Speech-evoked activation in adult temporal cortex measured using functional near-infrared spectroscopy (fNIRS): Are the measurements reliable?

被引:58
|
作者
Wiggins, Ian M. [1 ,2 ,3 ]
Anderson, Carly A. [1 ,2 ]
Kitterick, Padraig T. [1 ,2 ]
Hartley, Douglas E. H. [1 ,2 ,3 ,4 ]
机构
[1] Natl Inst Hlth Res NIHR Nottingham Hearing Biomed, 113 Ropewalk, Nottingham NG1 5DU, England
[2] Univ Nottingham, Sch Med, Div Clin Neurosci, Otol & Hearing Grp, Nottingham NG7 2UH, England
[3] Univ Nottingham, MRC, Inst Hearing Res, Univ Pk, Nottingham NG7 2RD, England
[4] Nottingham Univ Hosp NHS Trust, Derby Rd, Nottingham NG7 2UH, England
关键词
Auditory cortex; fNIRS; Functional near-infrared spectroscopy; Speech; Speechreading; Test-retest reliability; TEST-RETEST RELIABILITY; FALSE DISCOVERY RATE; AUDITORY-CORTEX; BRAIN ACTIVATION; REPRODUCIBILITY; TASK; PROPAGATION; ARTIFACTS; RESPONSES; REMOVAL;
D O I
10.1016/j.heares.2016.07.007
中图分类号
R36 [病理学]; R76 [耳鼻咽喉科学];
学科分类号
100104 ; 100213 ;
摘要
Functional near-infrared spectroscopy (fNIRS) is a silent, non-invasive neuroimaging technique that is potentially well suited to auditory research. However, the reliability of auditory-evoked activation measured using fNIRS is largely unknown. The present study investigated the test-retest reliability of speech-evoked fNIRS responses in normally-hearing adults. Seventeen participants underwent fNIRS imaging in two sessions separated by three months. In a block design, participants were presented with auditory speech, visual speech (silent speechreading), and audiovisual speech conditions. Optode arrays were placed bilaterally over the temporal lobes, targeting auditory brain regions. A range of established metrics was used to quantify the reproducibility of cortical activation patterns, as well as the amplitude and time course of the haemodynamic response within predefined regions of interest. The use of a signal processing algorithm designed to reduce the influence of systemic physiological signals was found to be crucial to achieving reliable detection of significant activation at the group level. For auditory speech (with or without visual cues), reliability was good to excellent at the group level, but highly variable among individuals. Temporal-lobe activation in response to visual speech was less reliable, especially in the right hemisphere. Consistent with previous reports, fNIRS reliability was improved by averaging across a small number of channels overlying a cortical region of interest. Overall, the present results confirm that fNIRS can measure speech-evoked auditory responses in adults that are highly reliable at the group level, and indicate that signal processing to reduce physiological noise may substantially improve the reliability of fNIRS measurements. (C) 2016 The Authors. Published by Elsevier B.V. This is an open access article under the CC BY license.
引用
收藏
页码:142 / 154
页数:13
相关论文
共 50 条
  • [21] Effective Learning Material for English (L2) Assessed in Terms of Brain Activation Using Functional Near-Infrared Spectroscopy (fNIRS)
    Nakano, Hideko
    Ueda, Masanobu
    Natsume, Kiyohisa
    Inoue, Masao
    So, Mari
    12TH INTERNATIONAL CONFERENCE INNOVATION IN LANGUAGE LEARNING, 2019, : 374 - 379
  • [22] How Stress Affects Functional Near-Infrared Spectroscopy (fNIRS) Measurements of Mental Workload
    Alsuraykh, Norah H.
    Maior, Horia A.
    Wilson, Max L.
    Tennent, Paul
    Sharples, Sarah
    CHI 2018: EXTENDED ABSTRACTS OF THE 2018 CHI CONFERENCE ON HUMAN FACTORS IN COMPUTING SYSTEMS, 2018,
  • [23] Cortical activation patterns to spatially presented pure tone stimuli with different intensities measured by functional near-infrared spectroscopy
    Bauernfeind, Guenther
    Wriessnegger, Selina C.
    Haumann, Sabine
    Lenarz, Thomas
    HUMAN BRAIN MAPPING, 2018, 39 (07) : 2710 - 2724
  • [24] Involvement of the prefrontal cortex in motor sequence learning: A functional near-infrared spectroscopy (fNIRS) study
    Polskaia, Nadia
    St-Amant, Gabrielle
    Fraser, Sarah
    Lajoie, Yves
    BRAIN AND COGNITION, 2023, 166
  • [25] Mental workload classification and measurement using functional near-infrared spectroscopy (fNIRS)
    Pan, Jinjin
    Jiao, Xuejun
    Wang, Chunhui
    Chen, Shanguang
    Jiao, Dian
    Jiang, Jin
    Zhang, Zhen
    Guangxue Xuebao/Acta Optica Sinica, 2015, 35
  • [26] Human central auditory plasticity: A review of functional near-infrared spectroscopy (fNIRS) to measure cochlear implant performance and tinnitus perception
    Basura, Gregory J.
    Hu, Xiao-Su
    Juan, Juan San
    Tessier, Anne-Michelle
    Kovelman, Ioulia
    LARYNGOSCOPE INVESTIGATIVE OTOLARYNGOLOGY, 2018, 3 (06): : 463 - 472
  • [27] FUNCTIONAL NEAR-INFRARED SPECTROSCOPY (fNIRS): DEVELOPMENT AND APPLICATIONS IN NEUROSCIENCE
    Cinciute, Sigita
    Daktariunas, Algis
    Ruksenas, Osvaldas
    MEDICAL PHYSICS IN THE BALTIC STATES, 2013, : 75 - 78
  • [28] Applying functional near-infrared spectroscopy (fNIRS) in educational research: a systematic review
    Zhan, Zehui
    Yang, Qinchen
    Luo, Lixia
    Zhang, Xia
    CURRENT PSYCHOLOGY, 2024, 43 (11) : 9676 - 9691
  • [29] Applications of Functional Near-Infrared Spectroscopy (fNIRS) in Studying Cognitive Development: The Case of Mathematics and Language
    Soltanlou, Mojtaba
    Sitnikova, Maria A.
    Nuerk, Hans-Christoph
    Dresler, Thomas
    FRONTIERS IN PSYCHOLOGY, 2018, 9
  • [30] Correlation between LIFG and Autonomic Activation during Stressful Tasks: A Functional Near-infrared Spectroscopy (fNIRS) Study
    Shi, Jie
    Sakatani, Kaoru
    Okamoto, Masako
    Yamaguchi, Yui
    Zuo, Huan-cong
    JOURNAL OF HUAZHONG UNIVERSITY OF SCIENCE AND TECHNOLOGY-MEDICAL SCIENCES, 2014, 34 (05) : 663 - 671