Fibular strut allograft influences reduction and outcomes after locking plate fixation of comminuted proximal humeral fractures in elderly patients: a retrospective study

被引:25
作者
Cui, Xueliang [1 ,2 ,3 ]
Chen, Hui [1 ,2 ,3 ]
Ma, Binbin [1 ,2 ,3 ]
Fan, Wenbin [1 ,2 ,3 ]
Li, He [1 ,2 ,3 ]
机构
[1] Southeast Univ, Zhongda Hosp, Dept Orthopaed, 87 Ding Jia Qiao, Nanjing 210009, Jiangsu, Peoples R China
[2] Southeast Univ, Zhongda Hosp, Trauma Ctr, 87 Ding Jia Qiao, Nanjing 210009, Jiangsu, Peoples R China
[3] Southeast Univ, OTI, Nanjing 210009, Jiangsu, Peoples R China
关键词
Proximal humeral fracture; Fibular allograft; Locking plate; Elderly patients; AUGMENTATION; EPIDEMIOLOGY; FAILURE; SUPPORT;
D O I
10.1186/s12891-019-2907-3
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Proximal humeral fractures (PHFs) are the third most commonly occurring fractures in elderly patients. Most of these fractures can be treated with conservative methods, but the optimal surgical treatment strategy for unstable fractures in elderly patients remains controversial. This study aimed to compare the radiological and clinical outcomes between locking compression plate (LCP) fixation and LCP fixation with fibular allograft implantation for the treatment of comminuted PHFs. Methods: We retrospectively reviewed 60 patients (mean age, 72.75 years) with closed 3- or 4-part fractures, and a minimum of 2 years of follow-up. Fracture reduction was quantitatively determined by humeral head height (HHH) and neck-shaft angle (NSA). The clinical outcome was evaluated by Constant-Murley score (CMS) and American Shoulder and Elbow Surgeons (ASES) score. Result: The average radiological changes were higher in the LCP group than in the locking plate with fibular allograft group (HHH of 4.16 mm vs 1.18 mm [p < 0.001] and NSA of 9.94 degrees versus 3.12 degrees [p < 0.001]). The final average outcome scores were lower in the LCP group than in the FA group (CMS of 73.00 vs 78.96 [p = 0.024] and ASES score of 72.80 vs 78.64 [p = 0.022]). The FA group showed better forward elevation (p = 0.010) and abduction (p = 0.002); however, no significant differences were observed for shoulder external rotation or internal rotation. The number of complications was higher in the LCP group (28.57%) than in the FA group (1.2%) (p < 0.001). Conclusion: For comminuted PHFs in elderly patients, LCP fixation combined with a fibular allograft is reasonable option to ensure satisfactory radiological and clinical outcomes.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Open Reduction and Internal Fixation of Proximal Humeral Fractures with Use of the Locking Proximal Humerus Plate Results of a Prospective, Multicenter, Observational Study
    Suedkamp, N.
    Bayer, J.
    Hepp, P.
    Voigt, C.
    Oestern, H.
    Kaeaeb, M.
    Luo, C.
    Plecko, M.
    Wendt, K.
    Koestler, W.
    Konrad, G.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2009, 91A (06) : 1320 - 1328
  • [32] A Biomechanical Study of Tuberosity-Based Locked Plate Fixation Compared with Standard Proximal Humeral Locking Plate Fixation for 3-Part Proximal Humeral Fractures
    Walker, Robert
    Castaneda, Paulo
    Putnam, Jill G.
    Schemitsch, Emil H.
    McKee, Michael D.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2020, 34 (07) : E233 - E238
  • [33] Anterolateral acromial approach in locking plate fixation of proximal humerus fractures in elderly patients
    Cai, Jun-Feng
    Yuan, Feng
    Ma, Min
    Zhou, Wei
    Luo, Shu-Lin
    Yin, Feng
    ACTA ORTHOPAEDICA BELGICA, 2013, 79 (05): : 502 - 508
  • [34] Complications and Long-Term Outcomes of Open Reduction and Plate Fixation of Proximal Humeral Fractures
    Robinson, C. Michael
    Stirling, Paul H. C.
    Goudie, Ewan B.
    MacDonald, Deborah J.
    Strelzow, Jason A.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2019, 101 (23) : 2129 - 2139
  • [35] Valgising angular stable plate fixation in the treatment of multifragmentary proximal humeral fractures in elderly patients
    Máté Burkus
    A. Bruch
    E. M. Bergmann
    M. Karahodzic-Franjic
    M. Zdichavsky
    Archives of Orthopaedic and Trauma Surgery, 2024, 144 : 1637 - 1645
  • [36] Metallosis after using distal fibular locking plate for lateral malleolar fractures: a retrospective study
    Park, Sung Jun
    Bae, Gi Cheol
    Kwon, Dae Gyu
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2022, 142 (09) : 2157 - 2163
  • [37] Metallosis after using distal fibular locking plate for lateral malleolar fractures: a retrospective study
    Sung Jun Park
    Gi Cheol Bae
    Dae Gyu Kwon
    Archives of Orthopaedic and Trauma Surgery, 2022, 142 : 2157 - 2163
  • [38] Improved outcomes for proximal humerus fracture open reduction internal fixation augmented with a fibular allograft in elderly patients: a systematic review and meta-analysis
    Dasari, Suhas P.
    Kerzner, Benjamin
    Fortier, Luc M.
    Rea, Parker M.
    Bodendorfer, Blake M.
    Chahla, Jorge
    Garrigues, Grant E.
    Verma, Nikhil N.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2022, 31 (04) : 884 - 894
  • [39] Complications After Volar Locking Plate Fixation of Distal Radius Fractures: A Retrospective Study of 822 Patients
    Perregaard, Soren
    Jorgensen, Rasmus Wejnold
    Landgren, Marcus
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2024, 49 (08): : 745 - 750
  • [40] Comparison of the Effects of Proximal Humeral Internal Locking System (PHILOS) Alone and PHILOS Combined with Fibular Allograft in the Treatment of Neer Three- or Four-part Proximal Humerus Fractures in the Elderly
    Zhao, Lei
    Qi, Yi-min
    Yang, Lei
    Wang, Gang-rui
    Zheng, Sheng-nai
    Wang, Qiang
    Liang, Bin
    Jiang, Chun-zhi
    ORTHOPAEDIC SURGERY, 2019, 11 (06) : 1003 - 1012