Effect of ProTaper Gold, Self-Adjusting File, and XP-endo Shaper Instruments on Dentinal Microcrack Formation: A Micro-computed Tomographic Study

被引:46
|
作者
Bayram, H. Melike [1 ]
Bayram, Emre [1 ]
Ocak, Mert [2 ]
Uygun, Ahmet Demirhan [3 ]
Celik, Hakan Hamdi [2 ]
机构
[1] Gaziosmanpasa Univ, Fac Dent, Dept Endodont, TR-60200 Tokat, Turkey
[2] Hacettepe Univ, Fac Med, Dept Anat, Ankara, Turkey
[3] Recep Tayyip Erdogan Univ, Fac Dent, Dept Endodont, Rize, Turkey
关键词
Dentinal defects; micro-computed tomographic imaging; microcracks; nickel-titanium file system; root canal preparation; ROOT-CANAL PREPARATIONS; CRACK FORMATION; UNIVERSAL; RECIPROCATION; MOVEMENT; SYSTEMS;
D O I
10.1016/j.joen.2017.02.005
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Introduction: The aim of the present study was to evaluate the frequency of dentinal microcracks observed after root canal preparation with ProTaper Universal (PTU; Dentsply Tulsa Dental Specialties, Tulsa, OK), ProTaper Gold (PTG; Dentsply Tulsa Dental Specialties), Self Adjusting File (SAF; ReDent Nova, Ra'anana, Israel), and XP-endo Shaper (XP; FKG Dentaire, La Chaux-de-Fonds, Switzerland) instruments using micro computed tomographic (CT) analysis. Methods: Forty extracted human mandibular premolars having single-canal and straight root were randomly assigned to 4 experimental groups (n = 10) according to the different nickel titanium systems used for root canal preparation: PTU, PTG, SAF, and XP. In the SAF and XP groups, the canals were first prepared with a K-file until #25 at the working length, and then the SAF or XP files were used. The specimens were scanned using high-resolution micro computed tomographic imaging before and after root canal preparation. Afterward, preoperative and postoperative cross-sectional images of the teeth were screened to identify the presence of dentinal defects. For each group, the number of microcracks was determined as a percentage rate. The McNemar test was used to determine significant differences before and after instrumentation. The level of significance was set at P < .05. Results: The PTU system significantly increased the percentage rate of microcracks compared with preoperative specimens (P < .05). No new dentinal microcracks were observed in the PTG, SAF, or XP groups. Conclusions: Root canal preparations with the PTG, SAF, and XP systems did not induce the formation of new dentinal microcracks on straight root canals of mandibular premolars.
引用
收藏
页码:1166 / 1169
页数:4
相关论文
共 23 条
  • [1] Effect of Reciproc blue, XP-endo shaper, and WaveOne gold instruments on dentinal microcrack formation: A micro-computed tomographic evaluation
    Aydin, Zeliha Ugur
    Keskin, Neslihan Busra
    Ozyurek, Taha
    MICROSCOPY RESEARCH AND TECHNIQUE, 2019, 82 (06) : 856 - 860
  • [2] Evaluation of XP-endo Shaper, Reciproc Blue, and ProTaper Universal NiTi Systems on Dentinal Microcrack Formation Using Micro-Computed Tomography
    Aksoy, Cagman
    Keris, Elif Yildizer
    Yaman, Sis Darendeliler
    Ocak, Mert
    Geneci, Ferhat
    Celik, Hakan Hamdi
    JOURNAL OF ENDODONTICS, 2019, 45 (03) : 338 - 342
  • [3] Micro-computed Tomographic Assessment on the Effect of ProTaper Next and Twisted File Adaptive Systems on Dentinal Cracks
    De-Deus, Gustavo
    Belladonna, Felipe Goncalves
    Souza, Erick Miranda
    Nogueira Leal Silva, Emmanuel Joao
    Neves, Aline de Almeida
    Alves, Haimon
    Lopes, Ricardo Tadeu
    Versiani, Marco Aurelio
    JOURNAL OF ENDODONTICS, 2015, 41 (07) : 1116 - 1119
  • [4] Dentinal Microcrack Formation after Root Canal Instrumentation by XP-Endo Shaper and ProTaper Universal: A Microcomputed Tomography Evaluation
    Alkahtany, Sarah M.
    Al-Madi, Ebtissam M.
    INTERNATIONAL JOURNAL OF DENTISTRY, 2020, 2020
  • [5] TRUShape Versus XP-endo Shaper: A Micro-computed Tomographic Assessment and Comparative Study of the Shaping Ability-An In Vitro Study
    Perez Morales, Maria de las Nieves
    Gonzalez Sanchez, Jose Antonio
    Olivieri Fernandez, Juan Gonzalo
    Laperre, Kjell
    Abella Sans, Francesc
    Jaramillo, David E.
    Duran-Sindreu Terol, Fernando
    JOURNAL OF ENDODONTICS, 2020, 46 (02) : 271 - 276
  • [6] Micro-computed Tomographic Evaluation of Dentinal Microcracks after Preparation of Curved Root Canals with ProTaper Gold, WaveOne Gold, and ProTaper Next Instruments
    Miguens-Vila, Ramon
    Martin-Biedma, Benjamin
    De-Deus, Gustavo
    Belladonna, Felipe G.
    Pena-Lopez, Alejandro
    Castelo-Baz, Pablo
    JOURNAL OF ENDODONTICS, 2021, 47 (02) : 309 - 314
  • [7] Shaping ability of XP-endo Shaper and ProTaper Next in long oval-shaped canals: a micro-computed tomography study
    Velozo, C.
    Silva, S.
    Almeida, A.
    Romeiro, K.
    Vieira, B.
    Dantas, H.
    Sousa, F.
    De Albuquerque, D. S.
    INTERNATIONAL ENDODONTIC JOURNAL, 2020, 53 (07) : 998 - 1006
  • [8] Dentinal Microcrack Formation during Root Canal Preparations by Different NiTi Rotary Instruments and the Self-Adjusting File
    Yoldas, Oguz
    Yilmaz, Sehnaz
    Atakan, Gokhan
    Kuden, Cihan
    Kasan, Zeynep
    JOURNAL OF ENDODONTICS, 2012, 38 (02) : 232 - 235
  • [9] Micro-computed Tomographic Evaluation of the Shaping Ability of XP-endo Shaper, iRaCe, and EdgeFile Systems in Long Oval-shaped Canals
    Versiani, Marco A.
    Carvalho, Kleber K. T.
    Mazzi-Chaves, Jardel F.
    Sousa-Neto, Manoel D.
    JOURNAL OF ENDODONTICS, 2018, 44 (03) : 489 - 495
  • [10] Micro-computed tomographic assessment of dentinal microcrack formation in straight and curved root canals in extracted teeth prepared with hand, rotary and reciprocating instruments
    Martins, J. C. L. G. D.
    Oliveira, B. P.
    Duarte, D. A.
    Antonino, A. C. D.
    Aguiar, C. M.
    Camara, A. C.
    INTERNATIONAL ENDODONTIC JOURNAL, 2021, 54 (08) : 1362 - 1368