The influence of cement viscosity on the early migration of a tapered polished femoral stem

被引:22
作者
Glyn-Jones, S [1 ]
Hicks, J [1 ]
Alfaro-Adrian, J [1 ]
Gill, HS [1 ]
McLardy-Smith, P [1 ]
Murray, DW [1 ]
机构
[1] Nuffield Orthopaed Ctr, Oxford Orthopaed Engn Ctr, Oxford OX3 7LD, England
关键词
D O I
10.1007/s00264-003-0500-7
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
It is unclear whether it is best to use high-viscosity or low-viscosity cement for fixation of total hip replacement (THR) femoral components. This study examines the influence of cement viscosity on the migration of the Exeter femoral component using roentgen stereophotogrammetric analysis (RSA). Simplex, CMW1 and CMW3 G cements were examined in a total of 46 patients over a 12-month period. The overall pattern of migration for all cohorts was one of subsidence and rotation into valgus. There was no significant difference in any aspect of migration between the groups. In vitro studies demonstrate that low-viscosity cement forms a more stable bone-cement interface. Several groups have examined the in vivo effect of cement viscosity on stem longevity with conflicting results. For a polished, tapered implant that is designed to subside, cement viscosity does not influence the 1-year migration, and it is therefore unlikely to affect long-term outcome.
引用
收藏
页码:362 / 365
页数:4
相关论文
共 17 条
  • [1] Cement migration after THR -: A comparison of Charnley Elite and Exeter femoral stems using RSA
    Alfaro-Adrián, J
    Gill, HS
    Murray, DW
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1999, 81B (01): : 130 - 134
  • [2] Should total hip arthroplasty femoral components be designed to subside?: A radiostereometric analysis study of the Charnley Elite and Exeter stems
    Alfaro-Adrián, J
    Gill, HS
    Murray, DW
    [J]. JOURNAL OF ARTHROPLASTY, 2001, 16 (05) : 598 - 606
  • [3] Altman DG, 1996, Practical Statistics for Medical Research
  • [4] The Norwegian Arthroplasty Register -: 11 years and 73,000 arthroplasties
    Havelin, LI
    Engesæter, LB
    Espehaug, B
    Furnes, O
    Lie, SA
    Vollset, SE
    [J]. ACTA ORTHOPAEDICA SCANDINAVICA, 2000, 71 (04): : 337 - 353
  • [5] THE EFFECT OF THE TYPE OF CEMENT ON EARLY REVISION OF CHARNLEY TOTAL HIP PROSTHESES - A REVIEW OF 8,579 PRIMARY ARTHROPLASTIES FROM THE NORWEGIAN ARTHROPLASTY REGISTER
    HAVELIN, LI
    ESPEHAUG, B
    VOLLSET, SE
    ENGESAETER, LB
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1995, 77 (10) : 1543 - 1550
  • [6] Karrholm J, 1997, CLIN ORTHOP RELAT R, P94
  • [7] Early radiological observations may predict the long-term survival of femoral hip prostheses
    Kobayashi, A
    Donnelly, WJ
    Scott, G
    Freeman, MAR
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1997, 79B (04): : 583 - 589
  • [8] KUHN KD, 2001, BONE CEMENTS CEMENTI
  • [9] Lewis G, 1997, J BIOMED MATER RES, V38, P155, DOI 10.1002/(SICI)1097-4636(199722)38:2<155::AID-JBM10>3.0.CO
  • [10] 2-C