Comparison of Real-Time Two-Dimensional and Three-Dimensional Contrast-Enhanced Ultrasound to Quantify Flow in an In Vitro Model: A Feasibility Study

被引:4
|
作者
Ruan, Si-Min [1 ]
Zheng, Qiao [2 ]
Wang, Zhu [1 ]
Hu, Hang-Tong [1 ]
Chen, Li-Da [1 ]
Guo, Huan-Ling [1 ]
Xie, Xiao-Yan [1 ]
Lu, Ming-De [1 ,3 ]
Li, Wei [1 ]
Wang, Wei [1 ]
机构
[1] Sun Yat Sen Univ, Inst Diagnost & Intervent Ultrasound, Dept Med Ultrason, Ultrason Artificial Intelligence X Lab,Affiliated, Guangzhou, Guangdong, Peoples R China
[2] Sun Yat Sen Univ, Fetal Med Ctr, Dept Med Ultrason, Affiliated Hosp 1, Guangzhou, Guangdong, Peoples R China
[3] Sun Yat Sen Univ, Dept Hepatobiliary Surg, Affiliated Hosp 1, Guangzhou, Guangdong, Peoples R China
来源
MEDICAL SCIENCE MONITOR | 2019年 / 25卷
关键词
Contrast Media; Imaging; Three-Dimensional; In Vitro; Ultrasonography; FOCAL LIVER-LESIONS; QUANTIFICATION; SUPERIOR; US;
D O I
10.12659/MSM.919160
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Background: This feasibility study aimed to compare real-time two-dimensional contrast-enhanced ultrasound (2D-CEUS) and three-dimensional contrast-enhanced ultrasound (3D-CEUS) to quantify flow in an in vitro model. Material/Methods: Five polyvinyl chloride (PVC) tubes were used for the perfusion models and used SonoVue ultrasound contrast agent with a perfusion volume ratio of 1: 2: 4: 8: 16. The contrast was injected at a constant speed to compare the raw quantitative data of 2D-CEUS and 3D-CEUS at angles of 0 degrees, 45 degrees, and 90 degrees. The coefficient of variation (CV) of the peak intensity (PI) in the model were compared and the correlations between weighted PI and perfusion volume were analyzed. Results: In the three angles used, real-time 3D-CEUS resulted in a more comprehensive view of the spatial relationships in the perfusion model. Using real-time 2D-CEUS, the mean CV was 0.92 +/- 0.36, and the mean CV in the real-time 3D-CEUS model was significantly less at 0.48 +/- 0.32 (p<0.001). Quantitative 3D-CEUS parameters showed a good correlation with those of 2D-CEUS with an r-value of 0.93 (p=0.02). The r-value of weighted PI and the perfusion ratio using 2D-CEUS was 0.66 (p=0.23) compared with values in 3D-CEUS of 0.84 (p=0.08). Conclusions: The combination of real-time 3D-CEUS and quantitative analysis identified the spatial distribution of the changes in angle in the model, which was less influenced by sectional planes, and was more representative of the perfusion volume when compared with 2D-CEUS. Quantitative real-time 3D-CEUS requires in vivo studies to evaluate the potential role in the clinical evaluation of vascular perfusion of malignant tumors.
引用
收藏
页码:10029 / 10035
页数:7
相关论文
共 50 条
  • [21] Clinical utility of contrast-enhanced three-dimensional ultrasound imaging with Sonazoid: Findings on hepatocellular carcinoma lesions
    Luo, Wen
    Numata, Kazushi
    Morimoto, Manabu
    Nozaki, Akito
    Nagano, Yasuhiko
    Sugimori, Kazuya
    Zhou, Xiaodong
    Tanaka, Katsuaki
    EUROPEAN JOURNAL OF RADIOLOGY, 2009, 72 (03) : 425 - 431
  • [22] Characteristics of benign and malignant tumor shown on three-dimensional ultrasound and contrast-enhanced ultrasound and their diagnostic efficacy
    Zhang, Mei
    Li, Juan
    Zhang, Hong
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2018, 11 (03): : 2559 - 2565
  • [23] Real-time three-dimensional ultrasound methods for shape analysis and visualization
    Stetten, G
    Tamburo, R
    METHODS, 2001, 25 (02) : 221 - 230
  • [24] Quantitative Comparison of Two-Dimensional and Three-Dimensional Discrete-Element Simulations of Nominally Two-Dimensional Shear Flow
    Fleischmann, J. A.
    Plesha, M. E.
    Drugan, W. J.
    INTERNATIONAL JOURNAL OF GEOMECHANICS, 2013, 13 (03) : 205 - 212
  • [25] Immediate evaluation and guidance of liver cancer thermal ablation by three-dimensional ultrasound/contrast-enhanced ultrasound fusion imaging
    Xu, Er-Jiao
    Lv, Shu-Min
    Li, Kai
    Long, Ying-Lin
    Zeng, Qing-Jing
    Su, Zhong-Zhen
    Zheng, Rong-Qin
    INTERNATIONAL JOURNAL OF HYPERTHERMIA, 2018, 34 (06) : 870 - 876
  • [26] Real-time three-dimensional echocardiography for left atrial volume assessment in Thoroughbred racehorses: Observer variability and comparison with two-dimensional echocardiography
    Worsman, Francesca C. F.
    Miller, Zack J.
    Shaw, Darren J.
    Blissitt, Karen J.
    Keen, John A.
    EQUINE VETERINARY JOURNAL, 2022, 54 (01) : 176 - 190
  • [27] Three-dimensional contrast-enhanced MR angiography with real-time fluoroscopic triggering: Design specifications and technical reliability in 330 patient studies
    Riederer, SJ
    Bernstein, MA
    Breen, JF
    Busse, RF
    Ehman, RL
    Fain, SB
    Hulshizer, TC
    Huston, J
    King, BF
    Kruger, DG
    Rossman, PJ
    Shah, S
    RADIOLOGY, 2000, 215 (02) : 584 - 593
  • [28] Quantitative Three-Dimensional Dynamic Contrast-Enhanced Ultrasound Imaging: First-In-Human Pilot Study in Patients with Liver Metastases
    El Kaffas, Ahmed
    Sigrist, Rosa Maria Silveira
    Fisher, George
    Bachawal, Sunitha
    Liau, Joy
    Wang, Huaijun
    Karanany, Alexander
    Durot, Isabelle
    Rosenberg, Jarrett
    Hristov, Dimitre
    Willmann, Jurgen K.
    THERANOSTICS, 2017, 7 (15): : 3745 - 3758
  • [29] Comparing the feasibility and accuracy of three-dimensional ultrasound to two-dimensional ultrasound and computed tomography angiography in the assessment of carotid atherosclerosis
    Song, Shinjeong
    Heo, Ran
    Lee, Sang-Eun
    Park, Jinki
    Lee, Jinyong
    Kim, Sujin
    Cho, In Jeong
    Chang, Hyuk-Jae
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2019, 36 (12): : 2241 - 2250
  • [30] Evaluation of left ventricular rotation by two-dimensional speckle tracking method and real-time three-dimensional echocardiography: Comparison with MRI tagging method
    Hayashi H.
    Izumi C.
    Takahashi S.
    Uchikoshi M.
    Yamazaki R.
    Asanuma T.
    Ishikura F.
    Beppu S.
    Nakatani S.
    Journal of Echocardiography, 2011, 9 (3) : 83 - 89