Inline Real-Time Near-Infrared Granule Moisture Measurements of a Continuous Granulation-Drying-Milling Process

被引:69
|
作者
Chablani, Lipika [1 ,2 ]
Taylor, Michael K. [3 ]
Mehrotra, Amit [4 ]
Rameas, Patrick [5 ]
Stagner, William C. [1 ]
机构
[1] Campbell Univ, Dept Pharmaceut Sci, Coll Pharm & Hlth Sci, Buies Creek, NC 27506 USA
[2] Mercer Univ, Grad Program, Coll Pharm & Hlth Sci, Atlanta, GA USA
[3] BioDelivery Sci, Raleigh, NC USA
[4] GlaxoSmithKline Inc, Pharma Launch & Global Supply, Zebulon, NC USA
[5] GlaxoSmithKline Inc, Pharmaceut Dev, Res Triangle Pk, NC USA
来源
AAPS PHARMSCITECH | 2011年 / 12卷 / 04期
关键词
continuous granulation-drying-milling; near-infrared (NIR) spectroscopy; process analytical technology (PAT); real-time moisture determination; NIR SPECTROSCOPY; POWDER; QUALITY; MONITOR; DESIGN;
D O I
10.1208/s12249-011-9669-z
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
The purpose of this research was to use inline real-time near-infrared (NIR) to measure the moisture content of granules manufactured using a commercial production scale continuous twin-screw granulator fluid-bed dryer milling process. A central composite response surface statistical design was used to study the effect of inlet air temperature and dew point on granule moisture content. The NIR moisture content was compared to Karl Fischer (KF) and loss on drying (LOD) moisture determinations. Using multivariate analysis, the data showed a statistically significant correlation between the conventional methods and NIR. The R (2) values for predicted moisture content by NIR versus KF and predicted moisture values by NIR versus LOD were 0.94 (p < 0.00001) and 0.85 (p < 0.0002), respectively. The adjusted R (2) for KF versus LOD correlation was 0.85 (p < 0.0001). Analysis of the response surface design data showed that inlet air temperature over a range of 35-55A degrees C had a significant linear impact on granule moisture content as measured by predicted NIR (adjusted R (2) = 0.84, p < 0.02), KF (adjusted R (2) = 0.91, p < 0.0001), and LOD (adjusted R (2) = 0.85, p < 0.0006). The inlet air dew point range of 10-20A degrees C did not have a significant impact on any of the moisture measurements.
引用
收藏
页码:1050 / 1055
页数:6
相关论文
共 50 条
  • [1] Inline Real-Time Near-Infrared Granule Moisture Measurements of a Continuous Granulation–Drying–Milling Process
    Lipika Chablani
    Michael K. Taylor
    Amit Mehrotra
    Patrick Rameas
    William C. Stagner
    AAPS PharmSciTech, 2011, 12 : 1050 - 1055
  • [2] Real-Time Particle Size Analysis Using Focused Beam Reflectance Measurement as a Process Analytical Technology Tool for a Continuous Granulation-Drying-Milling Process
    Kumar, Vijay
    Taylor, Michael K.
    Mehrotra, Amit
    Stagner, William C.
    AAPS PHARMSCITECH, 2013, 14 (02): : 523 - 530
  • [3] Development of Inline Near-Infrared Spectroscopy Method for Real-Time Monitoring of Blend Uniformity of Direct Compression and Granulation-Based Products at Commercial Scales
    Khanolkar, Aruna
    Patil, Bhaskar
    Thorat, Viraj
    Samanta, Gautam
    AAPS PHARMSCITECH, 2022, 23 (07)
  • [4] Real-time monitoring of integrated continuous granulation/drying line system " LaVortex ®" for the pharmaceutical manufacturing of acetaminophen oral dosage formulations using near-infrared spectroscopy
    Koyanagi, Keita
    Shoji, Kippei
    Ueno, Akinori
    Sasaki, Tetsuo
    Otsuka, Makoto
    JOURNAL OF DRUG DELIVERY SCIENCE AND TECHNOLOGY, 2024, 101
  • [5] Real-time monitoring of granule properties during high shear wet granulation by near-infrared spectroscopy with a chemometrics approach
    Shikata, F.
    Kimura, S.
    Hattori, Y.
    Otsuka, M.
    RSC ADVANCES, 2017, 7 (61): : 38307 - 38317
  • [6] Real-Time Particle Size Analysis Using Focused Beam Reflectance Measurement as a Process Analytical Technology Tool for a Continuous Granulation–Drying–Milling Process
    Vijay Kumar
    Michael K. Taylor
    Amit Mehrotra
    William C. Stagner
    AAPS PharmSciTech, 2013, 14 : 523 - 530
  • [7] Real-Time Monitoring of Yogurt Fermentation Process by Aquaphotomics Near-Infrared Spectroscopy
    Muncan, Jelena
    Tei, Kyoko
    Tsenkova, Roumiana
    SENSORS, 2021, 21 (01) : 1 - 18
  • [8] Real-time process monitoring in a semi-continuous fluid-bed dryer - microwave resonance technology versus near-infrared spectroscopy
    Peters, Johanna
    Teske, Andreas
    Taute, Wolfgang
    Doescher, Claas
    Hoeft, Michael
    Knoechel, Reinhard
    Breitkreutz, Joerg
    INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2018, 537 (1-2) : 193 - 201
  • [9] Development of Inline Near-Infrared Spectroscopy Method for Real-Time Monitoring of Blend Uniformity of Direct Compression and Granulation-Based Products at Commercial Scales
    Aruna Khanolkar
    Bhaskar Patil
    Viraj Thorat
    Gautam Samanta
    AAPS PharmSciTech, 23
  • [10] Real-time assessment of critical quality attributes of a continuous granulation process
    Fonteyne, Margot
    Vercruysse, Jurgen
    Cordoba Diaz, Damian
    Gildemyn, Delphine
    Vervaet, Chris
    Remon, Jean Paul
    De Beer, Thomas
    PHARMACEUTICAL DEVELOPMENT AND TECHNOLOGY, 2013, 18 (01) : 85 - 97