Regional Hounsfield unit measurement of screw trajectory for predicting pedicle screw fixation using cortical bone trajectory: a retrospective cohort study

被引:36
|
作者
Matsukawa, Keitaro [1 ]
Abe, Yuichiro [2 ]
Yanai, Yoshihide [1 ]
Yato, Yoshiyuki [1 ]
机构
[1] Natl Hosp Org, Murayama Med Ctr, Dept Orthopaed Surg, Musashimurayama, Tokyo, Japan
[2] Wajokai Eniwa Hosp, Dept Orthopaed Surg, Eniwa, Hokkaido, Japan
关键词
Hounsfield units; Pedicle screw fixation; Screw loosening; Insertional torque; Bone density; Simulation analysis; Cortical bone trajectory; PULL-OUT STRENGTH; MINERAL DENSITY; INSERTIONAL TORQUE; IN-VITRO; STABILITY; FUSION; SPINE;
D O I
10.1007/s00701-017-3424-5
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background The sufficiency of screw anchoring is a critical factor for achieving successful spinal fusion; however, no reliable method for predicting pedicle screw fixation has been established. Recently, Hounsfield units (HU) obtained from computed tomography (CT) was developed as a new reliable tool to determine the bone quality. The purpose of the present study was to demonstrate the utility of regional HU measurement of the screw trajectory to predict the primary and long-term fixation strength of pedicle screws. Method The insertional torque of pedicle screws using the cortical bone trajectory technique was measured intraoperatively in 92 consecutive patients who underwent single-level posterior lumbar interbody fusion. The cylindrical area of each screw was plotted on the preoperative CT image by precisely confirming the screw position, and the screw trajectory was measured in HU. First, three parameters: the bone mineral density (BMD) of the femoral neck and lumbar vertebrae, and regional HU values of the screw trajectory, were correlated with the insertional torque and compared among three groups. Next, pedicle screw loosening was evaluated by postoperative CT obtained 12 months after surgery, and clinical and imaging data were analyzed to assess whether regional HU values could be used as a predictor of screw loosening. Results Regional HU values of the screw trajectory (r = 0.75, p < 0.001) had stronger correlation with the insertional torque than the femoral BMD (r = 0.59, p < 0.001) and lumbar BMD (r = 0.55, p < 0.001). The incidence of screw loosening was 4.6% (16/351). Multivariate logistic regression analysis revealed that regional HU value (odds ratio = 0.70; 95% confidence interval = 0.56-0.84; p = 0.018) was an independent risk factor significantly affected screw loosening. Conclusions Regional HU values of the screw trajectory could be a strong predictor of both primary and long-term screw fixation in vivo.
引用
收藏
页码:405 / 411
页数:7
相关论文
共 50 条
  • [41] Three-Dimensional Patient-Specific Guides for Intraoperative Navigation for Cortical Screw Trajectory Pedicle Fixation
    Kim, Jiwon
    Rajadurai, Jeremy
    Choy, Wen Jie
    Cassar, Lachlan
    Phan, Kevin
    Harris, Leigh
    Fiechter, Meinrad
    Mobbs, Ralph J.
    WORLD NEUROSURGERY, 2019, 122 : 674 - 679
  • [42] Incidence and Risk Factors of Adjacent Cranial Facet Joint Violation Following Pedicle Screw Insertion Using Cortical Bone Trajectory Technique
    Matsukawa, Keitaro
    Kato, Takashi
    Yato, Yoshiyuki
    Sasao, Hiroshi
    Imabayashi, Hideaki
    Hosogane, Naobumi
    Asazuma, Takashi
    Chiba, Kazuhiro
    SPINE, 2016, 41 (14) : E851 - E856
  • [43] Short-Term Results of Transforaminal Lumbar Interbody Fusion Using Pedicle Screw with Cortical Bone Trajectory Compared with Conventional Trajectory
    Kasukawa, Yuji
    Miyakoshi, Naohisa
    Hongo, Michio
    Ishikawa, Yoshinori
    Kudo, Daisuke
    Shimada, Yoichi
    ASIAN SPINE JOURNAL, 2015, 9 (03) : 440 - 448
  • [44] Cortical bone trajectory and traditional trajectory—a radiological evaluation of screw-bone contact
    Kota Kojima
    Shunji Asamoto
    Yoshiomi Kobayashi
    Masayuki Ishikawa
    Yasuyuki Fukui
    Acta Neurochirurgica, 2015, 157 : 1173 - 1178
  • [45] Midline Lumbar Fusion with Cortical Bone Trajectory Screw
    Mizuno, Masaki
    Kuraishi, Keita
    Umeda, Yasuyuki
    Sano, Takanori
    Tsuji, Masanori
    Suzuki, Hidenori
    NEUROLOGIA MEDICO-CHIRURGICA, 2014, 54 (09) : 716 - 721
  • [46] Minimally invasive dynamic screw stabilization using cortical bone trajectory
    Chang, Chih-Chang
    Kuo, Chao-Hung
    Chang, Hsuan-Kan
    Tu, Tsung-Hsi
    Fay, Li-Yu
    Wu, Jau-Ching
    Cheng, Henrich
    Huang, Wen-Cheng
    BMC MUSCULOSKELETAL DISORDERS, 2020, 21 (01)
  • [47] Fixation Strength of Caudal Pedicle Screws after Posterior Lumbar Interbody Fusion with the Modified Cortical Bone Trajectory Screw Method
    Sakaura, Hironobu
    Miwa, Toshitada
    Yamashita, Tomoya
    Kuroda, Yusuke
    Ohwada, Tetsuo
    ASIAN SPINE JOURNAL, 2016, 10 (04) : 639 - 645
  • [48] Comparative Study of Two Surgical Techniques for Proximal Adjacent Segment Pathology after Posterior Lumbar Interbody Fusion with Pedicle Screws: Fusion Extension using Conventional Pedicle Screw vs Cortical Bone Trajectory-Pedicle Screw (Cortical Screw)
    Lee, Gun Woo
    Shin, Ji-Hoon
    WORLD NEUROSURGERY, 2018, 117 : E154 - E161
  • [49] Combination of sacral-alar-iliac screw and cortical bone trajectory screw techniques for lumbosacral fixation: technical note
    Matsukawa, Keitaro
    Kato, Takashi
    Mobbs, Ralph
    Yato, Yoshiyuki
    Asazuma, Takashi
    JOURNAL OF NEUROSURGERY-SPINE, 2020, 33 (02) : 186 - 191
  • [50] Comparison of cortical bone trajectory versus pedicle screw techniques in lumbar fusion surgery A meta-analysis
    Hu, Jing-Nan
    Yang, Xiao-Feng
    Li, Chuan-Ming
    Li, Xin-Xin
    Ding, Yun-Zhi
    MEDICINE, 2019, 98 (33)