Concentrated heparin lock is associated with major bleeding complications after tunneled hemodialysis catheter placement

被引:77
作者
Yevzlin, Alexander S.
Sanchez, Robert J.
Hiatt, Jeanne G.
Washington, Marilyn H.
Wakeen, Maureen
Hofmann, R. Michael
Beckert, Yolanda T.
机构
[1] Univ Wisconsin, Sch Med & Publ Hlth, Madison, WI 53713 USA
[2] Univ Wisconsin Hosp, Madison, WI USA
[3] Univ Wisconsin, Sch Pharm Social & Adm Sci, Madison, WI USA
关键词
D O I
10.1111/j.1525-139X.2007.00294.x
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Vascular access complications, including thrombosis, are associated with significant patient morbidity and mortality. Currently, up to 60% of new patients and 30% of prevalent patients are using a catheter for dialysis. To prevent interdialytic catheter thrombosis, these devices are routinely locked with concentrated heparin solutions. Several recent studies have elucidated the potential for abnormal coagulation markers (aPTT) that may arise from this practice. This abnormal elevation in aPTT may be explained by significant early and late leakage from the catheter that occurs after performing a catheter lock. To date no study has evaluated the impact of this practice, or the elevation in aPTT that may result from it, on bleeding complication rates. We conducted a retrospective analysis comparing bleeding rates in subjects who received concentrated heparin catheter lock (5000 u/cc) [group 1, = 52] to those who received citrate or dilute heparin catheter lock (1000 u/cc) [group 2, n = 91] immediately after tunneled hemodialysis catheter insertion. Baseline characteristics did not differ between the groups except for the preprocedure INR, which was higher in the postpolicy group compared with the prepolicy group (1.29 vs. 1.21, p = 0.04). Results from logistic regression analyses revealed that the likelihood of a composite bleeding event in group 1 was 11.9 times that of a composite bleeding event in group 2, p = 0.04. Concentrated heparin (5000 u/ml) is associated with increased major bleeding complications posttunneled catheter placement compared with low-dose heparin (1000 u/ml) or citrate catheter lock solution, p = 0.02. Given the findings of this study, a randomized controlled trial comparing the safety and efficacy of common anticoagulation lock solutions is warranted.
引用
收藏
页码:351 / 354
页数:4
相关论文
共 10 条
[1]  
*BARD ACC SYST INC, 2005, HEM TUNN HEM CATH
[2]   Antithrombotic measures for indwelling intravenous haemodialysis catheters - Columbus' egg yet to be found [J].
Barendregt, JNM ;
Tordoir, JHM ;
Leunissen, KML .
NEPHROLOGY DIALYSIS TRANSPLANTATION, 1999, 14 (08) :1834-1835
[3]  
DESWART CAM, 1982, BLOOD, V60, P1251
[4]   Type of vascular access and mortality in US hemodialysis patients [J].
Dhingra, RK ;
Young, EW ;
Hulbert-Shearon, TE ;
Leavey, SF ;
Port, FK .
KIDNEY INTERNATIONAL, 2001, 60 (04) :1443-1451
[5]   Risk of heparin lock-related bleeding when using indwelling venous catheter in haemodialysis [J].
Karaaslan, H ;
Peyronnet, P ;
Benevent, D ;
Lagarde, C ;
Rince, M ;
Leroux-Robert, C .
NEPHROLOGY DIALYSIS TRANSPLANTATION, 2001, 16 (10) :2072-2074
[6]  
Mauro M A, 1993, J Vasc Interv Radiol, V4, P127, DOI 10.1016/S1051-0443(93)71835-7
[7]  
*NKFDOQI CLIN PRAC, 1997, AM J KIDNEY DIS S, V30, pS150
[8]  
*US REN DAT SYST, 2005, USRDS 1999 ANN DAT R
[9]  
*VASC ACC WORK GRO, 2003, AM J KIDNEY DIS, V48, pS248
[10]   The 'heparin lock': cause for iatrogenic coagulopathy [J].
Vorweg, M ;
Monaca, E ;
Doehn, M ;
Wappler, E .
EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2006, 23 (01) :50-53