro-structure analysis [J].
Magat, Guldane ;
Oncu, Elif ;
Ozcan, Sevgi ;
Orhan, Kaan .
JOURNAL OF THE KOREAN ASSOCIATION OF ORAL AND MAXILLOFACIAL SURGEONS, 2022, 48 (01) :41-49
[30]   Diagnostic performance of cone beam computed tomography in assessing peri-implant bone loss: A systematic review [J].
Pelekos, Georgios ;
Acharya, Aneesha ;
Tonetti, Maurizio S. ;
Bornstein, Michael M. .
CLINICAL ORAL IMPLANTS RESEARCH, 2018, 29 (05) :443-464