Prefabricated connection for steel beam and concrete-filled steel tube column

被引:32
作者
Ding, Chenting [1 ]
Pan, Xuebei [2 ]
Bai, Yu [1 ]
Shi, Gang [3 ]
机构
[1] Monash Univ, Dept Civil Engn, Clayton, Vic 3800, Australia
[2] Hefei Univ Technol, Sch Civil Engn, Hefei 230009, Anhui, Peoples R China
[3] Tsinghua Univ, Key Lab Civil Engn Safety & Durabil, China Educ Minist, Dept Civil Engn, Beijing 100084, Peoples R China
基金
澳大利亚研究理事会;
关键词
Concrete-filled steel tube; Steel structures; Beam-column connection; Prefabrication; Bolted connection; Moment-rotation behaviour; END-PLATE JOINTS; EXPERIMENTAL BEHAVIOR; CFT COLUMN; SYSTEM;
D O I
10.1016/j.jcsr.2019.105751
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
A new type of connection system with steel beam and concrete-filled steel tube (CFST) column is proposed in this paper. This type of connection system uses internal stiffeners and high-strength threaded steel rods to connect the steel beams in two directions with the assistance of side plates pre-welded on the column, intending to serve for high-rise buildings where moderate or high ductility is required, and is geometrically possible to be covered within the wall or floor space therefore offering architectural pleasing. The force transfer mechanisms of the connection are important for the corresponding load-carrying capacities and may be different in the two beam directions. In order to investigate the mechanical properties of the connection system, four different specimens, including interior and exterior connections with corresponding columns and beams in two directions, were made and examined under monotonic loadings, further with comparison to FE modelling results. The results of experimental and numerical investigations indicate the proposed connection system offers satisfactory stiffness and load-carrying capacities. Force transfer mechanisms are discussed with assistance from stress and strain responses identified from validated FE modelling in details. Design considerations are further highlighted for implementation in practice. (C) 2019 Elsevier Ltd. All rights reserved.
引用
收藏
页数:13
相关论文
共 36 条
[1]   Analytical behavior of connections to concrete-filled steel tubes [J].
Alostaz, YM ;
Schneider, SP .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 1996, 40 (02) :95-127
[2]  
[Anonymous], 2009, 8981 ISO BSI
[3]  
Australian Standard, 1991, AS 1391
[4]   New Connection System for Confined Concrete Columns and Beams. II: Theoretical Modeling [J].
Bai, Yu ;
Nie, Jianguo ;
Cai, C. S. .
JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 2008, 134 (12) :1800-1809
[5]  
CEN, 2005, EUR 3 DES STEEL ST 1
[6]   Seismic performance of steel beams to concrete-filled steel tubular column connections [J].
Cheng, CT ;
Chung, LL .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2003, 59 (03) :405-426
[7]  
Clark P., 1997, Protocol for fabrication, inspection, testing and documentation of beam-column connection and other experimental specimens
[8]   Stiffener configurations of beam to concrete-filled tube column connections [J].
Dessouki, Abdelrahim K. ;
Yousef, Ahmed H. ;
Fawzy, Mona M. .
STEEL AND COMPOSITE STRUCTURES, 2014, 17 (01) :83-103
[9]   Elasto-plastic analysis of circular concrete-filled steel tube stub columns [J].
Ding, Fa-xing ;
Yu, Zhi-wu ;
Bai, Yu ;
Gong, Yong-zhi .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2011, 67 (10) :1567-1577
[10]   Load-deformation characteristics and performance of internal diaphragm connections to box columns [J].
Doung, P. ;