Measurement uncertainty evaluation by kurtosis method at calibration of electrical resistance standards using a comparator

被引:0
|
作者
Zakharov, I [1 ,2 ]
Botsiura, O. [2 ]
Semenikhin, V [1 ]
机构
[1] Natl Sci Ctr, Inst Metrol, Myronosytska Str 42, UA-61002 Kharkiv, Ukraine
[2] Kharkiv Natl Univ Radio Elect, Nauky Ave 14, UA-61166 Kharkiv, Ukraine
来源
UKRAINIAN METROLOGICAL JOURNAL | 2020年 / 01期
关键词
electrical resistance standard; resistance comparator; calibration; measurement uncertainty; uncertainty budget; kurtosis method; Monte-Carlo method;
D O I
暂无
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The article provides examples of the application of electrical resistance standards in metrological practice. Existing methods for their calibration are analyzed. It is established that calibration using a comparator is the most accurate and common method for calibrating electrical resistance standards. A model for transferring the size of the resistance unit in calibration of electrical resistance standards using a comparator is considered. An expression is given for the evaluation of the value of measurand. The procedure for estimating the expanded measurement uncertainty based on the kurtosis method is described, and the uncertainty budget is drawn up. An example of evaluation of the measurement uncertainty in calibration of the resistance coil P321 using a resistance comparator P3015 is given. The coincidence of the obtained results with those got using the Monte Carlo method is shown.
引用
收藏
页码:12 / 16
页数:5
相关论文
共 50 条
  • [31] Numerical simulation for the determination of the measurement uncertainty for the calibration of mass standards by transfer artefacts
    Lehrmann, Katharina
    Haertig, Frank
    Tutsch, Rainer
    TM-TECHNISCHES MESSEN, 2021, 88 (02) : 90 - 102
  • [32] Validation of the GUM using the Monte Carlo method when applied in the calculation of the measurement uncertainty of a compact prover calibration
    Castro, H. F. F.
    FLOW MEASUREMENT AND INSTRUMENTATION, 2021, 77
  • [33] Evaluation of uncertainty of measurement in calibration of electrostatic voltmeter - A case study
    Jaiswal, SK
    Gupta, SR
    Sridhar, L
    Singh, D
    JOURNAL OF SCIENTIFIC & INDUSTRIAL RESEARCH, 2003, 62 (12): : 1176 - 1180
  • [34] Calibration and Uncertainty Evaluation of a Measurement System Using MLE: Application to a U-Bent RI POF-Sensor
    Quintans Grana, Camilo
    Valdes Pena, Maria Dolores
    Cao y Paz, Ana Maria
    Moure Rodriguez, Maria Jose
    Marcos Acevedo, Jorge
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2021, 70
  • [35] Uncertainty Evaluation and Validation of a Comparison Methodology to Perform In-house Calibration of Platinum Resistance Thermometers using a Monte Carlo Method
    A. Silva Ribeiro
    J. Alves e Sousa
    C. Oliveira Costa
    M. Pimenta Castro
    M. G. Cox
    International Journal of Thermophysics, 2008, 29 : 902 - 914
  • [36] Evaluation of measurement uncertainty for a high-precision angle comparator with a vacuum preloaded structure
    Xia, Yangqiu
    Wu, Zhilin
    Huang, Ming
    Li, Mengyang
    Tang, Qiang
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2020, 31 (02)
  • [37] Uncertainty evaluation and validation of a comparison methodology to perform in-house calibration of platinum resistance thermometers using a Monte Carlo Method
    Ribeiro, A. Silva
    Alves e Sousa, J.
    Costa, C. Oliveira
    Castro, M. Pimenta
    Cox, M. G.
    INTERNATIONAL JOURNAL OF THERMOPHYSICS, 2008, 29 (03) : 902 - 914
  • [38] On a Monte Carlo method for measurement uncertainty evaluation and its implementation
    Harris, P. M.
    Cox, M. G.
    METROLOGIA, 2014, 51 (04) : S176 - S182
  • [39] Evaluation of the measurement uncertainty: Some common mistakes with a focus on the uncertainty from linear calibration
    Kadis, Rouvim
    JOURNAL OF CHROMATOGRAPHY A, 2017, 1499 : 226 - 229
  • [40] Analytical estimation of measurement uncertainty in surface plate calibration by the Moody method using differential levels
    Drescher, J
    PRECISION ENGINEERING-JOURNAL OF THE INTERNATIONAL SOCIETIES FOR PRECISION ENGINEERING AND NANOTECHNOLOGY, 2003, 27 (03): : 323 - 332