Simultaneous determination of catechol and hydroquinone based on poly (diallyldimethylammonium chloride) functionalized graphene-modified glassy carbon electrode

被引:91
|
作者
Wang, Letao [1 ]
Zhang, Yan [1 ]
Du, Yongling [1 ]
Lu, Daban [1 ]
Zhang, Yuzhen [1 ]
Wang, Chunming [1 ]
机构
[1] Lanzhou Univ, Dept Chem, Lanzhou 730000, Peoples R China
基金
中国国家自然科学基金;
关键词
Catechol; Hydroquinone; Graphene; PDDA; Simultaneous determination; DIHYDROXYBENZENE ISOMERS; PASTE ELECTRODE; IONIC LIQUID; ELECTROCHEMICAL BEHAVIORS; PHENOLIC-COMPOUNDS; COMPOSITE FILM; NANOTUBES; CHEMILUMINESCENCE; SYSTEM; CHROMATOGRAPHY;
D O I
10.1007/s10008-011-1526-1
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
Simultaneous determination of catechol (CC) and hydroquinone (HQ) were investigated by voltammetry based on glassy carbon electrode (GCE) modified by poly (diallyldimethylammonium chloride) (PDDA) functionalized graphene (PDDA-G). The modified electrode showed excellent sensitivity and selectivity properties for the two dihydroxybenzene isomers. In 0.1 mol/L phosphate buffer solution (PBS, pH 7.0), the oxidation peak potential difference between CC and HQ was 108 mV, and the peaks on the PDDA-G/GCE were three times as high as the ones on graphene-modified glass carbon electrode. Under optimized conditions, the PDDA-G/GCE showed wide linear behaviors in the range of 1 x 10(-6)-4 x 10(-4) mol/L for CC and 1 x 10(-6)-5 x 10(-4) mol/L for HQ, with the detection limits 2.0 x 10(-7) mol/L for CC and 2.5 x 10(-7) mol/L for HQ (S/N = 3) in mixture, respectively. Some kinetic parameters, such as the electron transfer number (n), charge transfer coefficient (alpha), and the apparent heterogeneous electron transfer rate constant (k (s)), were calculated. The proposed method was applied to simultaneous determine CC and HQ in real water samples of Yellow River with satisfactory results.
引用
收藏
页码:1323 / 1331
页数:9
相关论文
共 50 条
  • [1] Simultaneous determination of catechol and hydroquinone based on poly (diallyldimethylammonium chloride) functionalized graphene-modified glassy carbon electrode
    Letao Wang
    Yan Zhang
    Yongling Du
    Daban Lu
    Yuzhen Zhang
    Chunming Wang
    Journal of Solid State Electrochemistry, 2012, 16 : 1323 - 1331
  • [2] A voltammetric sensor based on graphene-modified electrode for simultaneous determination of catechol and hydroquinone
    Du, Haijun
    Ye, Jianshan
    Zhang, Jiaqi
    Huang, Xiaodan
    Yu, Chengzhong
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2011, 650 (02) : 209 - 213
  • [3] Simultaneous Determination of Hydroquinone, Catechol and Resorcinol Based on Graphene/Cobalt Hexacyanoferrate Modified Glassy Carbon Electrode
    Huang Kejing
    Yu Sheng
    Wang Lan
    Gan Tian
    Li Mei
    ACTA CHIMICA SINICA, 2012, 70 (06) : 735 - 740
  • [4] Simultaneous Detection of Hydroquinone and Catechol at a Three-Dimensional Graphene-Modified Glassy Carbon Electrode
    Wang, Yuting
    Chen, Xiangfei
    Huang, Dejuan
    Jin, Tianxiang
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2020, 15 (07): : 6620 - 6628
  • [5] Simultaneous determination of hydroquinone and catechol based on glassy carbon electrode modified with gold-graphene nanocomposite
    Ma, Xuemei
    Liu, Zhaona
    Qiu, Cuicui
    Chen, Ting
    Ma, Houyi
    MICROCHIMICA ACTA, 2013, 180 (5-6) : 461 - 468
  • [6] Multiwall carbon nanotubes-poly(diallyldimethylammonium chloride)-graphene hybrid composite film for simultaneous determination of catechol and hydroquinone
    Song, Daimin
    Xia, Jianfei
    Zhang, Feifei
    Bi, Sai
    Xiang, Wenjun
    Wang, Zonghua
    Xia, Lin
    Xia, Yanzhi
    Li, Yanhui
    Xia, Linhua
    SENSORS AND ACTUATORS B-CHEMICAL, 2015, 206 : 111 - 118
  • [7] Simultaneous electrochemical determination of catechol and hydroquinone based on graphene-TiO2 nanocomposite modified glassy carbon electrode
    Zhang, Yanli
    Xie, Jinling
    Xiao, Shixiu
    Yang, Zhongming
    Pang, Pengfei
    Gao, Yuntao
    SENSORS AND ACTUATORS B-CHEMICAL, 2014, 204 : 102 - 108
  • [8] Simultaneous determination of catechol and hydroquinone based on poly(sulfosalicylic acid)/functionalized graphene modified electrode
    Li, Cong
    Liu, Weilu
    Gu, Yue
    Hao, Shuming
    Yan, Xiaoyi
    Zhang, Zhiquan
    Yang, Ming
    JOURNAL OF APPLIED ELECTROCHEMISTRY, 2014, 44 (09) : 1059 - 1067
  • [9] Highly sensitive and simultaneous determination of hydroquinone and catechol at poly(thionine) modified glassy carbon electrode
    Ahammad, A. J. Saleh
    Rahman, Md Mahbubur
    Xu, Guang-Ri
    Kim, Sunghyun
    Lee, Jae-Joon
    ELECTROCHIMICA ACTA, 2011, 56 (14) : 5266 - 5271
  • [10] Simultaneous determination of hydroquinone and catechol at PASA/MWNTs composite film modified glassy carbon electrode
    Zhao, Dong-Ming
    Zhang, Xiu-Hua
    Feng, Li-Jun
    Jia, Li
    Wang, Sheng-Fu
    COLLOIDS AND SURFACES B-BIOINTERFACES, 2009, 74 (01) : 317 - 321