Hybrid biocomposites based on titania nanotubes and a hydroxyapatite coating deposited by RF-magnetron sputtering: Surface topography, structure, and mechanical properties

被引:54
作者
Chernozem, Roman V. [1 ]
Surmeneva, Maria A. [1 ]
Krause, Baerbel [2 ]
Baumbach, Tilo [2 ,3 ]
Ignatov, Viktor P. [4 ]
Tyurin, Alexander I. [5 ]
Loza, Kateryna [6 ,7 ]
Epple, Matthias [6 ,7 ]
Surmenev, Roman A. [1 ]
机构
[1] Natl Res Tomsk Polytech Univ, Dept Expt Phys, Ctr Technol, Tomsk 634050, Russia
[2] Karlsruhe Inst Technol, ANKA Inst Photon Sci & Synchrotron Radiat IPS, D-76344 Eggenstein Leopoldshafen, Germany
[3] Karlsruhe Inst Technol, Lab Applicat Synchrotron Radiat LAS, D-76049 Karlsruhe, Germany
[4] Natl Res Tomsk Polytech Univ, Dept Silicate Technol & Nanomat, Tomsk 634050, Russia
[5] GR Derzhavin Tambov State Univ, NanoCtr Nanotechnol & Nanomat, Tambov 392000, Russia
[6] Univ Duisburg Essen, Inorgan Chem, D-45117 Essen, Germany
[7] Univ Duisburg Essen, Ctr Nanointegrat Duisburg Essen CeNIDE, D-45117 Essen, Germany
关键词
Titanium oxide nanotubes; Hydroxyapatite; Amorphous calcium phosphate; Magnetron sputtering; Bone tissue engineering; Nanohardness; Young's modulus; TIO2; NANOTUBES; CALCIUM PHOSPHATES; ANODIC-OXIDATION; ELECTROCHEMICAL FORMATION; TREATED TITANIUM; TA6V ALLOY; IN-VITRO; ARRAYS; FILMS; FABRICATION;
D O I
10.1016/j.apsusc.2017.07.199
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
In this study, biocomposites based on porous titanium oxide structures and a calcium phosphate (CaP) or hydroxyapatite (HA) coating are described and prepared. Nanotubes (NTs) with different pore dimensions were processed using anodic oxidation of Ti substrates in a NH4F-containing electrolyte solution at anodization voltages of 30V and 60 V with a DC power supply. The external diameters of the nanotubes prepared at 30 V and 60 V were 53 +/- 10 and 98 +/- 16 nm, respectively. RF-magnetron sputtering of the HA target in a single deposition run was performed to prepare a coating on the surface of TiO2 NTs prepared at 30 and 60 V. The thickness of the CaP coating deposited on the mirror-polished Si substrate in the same deposition run with TiO2 NTs was determined by optical ellipsometry (SE) 95 +/- 5 nm. Uncoated and CaP-coated NTs were annealed at 500 degrees C in air. Afterwards, the presence of TiO2 (anatase) was observed. The scanning electron microscopy (SEM), X-ray diffraction (XRD), photoelectron spectroscopy (XPS) and nanoindentation results revealed the influence that the NT dimensions had on the CaP coating deposition process. The tubular surfaces of the NTs were completely coated with the HA coating when prepared at 30 V, and no homogeneous CaP coating was observed when prepared at 60 V. The XRD patterns show peaks assigned to crystalline HA only for the coated TiO2 NTs prepared at 30 V. High-resolution XPS spectra show binding energies (BE) of Ca 2p, P 2p and O 1s core-levels corresponding to HA and amorphous calcium phosphate on TiO2 NTs prepared at 30 V and 60 V, respectively. Fabrication of TiO2 NTs results in a significant decrease to the elastic modulus and nanohardness compared to the Ti substrate. The porous structure of the NTs causes an increase in the elastic strain to failure of the coating (H/E ) and the parameter used to describe the resistance of the material to plastic deformation (H-3/E-2) at the nanoscale level compared to the Ti substrate. Furthermore, only the HA coating on the NTs exhibits a significantly increased H/E ratio and H-3/E-2 factor compared to the NTs and Ti substrate. Increases in resistance to penetration for the indenter were also observed for HA-coated TiO2 NTs prepared at 30 V compared to uncoated and CaP-coated NTs prepared at 60 V. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:229 / 237
页数:9
相关论文
共 80 条
  • [1] ASSEFPOURDEZFULY M, 1984, J MATER SCI, V19, P3626, DOI 10.1007/BF02396935
  • [2] Surface modification of titanium by etching in concentrated sulfuric acid
    Ban, Seiji
    Iwaya, Yukari
    Kono, Hiroshi
    Sato, Hideo
    [J]. DENTAL MATERIALS, 2006, 22 (12) : 1115 - 1120
  • [3] VARIATIONS IN STRENGTH AND STRUCTURE OF CANCELLOUS BONE AT KNEE
    BEHRENS, JC
    WALKER, PS
    SHOJI, H
    [J]. JOURNAL OF BIOMECHANICS, 1974, 7 (03) : 201 - 207
  • [4] Black J., 2013, HDB BIOMATERIAL PROP
  • [5] Comparative cell behavior on carbon-coated TiO2 nanotube surfaces for osteoblasts vs. osteo-progenitor cells
    Brammer, Karla S.
    Choi, Chulmin
    Frandsen, Christine J.
    Oh, Seunghan
    Johnston, Gary
    Jin, Sungho
    [J]. ACTA BIOMATERIALIA, 2011, 7 (06) : 2697 - 2703
  • [6] Improved bone-forming functionality on diameter-controlled TiO2 nanotube surface
    Brammer, Karla S.
    Oh, Seunghan
    Cobb, Christine J.
    Bjursten, Lars M.
    van der Heyde, Henri
    Jin, Sungho
    [J]. ACTA BIOMATERIALIA, 2009, 5 (08) : 3215 - 3223
  • [7] VARIABLE WAVELENGTH, VARIABLE ANGLE ELLIPSOMETRY INCLUDING A SENSITIVITIES CORRELATION TEST
    BUABBUD, GH
    BASHARA, NM
    WOOLLAM, JA
    [J]. THIN SOLID FILMS, 1986, 138 (01) : 27 - 41
  • [8] The effect of electrolyte composition on the fabrication of self-organized titanium oxide nanotube arrays by anodic oxidation
    Cai, QY
    Paulose, M
    Varghese, OK
    Grimes, CA
    [J]. JOURNAL OF MATERIALS RESEARCH, 2005, 20 (01) : 230 - 236
  • [9] Chastain J., 1995, Handbook of X--ray photoelectron spectroscopy: a reference book of standard spectra for identification and interpretation of XPS data
  • [10] Influence of Anodization Time and Voltage on the Parameters of TiO2 Nanotubes
    Chernozem, R. V.
    Surmeneva, M. A.
    Surmenev, R. A.
    [J]. INTERNATIONAL CONFERENCE ON ADVANCED MATERIALS AND NEW TECHNOLOGIES IN MODERN MATERIALS SCIENCE 2015, 2016, 116