Accuracy and stability of deep inspiration breath hold in gated breast radiotherapy - A comparison of two tracking and guidance systems

被引:17
作者
Kalet, Alan M. [1 ,2 ]
Cao, Ning [1 ,2 ]
Smith, Wade P. [1 ]
Young, Lori [1 ,2 ]
Wootton, Landon [1 ,2 ]
Stewart, Rob D. [1 ]
Fang, L. Christine [1 ,2 ]
Kim, Janice [1 ,2 ]
Horton, Tony [2 ]
Meyer, Juergen [1 ,2 ]
机构
[1] Univ Washington, Dept Radiat Oncol, Seattle, WA 98195 USA
[2] Seattle Canc Care Alliance, Dept Radiat Oncol, Seattle, WA 98109 USA
来源
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS | 2019年 / 60卷
关键词
Biofeedback; Surface imaging; Motion management; SURFACE-IMAGING-SYSTEM; AUDIOVISUAL BIOFEEDBACK; CLINICAL-EVALUATION; RESPIRATORY MOTION; RADIATION-THERAPY; CANCER PATIENTS; HEART POSITION; SETUP ACCURACY; REPRODUCIBILITY; PATIENT;
D O I
10.1016/j.ejmp.2019.03.025
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To characterize reproducibility of patient breath-hold positioning and compare tracking system performance for Deep Inspiration Breath Hold (DIBH) gated left breast radiotherapy. Methods: 29 consecutive left breast DIBH patients (655 fractions) were treated under the guidance of Calypso surface beacons with audio-feedback and 35 consecutive patients (631 fractions) were treated using C-RAD Catalyst HD surface imaging with audiovisual feedback. The Calypso system tracks a centroid determined by two radio-frequency transponders, with a manually enforced institutional tolerance, while the surface image based CatalystHD system utilizes real-time biometric feedback to track a pre-selected point with an institutional tolerance enforced by the Elekta Response gating interface. DIBH motion data from Calypso was extracted to obtain the displacement of breath hold marker in ant/post direction from a set-zero reference point. Ant/post point displacement data from CatalystHD was interpreted by computing the difference between raw tracking points and the center of individual gating windows. Mean overall errors were compared using Welsh's unequal variance t-test. Wilcoxon rank sum test were used for statistical analysis with P < 0.05 considered significant. Results: Mean overall error for Calypso and CatalystHD were 0.33 +/- 1.17 mm and 0.22 +/- 0.43 mm, respectively, with t-test comparison P-value < 0.034. Absolute errors for Calypso and CatalystHD were 0.95 +/- 0.75 mm and 0.38 +/- 0.30 mm, respectively, with Wilcoxon rank sum test P-value <2 x 10(-16). Average standard deviation per fraction was found to be 0.74 +/- 0.44 mm for Calypso patients versus 0.54 +/- 0.22 mm for CatalystHD. Conclusion: Reduced error distribution widths in overall positioning, deviation of position, and per fraction deviation suggest that the use of functionalities available in CatalystHD such as audiovisual biofeedback and patient surface matching improves accuracy and stability during DIBH gated left breast radiotherapy.
引用
收藏
页码:174 / 181
页数:8
相关论文
共 47 条
  • [1] ALDERLIESTEN T, 2012, INT SOC OPTICS PHOTO, V8316
  • [2] [Anonymous], 2000, R LANG DEF
  • [3] Accuracy of a wireless localization system for radiotherapy
    Balter, JM
    Wright, JN
    Newell, LJ
    Friemel, B
    Dimmer, S
    Cheng, Y
    Wong, J
    Vertatschitsch, E
    Mate, TP
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 61 (03): : 933 - 937
  • [4] Bauer S., 2011, 2011 IEEE International Conference on Computer Vision Workshops (ICCV Workshops), P1175, DOI 10.1109/ICCVW.2011.6130383
  • [5] Validation of the Calypso Surface Beacon Transponder
    Belanger, Maxwell
    Saleh, Ziad
    Volpe, Tom
    Margiasso, Rich
    Li, Xiang
    Chan, Maria
    Zhu, Xiaofeng
    Tang, Xiaoli
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2016, 17 (04): : 223 - 234
  • [6] Assessment of set-up variability during deep inspiration breath hold radiotherapy for breast cancer patients by 3D-surface imaging
    Betgen, Anja
    Alderliesten, Tanja
    Sonke, Jan-Jakob
    van Vliet-Vroegindeweij, Corine
    Bartelink, Harry
    Remeijer, Peter
    [J]. RADIOTHERAPY AND ONCOLOGY, 2013, 106 (02) : 225 - 230
  • [7] Deep Inspiration Breath Hold-Based Radiation Therapy: A Clinical Review
    Boda-Heggemann, Judit
    Knopf, Antje-Christin
    Simeonova-Chergou, Anna
    Wertz, Hansjoerg
    Stieler, Florian
    Jahnke, Anika
    Jahnke, Lennart
    Fleckenstein, Jens
    Vogel, Lena
    Arns, Anna
    Blessing, Manuel
    Wenz, Frederik
    Lohr, Frank
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2016, 94 (03): : 478 - 492
  • [8] Dosimetric and clinical advantages of deep inspiration breath-hold (DIBH) during radiotherapy of breast cancer
    Bruzzaniti, Vicente
    Abate, Armando
    Pinnaro, Paola
    D'Andrea, Marco
    Infusino, Erminia
    Landoni, Valeria
    Soriani, Antonella
    Giordano, Carolina
    Ferraro, Anna Maria
    Strigari, Lidia
    [J]. JOURNAL OF EXPERIMENTAL & CLINICAL CANCER RESEARCH, 2013, 32
  • [9] Using surface imaging and visual coaching to improve the reproducibility and stability of deep-inspiration breath hold for left-breast-cancer radiotherapy
    Cervino, Laura I.
    Gupta, Sonia
    Rose, Mary A.
    Yashar, Catheryn
    Jiang, Steve B.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (22) : 6853 - 6865
  • [10] Automated daily breath hold stability measurements by real-time imaging in radiotherapy of breast cancer
    de Boer, Hans C. J.
    van den Bongard, Desiree J. G.
    van Asselen, Bram
    [J]. RADIOTHERAPY AND ONCOLOGY, 2016, 119 (01) : 61 - 64