A method to compensate non-damage-related influences on Damage Indices used for pitch-catch scheme of piezoelectric transducer based Structural Health Monitoring

被引:6
作者
Dragan, Krzysztof [1 ]
Dziendzikowski, Michal [1 ]
机构
[1] Air Force Inst Technol, Ul Ks Boleslawa 6, PL-01494 Warsaw, Poland
来源
STRUCTURAL HEALTH MONITORING-AN INTERNATIONAL JOURNAL | 2016年 / 15卷 / 04期
关键词
Lamb waves; compensation methods for guided waves; damage detection; fatigue cracks growth monitoring; Damage Indices' compensation; LAMB WAVES; IDENTIFICATION; COMPOSITES; STABILITY; NETWORK;
D O I
10.1177/1475921716643492
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The risk of false calls of structural health monitoring systems is as much important for their application as their damage detection capabilities. Structural health monitoring based on guided waves propagation is particularly vulnerable to false calls. Signals acquired for piezoelectric transducer networks can be changed by many factors other than damage, for example, environmental factors or those related to the transducers' aging or degradation of the transducers' bonding with the monitored structure. A lot of studies were devoted to examine non-damage-related influences on structural health monitoring systems based on Lamb waves and to compensate the undesired effects. Most of compensation methods act on the level of the signal, that is, for a given factor influencing performance of piezoelectric transducers, signals are transformed to match the corresponding baselines. After such compensation procedure, the Damage Indices are calculated for the purpose of damage detection. In order to compensate the impact of all of non-damage-related factors, all of them need to be, at least, recognized. In this article, a different technique to compensate changes of Damage Indices values caused by factors other than damage is proposed. The method does not involve any operation on signals, but on the Damage Indices themselves. The factors causing Damage Indices' changes neither have to be measured nor are even known. The capabilities of the method have been evaluated on the example of fatigue cracks detection in laboratory specimen tests and using results obtained during Full-Scale Fatigue Test of an aircraft.
引用
收藏
页码:423 / 437
页数:15
相关论文
共 43 条
  • [1] Experimental study on identifying cracks of increasing size using ultrasonic excitation
    An, Jungeun
    Haftka, Raphael T.
    Kim, Nam H.
    Yuan, Fuh-Gwo
    Kwak, Byung Man
    Sohn, Hoon
    Yeum, Chul Min
    [J]. STRUCTURAL HEALTH MONITORING-AN INTERNATIONAL JOURNAL, 2012, 11 (01): : 95 - 108
  • [2] [Anonymous], 2009, NONDESTRUCTIVE EVALU
  • [3] ASM Handbook Committee, 1989, ASM HDB COMM ASM HDB, V17
  • [4] Long-term stability of guided wave structural health monitoring using distributed adhesively bonded piezoelectric transducers
    Attarian, Vatche A.
    Cegla, Frederic B.
    Cawley, Peter
    [J]. STRUCTURAL HEALTH MONITORING-AN INTERNATIONAL JOURNAL, 2014, 13 (03): : 265 - 280
  • [5] Chimenti D.E., 1997, Appl. Mech. Rev., V50, P247, DOI DOI 10.1115/1.3101707
  • [6] Structural health monitoring of fatigue crack growth in plate structures with ultrasonic guided waves
    Cho, Hwanjeong
    Lissenden, Cliff J.
    [J]. STRUCTURAL HEALTH MONITORING-AN INTERNATIONAL JOURNAL, 2012, 11 (04): : 393 - 404
  • [7] Guided wave health monitoring of complex structures by sparse array systems: Influence of temperature changes on performance
    Clarke, T.
    Simonetti, F.
    Cawley, P.
    [J]. JOURNAL OF SOUND AND VIBRATION, 2010, 329 (12) : 2306 - 2322
  • [8] Efficient temperature compensation strategies for guided wave structural health monitoring
    Croxford, Anthony J.
    Moll, Jochen
    Wilcox, Paul D.
    Michaels, Jennifer E.
    [J]. ULTRASONICS, 2010, 50 (4-5) : 517 - 528
  • [9] Thermal sensitivity of Lamb waves for structural health monitoring applications
    Dodson, J. C.
    Inman, D. J.
    [J]. ULTRASONICS, 2013, 53 (03) : 677 - 685
  • [10] Dragan K, 2014, P 7 EUR WORKSH STRUC