A clinical study of space closure with nickel-titanium closed coil springs and an elastic module

被引:54
作者
Samuels, RHA
Rudge, SJ
Mair, LH
机构
[1] Glenfield Gen Hosp, Dept Orthodont & Restorat Dent, Leicester LE3 9QP, Leics, England
[2] Univ Liverpool, Dent Hosp, Dept Orthodont, Liverpool L69 3BX, Merseyside, England
[3] Univ Liverpool, Dent Hosp, Dept Restorat Dent, Liverpool L69 3BX, Merseyside, England
关键词
D O I
10.1016/S0889-5406(98)70241-0
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
A previous study has shown that a 150-gram nickel-titanium closed coil spring (Sentalloy, GAC International Inc.) closed spaces more quickly and more consistently than an elastic module (Alastik, Unitec/3M). This study used the same friction sensitive sliding mechanics of pitting the six anterior teeth against the second bicuspid and first molars, to examine the rate of space closure of 100-gram and 200-gram nickel-titanium closed coil springs. The results for the three springs and elastic module were compared. The nickel-titanium closed coil springs produced a more consistent space closure than the elastic module. The 150- and 200-gram springs produced a faster rate of space closure than the elastic module or the 100-gram spring. No significant difference was noted between the rates of closure for the 150- and the 200-gram springs.
引用
收藏
页码:73 / 79
页数:7
相关论文
共 19 条
[1]  
ANDREASEN G, 1967, ANGLE ORTHOD, V37, P9
[2]   A CLINICAL-EVALUATION OF THE DIFFERENTIAL FORCE CONCEPT AS APPLIED TO THE EDGEWISE BRACKET [J].
ANDREASEN, GF ;
ZWANZIGER, D .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 1980, 78 (01) :25-40
[3]  
[Anonymous], J DENT RES
[4]  
Bennett J C, 1990, J Clin Orthod, V24, P251
[5]  
BOESTER CH, 1974, ANGLE ORTHOD, V44, P113
[6]   Canine retraction with rare earth magnets: An investigation into the validity of the constant force hypothesis [J].
Daskalogiannakis, J ;
McLachlan, KR .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 1996, 109 (05) :489-495
[7]   TRANSLATION OF PREMOLARS IN DOG BY CONTROLLING MOMENT-TO-FORCE RATIO ON CROWN [J].
FORTIN, JM .
AMERICAN JOURNAL OF ORTHODONTICS, 1971, 59 (06) :541-&
[8]   ON FORCE AND TOOTH MOVEMENT [J].
HIXON, EH ;
AOSEN, TO ;
ARANGO, J ;
CLARK, RA ;
KLOSTERMAN, R ;
MILLER, SS ;
ODOM, WM .
AMERICAN JOURNAL OF ORTHODONTICS, 1970, 57 (05) :476-+
[9]   OPTIMAL FORCE DIFFERENTIAL FORCE AND ANCHORAGE [J].
HIXON, EH ;
ATIKIAN, H ;
CALLOW, GE ;
MCDONALD, HW ;
TACY, RJ .
AMERICAN JOURNAL OF ORTHODONTICS, 1969, 55 (05) :437-+