Accuracy and stability of deep inspiration breath hold in gated breast radiotherapy - A comparison of two tracking and guidance systems

被引:17
作者
Kalet, Alan M. [1 ,2 ]
Cao, Ning [1 ,2 ]
Smith, Wade P. [1 ]
Young, Lori [1 ,2 ]
Wootton, Landon [1 ,2 ]
Stewart, Rob D. [1 ]
Fang, L. Christine [1 ,2 ]
Kim, Janice [1 ,2 ]
Horton, Tony [2 ]
Meyer, Juergen [1 ,2 ]
机构
[1] Univ Washington, Dept Radiat Oncol, Seattle, WA 98195 USA
[2] Seattle Canc Care Alliance, Dept Radiat Oncol, Seattle, WA 98109 USA
来源
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS | 2019年 / 60卷
关键词
Biofeedback; Surface imaging; Motion management; SURFACE-IMAGING-SYSTEM; AUDIOVISUAL BIOFEEDBACK; CLINICAL-EVALUATION; RESPIRATORY MOTION; RADIATION-THERAPY; CANCER PATIENTS; HEART POSITION; SETUP ACCURACY; REPRODUCIBILITY; PATIENT;
D O I
10.1016/j.ejmp.2019.03.025
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To characterize reproducibility of patient breath-hold positioning and compare tracking system performance for Deep Inspiration Breath Hold (DIBH) gated left breast radiotherapy. Methods: 29 consecutive left breast DIBH patients (655 fractions) were treated under the guidance of Calypso surface beacons with audio-feedback and 35 consecutive patients (631 fractions) were treated using C-RAD Catalyst HD surface imaging with audiovisual feedback. The Calypso system tracks a centroid determined by two radio-frequency transponders, with a manually enforced institutional tolerance, while the surface image based CatalystHD system utilizes real-time biometric feedback to track a pre-selected point with an institutional tolerance enforced by the Elekta Response gating interface. DIBH motion data from Calypso was extracted to obtain the displacement of breath hold marker in ant/post direction from a set-zero reference point. Ant/post point displacement data from CatalystHD was interpreted by computing the difference between raw tracking points and the center of individual gating windows. Mean overall errors were compared using Welsh's unequal variance t-test. Wilcoxon rank sum test were used for statistical analysis with P < 0.05 considered significant. Results: Mean overall error for Calypso and CatalystHD were 0.33 +/- 1.17 mm and 0.22 +/- 0.43 mm, respectively, with t-test comparison P-value < 0.034. Absolute errors for Calypso and CatalystHD were 0.95 +/- 0.75 mm and 0.38 +/- 0.30 mm, respectively, with Wilcoxon rank sum test P-value <2 x 10(-16). Average standard deviation per fraction was found to be 0.74 +/- 0.44 mm for Calypso patients versus 0.54 +/- 0.22 mm for CatalystHD. Conclusion: Reduced error distribution widths in overall positioning, deviation of position, and per fraction deviation suggest that the use of functionalities available in CatalystHD such as audiovisual biofeedback and patient surface matching improves accuracy and stability during DIBH gated left breast radiotherapy.
引用
收藏
页码:174 / 181
页数:8
相关论文
共 47 条
  • [31] A phantom evaluation of Sentinel™, a commercial laser/camera surface imaging system for patient setup verification in radiotherapy
    Pallotta, Stefania
    Marrazzo, Livia
    Ceroti, Marco
    Silli, Pierfrancesco
    Bucciolini, Marta
    [J]. MEDICAL PHYSICS, 2012, 39 (02) : 706 - 712
  • [32] Quasi-breath-hold technique using personalized audio-visual biofeedback for respiratory motion management in radiotherapy
    Park, Yang-Kyun
    Kim, Siyong
    Kim, Hwiyoung
    Kim, Il Han
    Lee, Kunwoo
    Ye, Sung-Joon
    [J]. MEDICAL PHYSICS, 2011, 38 (06) : 3114 - 3124
  • [33] Breathing adapted radiotherapy of breast cancer:: reduction of cardiac and pulmonary doses using voluntary inspiration breath-hold
    Pedersen, AN
    Korreman, S
    Nyström, H
    Specht, L
    [J]. RADIOTHERAPY AND ONCOLOGY, 2004, 72 (01) : 53 - 60
  • [34] Breathing guidance in radiation oncology and radiology: A systematic review of patient and healthy volunteer studies
    Pollock, Sean
    Keall, Robyn
    Keall, Paul
    [J]. MEDICAL PHYSICS, 2015, 42 (09) : 5490 - 5509
  • [35] Real-time intra-fraction motion management in breast cancer radiotherapy: analysis of 2028 treatment sessions
    Reitz, D.
    Carl, G.
    Schoenecker, S.
    Pazos, M.
    Freislederer, P.
    Niyazi, M.
    Ganswindt, U.
    Alongi, F.
    Reiner, M.
    Belka, C.
    Corradini, S.
    [J]. RADIATION ONCOLOGY, 2018, 13
  • [36] The use of magnetic sensors to monitor moderate deep inspiration breath hold during breast irradiation with dynamic MLC compensators
    Remouchamps, Vincent M.
    Huyskens, Dominique P.
    Mertens, Ine
    Destine, Michel
    Van Esch, Ann
    Salamon, Emile
    De Neve, Witfried
    [J]. RADIOTHERAPY AND ONCOLOGY, 2007, 82 (03) : 341 - 348
  • [37] Calypso(R) and Laser-Based Localization Systems Comparison for Left-Sided Breast Cancer Patients Using Deep Inspiration Breath Hold
    Robertson, S.
    Kaurin, D.
    Kim, J.
    Fang, L.
    Sweeney, L.
    Holloway, K.
    Tran, A.
    [J]. MEDICAL PHYSICS, 2014, 41 (06) : 162 - +
  • [38] Improving Intra-Fractional Target Position Accuracy Using a 3D Surface Surrogate for Left Breast Irradiation Using the Respiratory-Gated Deep-Inspiration Breath-Hold Technique
    Rong, Yi
    Walston, Steve
    Welliver, Meng Xu
    Chakravarti, Arnab
    Quick, Allison M.
    [J]. PLOS ONE, 2014, 9 (05):
  • [39] Sá AC, 2018, REP PRACT ONCOL RADI, V23, P61, DOI [10.1016/j.rpor.7017.12.007, 10.1016/j.rpor.2017.12.007]
  • [40] Treatment planning and evaluation of gated radiotherapy in left-sided breast cancer patients using the Catalyst™/Sentinel™ system for deep inspiration breath-hold (DIBH)
    Schoenecker, S.
    Walter, F.
    Freislederer, P.
    Marisch, C.
    Scheithauer, H.
    Harbeck, N.
    Corradini, S.
    Belka, C.
    [J]. RADIATION ONCOLOGY, 2016, 11