Inline Real-Time Near-Infrared Granule Moisture Measurements of a Continuous Granulation-Drying-Milling Process

被引:69
|
作者
Chablani, Lipika [1 ,2 ]
Taylor, Michael K. [3 ]
Mehrotra, Amit [4 ]
Rameas, Patrick [5 ]
Stagner, William C. [1 ]
机构
[1] Campbell Univ, Dept Pharmaceut Sci, Coll Pharm & Hlth Sci, Buies Creek, NC 27506 USA
[2] Mercer Univ, Grad Program, Coll Pharm & Hlth Sci, Atlanta, GA USA
[3] BioDelivery Sci, Raleigh, NC USA
[4] GlaxoSmithKline Inc, Pharma Launch & Global Supply, Zebulon, NC USA
[5] GlaxoSmithKline Inc, Pharmaceut Dev, Res Triangle Pk, NC USA
来源
AAPS PHARMSCITECH | 2011年 / 12卷 / 04期
关键词
continuous granulation-drying-milling; near-infrared (NIR) spectroscopy; process analytical technology (PAT); real-time moisture determination; NIR SPECTROSCOPY; POWDER; QUALITY; MONITOR; DESIGN;
D O I
10.1208/s12249-011-9669-z
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
The purpose of this research was to use inline real-time near-infrared (NIR) to measure the moisture content of granules manufactured using a commercial production scale continuous twin-screw granulator fluid-bed dryer milling process. A central composite response surface statistical design was used to study the effect of inlet air temperature and dew point on granule moisture content. The NIR moisture content was compared to Karl Fischer (KF) and loss on drying (LOD) moisture determinations. Using multivariate analysis, the data showed a statistically significant correlation between the conventional methods and NIR. The R (2) values for predicted moisture content by NIR versus KF and predicted moisture values by NIR versus LOD were 0.94 (p < 0.00001) and 0.85 (p < 0.0002), respectively. The adjusted R (2) for KF versus LOD correlation was 0.85 (p < 0.0001). Analysis of the response surface design data showed that inlet air temperature over a range of 35-55A degrees C had a significant linear impact on granule moisture content as measured by predicted NIR (adjusted R (2) = 0.84, p < 0.02), KF (adjusted R (2) = 0.91, p < 0.0001), and LOD (adjusted R (2) = 0.85, p < 0.0006). The inlet air dew point range of 10-20A degrees C did not have a significant impact on any of the moisture measurements.
引用
收藏
页码:1050 / 1055
页数:6
相关论文
共 50 条
  • [41] Evaluation of the effect of granule size of raw tableting materials on critical quality attributes of tablets during the continuous tablet manufacturing process using near-infrared spectroscopy
    Otsuka, Makoto
    Ogata, Tokiro
    Hattori, Yusuke
    Sasaki, Tetsuo
    DRUG DEVELOPMENT AND INDUSTRIAL PHARMACY, 2023, 49 (11) : 692 - 702
  • [42] Real-time and field monitoring of the key parameters in industrial trough composting process using a handheld near infrared spectrometer
    Huang, Yuanping
    Sun, Xiaoxi
    Liao, Keke
    Han, Lujia
    Yang, Zengling
    JOURNAL OF NEAR INFRARED SPECTROSCOPY, 2020, 28 (5-6) : 334 - 343
  • [43] In-situ indirect measurements of real-time moisture contents during microwave vacuum drying of beef and carrot slices using terahertz time-domain spectroscopy
    Ren, Yuqiao
    Lei, Tong
    Sun, Da-Wen
    FOOD CHEMISTRY, 2023, 418
  • [44] In-line and Real-time Monitoring of Resonant Acoustic Mixing by Near-infrared Spectroscopy Combined with Chemometric Technology for Process Analytical Technology Applications in Pharmaceutical Powder Blending Systems
    Ryoma Tanaka
    Naoyuki Takahashi
    Yasuaki Nakamura
    Yusuke Hattori
    Kazuhide Ashizawa
    Makoto Otsuka
    Analytical Sciences, 2017, 33 : 41 - 46
  • [45] Real-time monitoring of the column chromatographic process of Phellodendri Chinensis Cortex part I: end-point determination based on near-infrared spectroscopy combined with machine learning
    Wu, Sijun
    Cui, Tongcan
    Li, Zheng
    Yang, Ming
    Zang, Zhenzhong
    Li, Wenlong
    NEW JOURNAL OF CHEMISTRY, 2022, 46 (19) : 9085 - 9097
  • [46] A practical evaluation of qualitative and quantitative chemometric models for real-time monitoring of moisture content in a fluidised bed dryer using near infrared technology
    Barla, Venkata Sureshkumar
    Kumar, Rajendra
    Nalluri, Venkateshwar Rao
    Gandhi, Rahul R.
    Venkatesh, Krishna
    JOURNAL OF NEAR INFRARED SPECTROSCOPY, 2014, 22 (03) : 221 - 228
  • [47] Azo-Based Hypoxia-Responsive Self-Assembly Near-Infrared Fluorescent Nanoprobe for In Vivo Real-Time Bioimaging of Tumors
    Liu, Wangwang
    Yao, Xufeng
    Zhu, Wenchao
    Wang, Jing
    Zhou, Fangyuan
    Qian, Xiaoli
    Tiemuer, Aliya
    Yang, Shikui
    Wang, Hai-Yan
    Liu, Yi
    ACS APPLIED BIO MATERIALS, 2021, 4 (03) : 2752 - 2758
  • [48] In situ and real-time monitoring of an ultrasonic-assisted enzymatic hydrolysis process of corn gluten meal by a miniature near infrared spectrometer
    Luo, Lin
    Zhang, Yanyan
    Wang, Kai
    Ma, Haile
    Dong, Mingsheng
    ANALYTICAL METHODS, 2017, 9 (25) : 3795 - 3803
  • [49] Near-Infrared Fluorescent Probe with Remarkable Large Stokes Shift and Favorable Water Solubility for Real-Time Tracking Leucine Aminopeptidase in Living Cells and In Vivo
    Zhang, Wenda
    Liu, Feiyan
    Zhang, Chao
    Luo, Jian-Guang
    Luo, Jun
    Yu, Wenying
    Kong, Lingyi
    ANALYTICAL CHEMISTRY, 2017, 89 (22) : 12319 - 12326
  • [50] Transferring a large data library of fresh total mixed rations from a benchtop to 2 portable near-infrared spectrometers for on-farm real-time decisions
    Perez-Marin, Dolores
    de la Roza-Delgado, Begona
    Entrenas, J. Antonio
    Garrido-Cuevas, Mar
    Garrido-Varo, Ana
    JOURNAL OF DAIRY SCIENCE, 2022, 105 (03) : 2380 - 2392