Regional Hounsfield unit measurement of screw trajectory for predicting pedicle screw fixation using cortical bone trajectory: a retrospective cohort study

被引:36
|
作者
Matsukawa, Keitaro [1 ]
Abe, Yuichiro [2 ]
Yanai, Yoshihide [1 ]
Yato, Yoshiyuki [1 ]
机构
[1] Natl Hosp Org, Murayama Med Ctr, Dept Orthopaed Surg, Musashimurayama, Tokyo, Japan
[2] Wajokai Eniwa Hosp, Dept Orthopaed Surg, Eniwa, Hokkaido, Japan
关键词
Hounsfield units; Pedicle screw fixation; Screw loosening; Insertional torque; Bone density; Simulation analysis; Cortical bone trajectory; PULL-OUT STRENGTH; MINERAL DENSITY; INSERTIONAL TORQUE; IN-VITRO; STABILITY; FUSION; SPINE;
D O I
10.1007/s00701-017-3424-5
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background The sufficiency of screw anchoring is a critical factor for achieving successful spinal fusion; however, no reliable method for predicting pedicle screw fixation has been established. Recently, Hounsfield units (HU) obtained from computed tomography (CT) was developed as a new reliable tool to determine the bone quality. The purpose of the present study was to demonstrate the utility of regional HU measurement of the screw trajectory to predict the primary and long-term fixation strength of pedicle screws. Method The insertional torque of pedicle screws using the cortical bone trajectory technique was measured intraoperatively in 92 consecutive patients who underwent single-level posterior lumbar interbody fusion. The cylindrical area of each screw was plotted on the preoperative CT image by precisely confirming the screw position, and the screw trajectory was measured in HU. First, three parameters: the bone mineral density (BMD) of the femoral neck and lumbar vertebrae, and regional HU values of the screw trajectory, were correlated with the insertional torque and compared among three groups. Next, pedicle screw loosening was evaluated by postoperative CT obtained 12 months after surgery, and clinical and imaging data were analyzed to assess whether regional HU values could be used as a predictor of screw loosening. Results Regional HU values of the screw trajectory (r = 0.75, p < 0.001) had stronger correlation with the insertional torque than the femoral BMD (r = 0.59, p < 0.001) and lumbar BMD (r = 0.55, p < 0.001). The incidence of screw loosening was 4.6% (16/351). Multivariate logistic regression analysis revealed that regional HU value (odds ratio = 0.70; 95% confidence interval = 0.56-0.84; p = 0.018) was an independent risk factor significantly affected screw loosening. Conclusions Regional HU values of the screw trajectory could be a strong predictor of both primary and long-term screw fixation in vivo.
引用
收藏
页码:405 / 411
页数:7
相关论文
共 50 条
  • [31] Bone density comparison between the normal pedicle trajectory, cortical bone trajectory, and modified cortical bone trajectory using computed tomography: a crosssectional study
    Parajuli, Bikash
    Shrestha, Dipak
    Abumi, Kuniyoshi
    Kayastha, Sabik
    Thapa, Jagadish
    Sharma, Sanjay
    Lamichhane, Suman
    Deininger, Christian
    ASIAN SPINE JOURNAL, 2025,
  • [32] Comparison of Clinical Outcomes After Transforaminal Interbody Fusion Using Cortical Bone Trajectory versus Percutaneous Pedicle Screw Fixation
    Maruo, Keishi
    Arizumi, Fumihiro
    Kusuyama, Kazuki
    Yoshie, Norichika
    Tomoyuki, Kusukawa
    Tachibana, Toshiya
    WORLD NEUROSURGERY, 2021, 151 : E821 - E827
  • [33] Depth of vertebral screw insertion using a cortical bone trajectory technique in lumbar spinal fusion: radiological significance of a long cortical bone trajectory
    Matsukawa, Keitaro
    Yanai, Yoshihide
    Fujiyoshi, Kanehiro
    Kato, Takashi
    Yato, Yoshiyuki
    JOURNAL OF NEUROSURGERY-SPINE, 2021, 35 (05) : 601 - 606
  • [34] Anatomical research on strength of screw track fixation in novel cortical bone trajectory for osteoporosis lumbar spine
    Rexiti, Paerhati
    Aierken, Gulixian
    Wang, Shuiquan
    Abudurexiti, Tuerhongjiang
    Abuduwali, Nueraihemaiti
    Deng, Qiang
    Guo, Hailong
    Sheng, Weibin
    AMERICAN JOURNAL OF TRANSLATIONAL RESEARCH, 2019, 11 (11): : 6850 - 6859
  • [35] Biomechanical comparative study of midline cortical vs. traditional pedicle screw trajectory in osteoporotic bone
    Schleifenbaum, Stefan
    Vogl, Ann-Cathrin
    Heilmann, Robin
    von der Hoeh, Nicolas Heinz
    Heyde, Christoph-Eckhard
    Jarvers, Jan-Sven
    BMC MUSCULOSKELETAL DISORDERS, 2023, 24 (01)
  • [36] Comparative clinical efficacy and safety of cortical bone trajectory screw fixation and traditional pedicle screw fixation in posterior lumbar fusion: a systematic review and meta-analysis
    Wang, Jizhou
    He, Xiaoqi
    Sun, Tianwei
    EUROPEAN SPINE JOURNAL, 2019, 28 (07) : 1678 - 1689
  • [37] Comparative clinical efficacy and safety of cortical bone trajectory screw fixation and traditional pedicle screw fixation in posterior lumbar fusion: a systematic review and meta-analysis
    Jizhou Wang
    Xiaoqi He
    Tianwei Sun
    European Spine Journal, 2019, 28 : 1678 - 1689
  • [38] Radiological Evaluation of the Initial Fixation between Cortical Bone Trajectory and Conventional Pedicle Screw Technique for Lumbar Degenerative Spondylolisthesis
    Ninomiya, Koshi
    Iwatsuki, Koichi
    Ohnishi, Yu-Ichiro
    Yoshimine, Toshiki
    ASIAN SPINE JOURNAL, 2016, 10 (02) : 251 - 257
  • [39] Is a cross-connector beneficial for single level traditional or cortical bone trajectory pedicle screw instrumentation?
    Cornaz, Frederic
    Widmer, Jonas
    Fasser, Marie-Rosa
    Snedeker, Jess Gerrit
    Matsukawa, Keitaro
    Spirig, Jose Miguel
    Farshad, Mazda
    PLOS ONE, 2021, 16 (06):
  • [40] Comparative Outcomes of Cortical Bone Trajectory Screw Fixation and Traditional Pedicle Screws in Lumbar Fusion: A Meta-Analysis
    Qiu, Ling
    Niu, Fei
    Wu, Zhedong
    Zhang, Wei
    Chen, Feifei
    Tan, Jun
    Yan, Jun
    Xia, Ping
    WORLD NEUROSURGERY, 2022, 164 : E436 - E445