Reliability Criteria of Two-Dimensional Shear Wave Elastography: Analysis of 4277 Measurements in 788 Patients

被引:18
作者
Paisant, Anita [1 ,2 ]
Lemoine, Sylvain [1 ]
Cassinotto, Christophe [3 ]
de Ledinghen, Victor [4 ]
Ronot, Maxime [5 ,6 ]
Irles-Depe, Marie [4 ]
Vilgrain, Valerie [5 ,6 ]
Le Bail, Brigitte [7 ]
Paradis, Valerie [8 ]
Canivet, Clemence M. [2 ,9 ]
Michalak, Sophie [2 ,10 ]
Rousselet, Marie-Christine [2 ,10 ]
Rautou, Pierre-Emmanuel [11 ]
Lebigot, Jerome [1 ,2 ]
Hunault, Gilles [2 ]
Crouan, Anne [1 ]
Aube, Christophe [1 ,2 ]
Boursier, Jerome [2 ,9 ]
机构
[1] Ctr Hosp Univ Angers, Dept Radiol, 4 Rue Larrey, F-49933 Angers, France
[2] Univ Angers, SFR 4208, UPRES EA3859, Lab HIFIH, Angers, France
[3] Ctr Hosp Univ Montpellier, Dept Radiol, Hop St Eloi Hosp, Montpellier, France
[4] Ctr Hosp Univ Bordeaux, Serv Hepatogastroenterol, Hop Haut Leveque, Pessac, France
[5] Hop Beaujon, Serv Radiol, HUPNSV, Clichy, France
[6] Univ Paris, INSERM, UMR 1149, Paris, France
[7] Ctr Hosp Univ Bordeaux, Hop Pellegrin, Serv Anatomopathol, Pessac, France
[8] Hop Beaujon, Serv Anatomopathol, HUPNSV, Clichy, France
[9] Ctr Hosp Univ Angers, Serv Hepatogastroenterol, Angers, France
[10] Ctr Hosp Univ Angers, Dept Pathol Cellulaire & Tissulaire, Angers, France
[11] Hop Beaujon, Serv Hepatol, HUPNSV, Clichy, France
关键词
Liver Stiffness; 2D-SWE; Liver Fibrosis; Cirrhosis; Reliability; LIVER STIFFNESS MEASUREMENTS; INTRAOBSERVER; DIAGNOSIS; FIBROSIS; TIMES;
D O I
10.1016/j.cgh.2020.12.013
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
BACKGROUND & AIMS: Two-dimensional shear wave elastography (2D-SWE) is an accurate method for the non-invasive evaluation of liver fibrosis. We aimed to determine the reliability criteria and the number of necessary reliable measurements for 2D-SWE. METHODS: 788 patients with chronic liver disease underwent liver biopsy and 2D-SWE examination in three centers. The 4277 2D-SWE measurements performed were 2:1 randomly divided into derivation (n = 2851) and validation (n = 1426) sets. Reliability criteria for a 2D-SWE measurement were defined in the derivation set from the intrinsic characteristics given by the device (mean liver stiffness, standard deviation, diameter of the region of interest), with further evaluation in the validation set. RESULTS: In the whole population of 4277 measurements, AUROC for bridging fibrosis was 0.825 +/- 0.006 and AUROC for cirrhosis was 0.880 +/- 0.006. Mean stiffness and coefficient of variation (CV) were independent predictors of bridging fibrosis or cirrhosis. From these two parameters, new criteria were derived to define a reliable 2D-SWE measurement: stiffness <8.8 kPa, or stiffness between 8.8-11.9 kPa with CV <0.25, or stiffness >= 12.0 kPa with CV <0.10. In the validation set, AUROC for bridging fibrosis was 0.830 +/- 0.013 in reliable measurements vs 0.667 +/- 0.031 in unreliable measurements (P < .001). AUROC for cirrhosis was 0.918 +/- 0.014 vs 0.714 +/- 0.027, respectively (P < .001). The best diagnostic accuracy for a 2D-SWE examination was achieved from three reliable measurements. CONCLUSIONS: Reliability of a 2D-SWE measurement relies on the coefficient of variation and the liver stiffness level. A 2D-SWE examination should include three reliable measurements according to our new criteria.
引用
收藏
页码:400 / +
页数:19
相关论文
共 23 条
[1]  
BEDOSSA P, 1994, HEPATOLOGY, V20, P15
[2]   Factors associated with the impossibility to obtain reliable liver stiffness measurements by means of Acoustic Radiation Force Impulse (ARFI) elastography-Analysis of a cohort of 1031 subjects [J].
Bota, Simona ;
Sporea, Ioan ;
Sirli, Roxana ;
Popescu, Alina ;
Danila, Mirela ;
Jurchis, Ana ;
Gradinaru-Tascau, Oana .
EUROPEAN JOURNAL OF RADIOLOGY, 2014, 83 (02) :268-272
[3]   Criteria to Determine Reliability of Noninvasive Assessment of Liver Fibrosis With Virtual Touch Quantification [J].
Boursier, Jerome ;
Cassinotto, Christophe ;
Hunault, Gilles ;
Shili, Sarah ;
Lebigot, Jerome ;
Lapuyade, Bruno ;
Lannes, Adrien ;
Hiriart, Jean-Baptiste ;
Cartier, Victoire ;
Le Bail, Brigitte ;
Michalak, Sophie ;
Mouries, Amaury ;
Oberti, Frederic ;
Chermak, Faiza ;
Fouchard-Hubert, Isabelle ;
Cales, Paul ;
Aube, Christophe ;
de Ledinghen, Victor .
CLINICAL GASTROENTEROLOGY AND HEPATOLOGY, 2019, 17 (01) :164-+
[4]   A stepwise algorithm using an at-a-glance first-line test for the non-invasive diagnosis of advanced liver fibrosis and cirrhosis [J].
Boursier, Jerome ;
de Ledinghen, Victor ;
Leroy, Vincent ;
Anty, Rodolphe ;
Francque, Sven ;
Salmon, Dominique ;
Lannes, Adrien ;
Bertrais, Sandrine ;
Oberti, Frederic ;
Fouchard-Hubert, Isabelle ;
Cales, Paul .
JOURNAL OF HEPATOLOGY, 2017, 66 (06) :1158-1165
[5]   An extension of STARD statements for reporting diagnostic accuracy studies on liver fibrosis tests: The Liver-FibroSTARD standards [J].
Boursier, Jerome ;
de Ledinghen, Victor ;
Poynard, Thierry ;
Guechot, Jerome ;
Carrat, Fabrice ;
Leroy, Vincent ;
Wong, Grace Lai-Hung ;
Friedrich-Rust, Mireen ;
Fraquelli, Mirella ;
Plebani, Mario ;
Sebastiani, Giada ;
Myers, Robert ;
Angulo, Paul ;
Bertrais, Sandrine ;
Wendum, Dominique ;
Bricault, Ivan ;
Cales, Paul .
JOURNAL OF HEPATOLOGY, 2015, 62 (04) :807-815
[6]   Determination of reliability criteria for liver stiffness evaluation by transient elastography [J].
Boursier, Jerome ;
Zarski, Jean-Pierre ;
de Ledinghen, Victor ;
Rousselet, Marie-Christine ;
Sturm, Nathalie ;
Lebail, Brigitte ;
Fouchard-Hubert, Isabelle ;
Gallois, Yves ;
Oberti, Frederic ;
Bertrais, Sandrine ;
Cales, Paul .
HEPATOLOGY, 2013, 57 (03) :1182-1191
[7]   Liver Stiffness in Nonalcoholic Fatty Liver Disease: A Comparison of Supersonic Shear Imaging, FibroScan, and ARFI With Liver Biopsy [J].
Cassinotto, Christophe ;
Boursier, Jerome ;
de Ledinghen, Victor ;
Lebigot, Jerome ;
Lapuyade, Bruno ;
Cales, Paul ;
Hiriart, Jean-Baptiste ;
Michalak, Sophie ;
Le Bail, Brigitte ;
Cartier, Victoire ;
Mouries, Amaury ;
Oberti, Frederic ;
Fouchard-Hubert, Isabelle ;
Vergniol, Julien ;
Aube, Christophe .
HEPATOLOGY, 2016, 63 (06) :1817-1827
[8]   How many times should we repeat measuring liver stiffness using shear wave elastography?: 5-repetition versus 10-repetition protocols [J].
Choi, Seung Hee ;
Jeong, Woo Kyoung ;
Kim, Yongsoo ;
Lim, Sanghyeok ;
Kwon, Jong Won ;
Kim, Tae Yeob ;
Kim, Min Yeong ;
Sohn, Joo Hyun .
ULTRASONICS, 2016, 72 :158-164
[9]  
Collins GS, 2015, BMJ-BRIT MED J, V350, DOI [10.1136/bmj.g7594, 10.1111/1471-0528.13244]
[10]   COMPARING THE AREAS UNDER 2 OR MORE CORRELATED RECEIVER OPERATING CHARACTERISTIC CURVES - A NONPARAMETRIC APPROACH [J].
DELONG, ER ;
DELONG, DM ;
CLARKEPEARSON, DI .
BIOMETRICS, 1988, 44 (03) :837-845