Comparison of Real-Time Two-Dimensional and Three-Dimensional Contrast-Enhanced Ultrasound to Quantify Flow in an In Vitro Model: A Feasibility Study

被引:4
|
作者
Ruan, Si-Min [1 ]
Zheng, Qiao [2 ]
Wang, Zhu [1 ]
Hu, Hang-Tong [1 ]
Chen, Li-Da [1 ]
Guo, Huan-Ling [1 ]
Xie, Xiao-Yan [1 ]
Lu, Ming-De [1 ,3 ]
Li, Wei [1 ]
Wang, Wei [1 ]
机构
[1] Sun Yat Sen Univ, Inst Diagnost & Intervent Ultrasound, Dept Med Ultrason, Ultrason Artificial Intelligence X Lab,Affiliated, Guangzhou, Guangdong, Peoples R China
[2] Sun Yat Sen Univ, Fetal Med Ctr, Dept Med Ultrason, Affiliated Hosp 1, Guangzhou, Guangdong, Peoples R China
[3] Sun Yat Sen Univ, Dept Hepatobiliary Surg, Affiliated Hosp 1, Guangzhou, Guangdong, Peoples R China
来源
MEDICAL SCIENCE MONITOR | 2019年 / 25卷
关键词
Contrast Media; Imaging; Three-Dimensional; In Vitro; Ultrasonography; FOCAL LIVER-LESIONS; QUANTIFICATION; SUPERIOR; US;
D O I
10.12659/MSM.919160
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Background: This feasibility study aimed to compare real-time two-dimensional contrast-enhanced ultrasound (2D-CEUS) and three-dimensional contrast-enhanced ultrasound (3D-CEUS) to quantify flow in an in vitro model. Material/Methods: Five polyvinyl chloride (PVC) tubes were used for the perfusion models and used SonoVue ultrasound contrast agent with a perfusion volume ratio of 1: 2: 4: 8: 16. The contrast was injected at a constant speed to compare the raw quantitative data of 2D-CEUS and 3D-CEUS at angles of 0 degrees, 45 degrees, and 90 degrees. The coefficient of variation (CV) of the peak intensity (PI) in the model were compared and the correlations between weighted PI and perfusion volume were analyzed. Results: In the three angles used, real-time 3D-CEUS resulted in a more comprehensive view of the spatial relationships in the perfusion model. Using real-time 2D-CEUS, the mean CV was 0.92 +/- 0.36, and the mean CV in the real-time 3D-CEUS model was significantly less at 0.48 +/- 0.32 (p<0.001). Quantitative 3D-CEUS parameters showed a good correlation with those of 2D-CEUS with an r-value of 0.93 (p=0.02). The r-value of weighted PI and the perfusion ratio using 2D-CEUS was 0.66 (p=0.23) compared with values in 3D-CEUS of 0.84 (p=0.08). Conclusions: The combination of real-time 3D-CEUS and quantitative analysis identified the spatial distribution of the changes in angle in the model, which was less influenced by sectional planes, and was more representative of the perfusion volume when compared with 2D-CEUS. Quantitative real-time 3D-CEUS requires in vivo studies to evaluate the potential role in the clinical evaluation of vascular perfusion of malignant tumors.
引用
收藏
页码:10029 / 10035
页数:7
相关论文
共 50 条
  • [31] Off-site evaluation of three-dimensional ultrasound for the diagnosis of thyroid nodules: comparison with two-dimensional ultrasound
    Kim, Soo Chin
    Kim, Ji-hoon
    Choi, Seung Hong
    Yun, Tae Jin
    Wi, Jae Yeon
    Kim, Sun Ah
    Sun, Hye Young
    Ryoo, Inseon
    Park, Sun-Won
    Sohn, Chul-Ho
    EUROPEAN RADIOLOGY, 2016, 26 (10) : 3353 - 3360
  • [32] Clinical Implications of Three-Dimensional Real-Time Color Doppler Transthoracic Echocardiography in Quantifying Mitral Regurgitation: A Comparison with Conventional Two-Dimensional Methods
    Heo, Ran
    Son, Jang-Won
    Hartaigh, Briain O.
    Chang, Hyuk-Jae
    Kim, Young-Jin
    Datta, Saurabh
    Cho, In-Jeong
    Shim, Chi Young
    Hong, Geu-Ru
    Ha, Jong-Won
    Chung, Namsik
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2017, 30 (04) : 393 - U158
  • [33] Feasibility study of real-time three-/four-dimensional ultrasound for epidural catheter insertion
    Belavy, D.
    Ruitenberg, M. J.
    Brijball, R. B.
    BRITISH JOURNAL OF ANAESTHESIA, 2011, 107 (03) : 438 - 445
  • [34] Analysis of Left Ventricular Volumes and Function: A Multicenter Comparison of Cardiac Magnetic Resonance Imaging, Cine Ventriculography, and Unenhanced and Contrast-Enhanced Two-Dimensional and Three-Dimensional Echocardiography
    Hoffmann, Rainer
    Barletta, Giuseppe
    von Bardeleben, Stephan
    Vanoverschelde, Jean Louis
    Kasprzak, Jaroslaw
    Greis, Christian
    Becher, Harald
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2014, 27 (03) : 292 - 301
  • [35] Quantitative assessment of carotid artery atherosclerosis by three-dimensional magnetic resonance and two-dimensional ultrasound imaging: a comparison study
    Qiao, Huiyu
    Cai, Ying
    Huang, Manwei
    Liu, Yang
    Qiang, Zhang
    Huang, Lingyun
    Chen, Huijun
    Yuan, Chun
    Zhao, Xihai
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2020, 10 (05) : 1021 - 1032
  • [36] Real-time measurement of renal blood flow in healthy subjects using contrast-enhanced ultrasound
    Kalantarinia, Kambiz
    Belcik, J. Todd
    Patrie, James T.
    Wei, Kevin
    AMERICAN JOURNAL OF PHYSIOLOGY-RENAL PHYSIOLOGY, 2009, 297 (04) : F1129 - F1134
  • [37] Focal Liver Lesions: Real-time 3-Dimensional Contrast-Enhanced Ultrasonography Compared With 2-Dimensional Contrast-Enhanced Ultrasonography and Magnetic Resonance Imaging
    Lee, Jung-chieh
    Yan, Kun
    Lee, San-kan
    Yang, Wei
    Chen, Min-hua
    JOURNAL OF ULTRASOUND IN MEDICINE, 2017, 36 (10) : 2015 - 2026
  • [38] Focal liver lesions: interobserver and intraobserver agreement of three-dimensional contrast-enhanced ultrasound-assisted volume measurements
    Bartolotta, Tommaso Vincenzo
    Pinto, Antonio Sidoti
    Cannella, Roberto
    Porrello, Giorgia
    Taravella, Rossana
    Randazzo, Angelo
    Taibbi, Adele
    ULTRASONOGRAPHY, 2021, 40 (03) : 333 - 341
  • [39] Three-dimensional contrast-enhanced ultrasound improves endoleak detection and classification after endovascular aneurysm repair
    Lowe, Christopher
    Abbas, Abeera
    Rogers, Steven
    Smith, Lee
    Ghosh, Jonathan
    McCollum, Charles
    JOURNAL OF VASCULAR SURGERY, 2017, 65 (05) : 1453 - 1459
  • [40] Contrast-enhanced two- and three-dimensional sonography for evaluation of intra-abdominal hemorrhage
    Liu, JB
    Merton, DA
    Goldberg, BB
    Rawool, NM
    Shi, WT
    Forsberg, F
    JOURNAL OF ULTRASOUND IN MEDICINE, 2002, 21 (02) : 161 - 169