Efficacy of localization of non-palpable, invasive breast cancer: Wire localization vs. Iodine-125 seed: A historical comparison

被引:7
作者
in't Hout, B. A. [1 ]
Schenk, K. E. [1 ]
van der Linden, A. N. [2 ]
Roumen, R. M. H. [1 ,3 ]
机构
[1] Maxima Med Ctr, Dept Surg, POB 7777, NL-5500 MB Veldhoven, Netherlands
[2] Maxima Med Ctr, Dept Radiol, POB 7777, NL-5500 MB Veldhoven, Netherlands
[3] Maastricht Univ, Med Ctr, Sch GROW, POB 616, NL-6200 MD Maastricht, Netherlands
关键词
Breast cancer; Iodine-125; seed; Wire localization; OCCULT LESION LOCALIZATION; RADIOACTIVE SEED; CONSERVING SURGERY; METAANALYSIS; LUMPECTOMY; BIOPSY; TRIAL;
D O I
10.1016/j.breast.2016.06.011
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background: To achieve radical tumour excision in non-palpable breast cancer accurate tumour localization is essential. Historically, this has been achieved by wire localization (WL). Recently, new techniques like Iodine-125 seeds (IL) have become available. The aim of this study was to determine whether the results in case of IL are better than when WL is used. Method: A consecutive series of patients operated on because of don-palpable breast cancer was analysed. Between January 2007 and April 2011 WL was method of choice. From April 2011 till January 2013 IL was introduced and became the standard procedure. Primary outcomes were: success rate of (peri-) operative localization and radicality of the excision. Secondary outcomes were duration of operation and volumes of the excised tissue specimen. Results: A total of 236 women were included; 149 women underwent WL and 87 women IL. The overall success rate for WL was 93.3%. In 10 patients (6.7%) WL failed because of peri-operative dislocation of the wire compared to only one failure to locate the seed in de postoperative specimen in the IL-group (1.1%, p = 0.098). Radical resection was obtained in 126/149 (84.6%) of the WL-patients, in comparison with 81/87 (93.1%) in the IL-group (p = 0.054). Median operation time and volume of the specimen was not significantly different between both groups. Conclusion: Localization of non-palpable breast cancer using Iodine-125 seeds is, at least, as good as the standard wire localization procedure. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:8 / 13
页数:6
相关论文
共 20 条
  • [1] Radioactive seed localisation (RSL) in the treatment of non-palpable breast cancers: Systematic review and meta-analysis
    Ahmed, M.
    Douek, M.
    [J]. BREAST, 2013, 22 (04) : 383 - 388
  • [2] Radioactive Seed Localization of Breast Lesions: An Adequate Localization Method without Seed Migration
    Alderliesten, Tanja
    Loo, Claudette E.
    Pengel, Kenneth E.
    Rutgers, Emiel J. Th.
    Gilhuijs, Kenneth G. A.
    Peeters, Marie-Jeanne T. F. D. Vrancken
    [J]. BREAST JOURNAL, 2011, 17 (06) : 594 - 601
  • [3] Positive margin rates following breast-conserving surgery for stage I-III breast cancer: palpable versus nonpalpable tumors
    Atkins, Jordan
    Al Mushawah, Fatema
    Appleton, Catherine M.
    Cyr, Amy E.
    Gillanders, William E.
    Aft, Rebecca L.
    Eberlein, Timothy J.
    Gao, Feng
    Margenthaler, Julie A.
    [J]. JOURNAL OF SURGICAL RESEARCH, 2012, 177 (01) : 109 - 115
  • [4] Radioactive seed localization for non-palpable breast cancer
    Barentsz, M. W.
    van den Bosch, M. A. A. J.
    Veldhuis, W. B.
    van Diest, P. J.
    Pijnappel, R. M.
    Witkamp, A. J.
    Verkooijen, H. M.
    [J]. BRITISH JOURNAL OF SURGERY, 2013, 100 (05) : 582 - 588
  • [5] Cady B, 1996, ARCH SURG-CHICAGO, V131, P301
  • [6] Wire-guided Localization Biopsy to Determine Surgical Margin Status in Patients with Non-palpable Suspicious Breast Lesions
    Dogan, Lutfi
    Gulcelik, M. Ali
    Yuksel, Murat
    Uyar, Osman
    Reis, Erhan
    [J]. ASIAN PACIFIC JOURNAL OF CANCER PREVENTION, 2012, 13 (10) : 4989 - 4992
  • [7] Strategies for localisation of impalpable breast lesions
    Du, Sascha Miles
    Gray, Richard J.
    Keshtgar, Mohammed
    [J]. BREAST, 2011, 20 (03) : 246 - 253
  • [8] Fracheboud J, 1998, INT J CANCER, V75, P694, DOI 10.1002/(SICI)1097-0215(19980302)75:5<694::AID-IJC6>3.0.CO
  • [9] 2-U
  • [10] PREOPERATIVE LOCALIZATION OF NON-PALPABLE BREAST LESIONS DEMONSTRATED BY MAMMOGRAPHY
    FRANK, HA
    HALL, FM
    STEER, ML
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1976, 295 (05) : 259 - 260