Comparison of different fluorescence fluctuation methods for their use in FRET assays:: Monitoring a protease reaction

被引:15
作者
Eggeling, C
Jäger, S
Winkler, D
Kask, P
机构
[1] Max Planck Inst Biophys Chem, Dept NanoBiophoton, D-37077 Gottingen, Germany
[2] Evotec Technol GMBH, Evotec OAI AG, D-22525 Hamburg, Germany
关键词
fluorescence fluctuation Spectroscopy; fluorescence correlation Spectroscopy; fluorescence intensity distribution analysis; Forster resonance energy transfer; confocal microscopy; protease reaction;
D O I
10.2174/138920105774370571
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
We compare the accuracy of a variety of Fluorescence Fluctuation Spectroscopy (FFS) methods for the study of Forster Resonance Energy Transfer (FRET) assays. As an example, the cleavage of a doubly labeled, FRET-active peptide substrate by the protease Trypsin is monitored and analyzed using methods based on fluorescence intensity, Fluorescence Correlation Spectroscopy (FCS) and Fluorescence Intensity Distribution Analysis (FIDA). The presented fluorescerice data are compared to High-Pressure Liquid Chromatography (HPLC) data obtained from the same assay. The HPLC analysis discloses general disadvantages of the FRET approach, such as incomplete labeling and the need for aliquots. However, the simultaneous use of two photon detectors monitoring the fluorescence signal of both labels significantly improves the analysis. In particular, the two global analysis tools Two-Dimensional Fluorescence Intensity Distribution Analysis (2D-FIDA) and Two-Color Global Fluorescence Correlation Spectroscopy (2CG-FCS) highlight the potential of a combination of FFS and FRET. While conventional FIDA and FCS auto- or cross- correlation analysis leaves the user with drawbacks inherent in two-color and FRET applications, these effects are overcome by the global analysis on the molecular level. Furthermore, it is advantageous to analyze the unnormalized as opposed to the normalized correlation data when combining any fluorescence correlation method with FRET, since the analysis of the unnormalized data introduces more accuracy and is less sensitive to the experimental drawbacks.
引用
收藏
页码:351 / 371
页数:21
相关论文
共 78 条
[1]  
Andrews D. L., 1999, RESONANCE ENERGY TRA
[2]   Excitation saturation in two-photon fluorescence correlation spectroscopy [J].
Berland, K ;
Shen, GQ .
APPLIED OPTICS, 2003, 42 (27) :5566-5576
[3]   Detection of specific DNA sequences using dual-color two-photon fluorescence correlation spectroscopy [J].
Berland, KM .
JOURNAL OF BIOTECHNOLOGY, 2004, 108 (02) :127-136
[4]   Ultrasensitive detection of pathological prion protein aggregates by dual-color scanning for intensely fluorescent targets [J].
Bieschke, J ;
Giese, A ;
Schulz-Schaeffer, W ;
Zerr, I ;
Poser, S ;
Eigen, M ;
Kretzschmar, H .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2000, 97 (10) :5468-5473
[5]   Single-molecule fluorescence resonant energy transfer in calcium concentration dependent cameleon [J].
Brasselet, S ;
Peterman, EJG ;
Miyawaki, A ;
Moerner, WE .
JOURNAL OF PHYSICAL CHEMISTRY B, 2000, 104 (15) :3676-3682
[6]   Dual-color photon-counting histogram [J].
Chen, Y ;
Tekmen, M ;
Hillesheim, L ;
Skinner, J ;
Wu, B ;
Müller, JD .
BIOPHYSICAL JOURNAL, 2005, 88 (03) :2177-2192
[7]   The photon counting histogram in fluorescence fluctuation spectroscopy [J].
Chen, Y ;
Müller, JD ;
So, PTC ;
Gratton, E .
BIOPHYSICAL JOURNAL, 1999, 77 (01) :553-567
[8]  
CLEGG RM, 1992, METHOD ENZYMOL, V211, P353
[9]  
Cornish-Bowden A., 2012, FUNDAMENTALS ENZYME
[10]   Ratiometric single-molecule studies of freely diffusing biomolecules [J].
Deniz, AA ;
Laurence, TA ;
Dahan, M ;
Chemla, DS ;
Schultz, PG ;
Weiss, S .
ANNUAL REVIEW OF PHYSICAL CHEMISTRY, 2001, 52 :233-253