Effect of Tip Clearance on Rotating Stall in a Mixed-Flow Pump

被引:25
作者
Li, Wei [1 ,2 ]
Ji, Leilei [3 ]
Li, Enda [3 ]
Zhou, Ling [4 ]
Agarwal, Ramesh K. [5 ]
机构
[1] Jiangsu Univ, Natl Res Ctr Pumps, ASME, Zhenjiang 212013, Jiangsu, Peoples R China
[2] Jiangsu Univ, Inst Fluid Engn Equipment Technol, Zhenjiang 212009, Jiangsu, Peoples R China
[3] Jiangsu Univ, Natl Res Ctr Pumps, Zhenjiang 212013, Jiangsu, Peoples R China
[4] Nantong Univ, Coll Mech Engn, Nantong 226019, Peoples R China
[5] Washington Univ, Dept Mech Engn & Mat Sci, St Louis, MO 63130 USA
来源
JOURNAL OF TURBOMACHINERY-TRANSACTIONS OF THE ASME | 2021年 / 143卷 / 09期
基金
中国国家自然科学基金;
关键词
mixed-flow pump; tip clearance; numerical simulation; energy performance; internal flow fields; rotating stall; centrifugal compressors and pumps; compressor stall; surge; and operability; computational fluid dynamics (CFD); fluid dynamics and heat transfer phenomena in compressor and turbine components of gas turbine engines; LEAKAGE FLOW; BLADE TIP; PERFORMANCE; MECHANISM; NOISE; ANGLE; FIELD; FANS;
D O I
10.1115/1.4050625
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
The non-uniform disturbance in the circumferential direction is the essential cause of the occurrence of rotating stall in a turbomachinery. In order to study the effect of tip clearance leakage flow on rotating stall, the mixed-flow pump models with different tip clearances were numerically calculated, and then the energy performance curves and internal flow structures were obtained and compared. The results show that the pump efficiency and the internal flow field of the numerical calculation are in good agreement with the experimental results. A saddle region appeared in the energy performance curves of the three tip clearances, and with the decrease of clearance, the head and efficiency of the mixed-flow pump increased to varying degrees, but the critical stall point shifted to the large flowrate, and the stable operating range of the mixed-flow pump decreased, which indicating that the mixed-flow pumps were easier to stall under small tip clearance. Under the deep stall condition, the influence of the leakage flow on the end wall area increases gradually with the decrease of clearance. Under the small clearance, the leakage flow flows away from the suction surface for a certain distance to form a number of tip leakage vortex strips with the mainstream action, overflows the leading edge of the next blade, and then flows downstream into different flow passages, aggravating backflow and secondary flow separation at the blade inlet, which seriously damaged the spatial structure of the inlet flow. This resulted in the earlier occurrence of stall. With the increase of tip clearance, the tip leakage vortex develops along the radial direction to the middle of the flow channel and serious flow separation phenomenon occurs in the downstream channel, which induces the deep stall. Under the 0.8 mm tip clearance, the whole impeller outlet passage is almost blocked by the backflow of the guide vane inlet, and a deep stall was induced.
引用
收藏
页数:11
相关论文
共 33 条
  • [1] Experimental study of the effect of blade tip clearance and blade angle error on the performance of mixed-flow pump
    Bing Hao
    Cao ShuLiang
    He ChengLian
    Lu Li
    [J]. SCIENCE CHINA-TECHNOLOGICAL SCIENCES, 2013, 56 (02) : 293 - 298
  • [2] Chang S., 2012, J DRAIN IRRIG MACH E, V30, P646
  • [3] Tip clearance noise of axial flow fans operating at design and off-design condition
    Fukano, T
    Jang, CM
    [J]. JOURNAL OF SOUND AND VIBRATION, 2004, 275 (3-5) : 1027 - 1050
  • [4] THE EFFECT OF TIP LEAKAGE FLOW ON PART-LOAD PERFORMANCE OF A MIXED-FLOW PUMP IMPELLER
    GOTO, A
    [J]. JOURNAL OF TURBOMACHINERY-TRANSACTIONS OF THE ASME, 1992, 114 (02): : 383 - 391
  • [5] The Role of Tip Leakage Flow in Spike-Type Rotating Stall Inception
    Hewkin-Smith, M.
    Pullan, G.
    Grimshaw, S. D.
    Greitzer, E. M.
    Spakovszky, Z. S.
    [J]. JOURNAL OF TURBOMACHINERY-TRANSACTIONS OF THE ASME, 2019, 141 (06):
  • [6] Diagnosis of internal energy characteristics of mixed-flow pump within stall region based on entropy production analysis model
    Ji, Leilei
    Li, Wei
    Shi, Weidong
    Tian, Fei
    Agarwal, Ramesh
    [J]. INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2020, 117 (117)
  • [7] Energy characteristics of mixed-flow pump under different tip clearances based on entropy production analysis
    Ji, Leilei
    Li, Wei
    Shi, Weidong
    Chang, Hao
    Yang, Zhenyu
    [J]. ENERGY, 2020, 199
  • [8] Influence of tip leakage flow and inlet distortion flow on a mixed-flow pump with different tip clearances within the stall condition
    Ji, Leilei
    Li, Wei
    Shi, Weidong
    [J]. PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART A-JOURNAL OF POWER AND ENERGY, 2020, 234 (04) : 433 - 453
  • [9] Treatment and optimization of casing and blade tip for aerodynamic control of tip leakage flow in a turbine cascade
    Jiang Shuai
    Chen Fu
    Yu Jianyang
    Chen Shaowen
    Song Yanping
    [J]. AEROSPACE SCIENCE AND TECHNOLOGY, 2019, 86 : 704 - 713
  • [10] Kim D.J., P ASME 2013 FLUIDS E