Assessment of dental implant stability using resonance frequency analysis and quantitative ultrasound methods

被引:10
作者
Heriveaux, Yoann [1 ]
Vayron, Romain [2 ]
Fraulob, Manon [1 ]
Lomami, Hugues Albini [1 ]
Lenormand, Camille [1 ]
Haiat, Guillaume [1 ]
机构
[1] CNRS, Lab Modelisat & Simulat Multi Echelle, Creteil, France
[2] Univ Polytech Hauts France, Lab Automat Mecan & Informat Ind & Humaines, Valenciennes, France
基金
欧洲研究理事会;
关键词
Implant stability; Bone-Implant contact; Quantitative ultrasound; Resonance frequency analysis; Dental implants; BIOMECHANICAL STABILITY; TITANIUM IMPLANTS; WAVE-PROPAGATION; BONE-FORMATION; OSSEOINTEGRATION; INTERFACE; SIMULATION; CONTACT; REFLECTION; SURFACES;
D O I
10.2186/jpr.JPR_D_20_00052
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: Quantitative ultrasound (QUS) and resonance frequency analyses (RFA) are promising methods to assess the stability of dental implants. The aim of this in vivo preclinical study is to compare the results obtained with these two techniques with the bone-implant contact (BIC) ratio, which is the gold standard to assess dental implant stability. Methods: Twenty-two identical dental implants were inserted in the tibia and femur of 12 rabbits, which were sacrificed after different healing durations (0, 4. 8 and 13 weeks). For each implant, the ultrasonic indicator (LI) and the implant stability quotient (ISQ) were retrieved just before the animal sacrifice using the QUS and RFA techniques, respectively. Histomorphometric analyses were carried out to estimate the hone-implant contact ratio. Results: UI values were found to be better correlated to BIC values (R-2=0.47) compared to ISQ values (R-2=0.39 for measurements in one direction and R-2=0.18 for the other direction). which were shown to be dependent on the direction of measurements. Errors realized on the UI were around 3.3 times lower to the ones realized on the ISQ. Conclusions: QUS provide a better estimation of dental implant stability compared to RFA. This study paves the way for the future clinical development of a medical device aiming at assessing dental implant stability in a patient-specific manner. Clinical studies should confirm these results in the future.
引用
收藏
页码:421 / 427
页数:7
相关论文
共 55 条
[1]   Early bone formation adjacent to rough and turned endosseous implant surfaces - An experimental study in the dog [J].
Abrahamsson, I ;
Berglundh, T ;
Linder, E ;
Lang, NP ;
Lindhe, J .
CLINICAL ORAL IMPLANTS RESEARCH, 2004, 15 (04) :381-392
[2]   Implant stability in relation to osseointegration: an experimental study in the Labrador dog [J].
Abrahamsson, Ingemar ;
Linder, Elena ;
Lang, Niklaus P. .
CLINICAL ORAL IMPLANTS RESEARCH, 2009, 20 (03) :313-318
[3]   Correlation between resonance frequency, insertion torque and bone-implant contact in self-cutting threaded implants [J].
Acil, Yahya ;
Sievers, Jan ;
Guelses, Aydin ;
Ayna, Mustafa ;
Wiltfang, Joerg ;
Terheyden, Hendrik .
ODONTOLOGY, 2017, 105 (03) :347-353
[4]   OSSEOINTEGRATED ORAL IMPLANTS - A SWEDISH MULTICENTER STUDY OF 8139 CONSECUTIVELY INSERTED NOBELPHARMA IMPLANTS [J].
ALBREKTSSON, T ;
DAHL, E ;
ENBOM, L ;
ENGEVALL, S ;
ENGQUIST, B ;
ERIKSSON, AR ;
FELDMANN, G ;
FREIBERG, N ;
GLANTZ, PO ;
KJELLMAN, O ;
KRISTERSSON, L ;
KVINT, S ;
KONDELL, PA ;
PALMQUIST, J ;
WERNDAHL, L ;
ASTRAND, P .
JOURNAL OF PERIODONTOLOGY, 1988, 59 (05) :287-296
[5]   Validity and clinical significance of biomechanical testing of implant/bone interface [J].
Aparicio, Carlos ;
Lang, Niklaus R. ;
Rangert, Bo .
CLINICAL ORAL IMPLANTS RESEARCH, 2006, 17 :2-7
[6]  
Bodelón OG, 2016, INT J IMPLANT DENT, V2, DOI 10.1186/s40729-016-0051-5
[7]  
Buser D, 2002, INT J PERIODONT REST, V22, P109
[8]   Osteoblastic differentiation of human mesenchymal stem cells with platelet lysate [J].
Chevallier, Nathalie ;
Anagnostou, Fani ;
Zilber, Sebastien ;
Bodivit, Gwellaouen ;
Maurin, Sophie ;
Barrault, Aurelie ;
Bierling, Philippe ;
Hernigou, Philippe ;
Layrolle, Pierre ;
Rouard, Helene .
BIOMATERIALS, 2010, 31 (02) :270-278
[9]  
Dagher M, 2014, IMPLANT DENT
[10]   Proposal for an ultrasonic tool to monitor the osseointegration of dental implants [J].
de Almeida, Marina Storani ;
Maciel, Carlos Dias ;
Pereira, Jose Carlos .
SENSORS, 2007, 7 (07) :1224-1237